55A6051 SPECIFICATION CONTROL DRAWING Date Revision TITLE TWO CONDUCTOR CABLE, SHIELDED, JACKETED B 10-28-03 This specification sheet forms a part of the latest issue of Raychem Specification 55A. COMPONENT WIRES - 55A0814 SHIELD - SILVER-COATED COPPER JACKET - RADIATION-CROSSLINKED, MODIFIED ETFE CABLE CONSTRUCTION DETAILS CONDUCTOR SHIELD JACKET THICKNESS OUTSIDE DIAMETER MAXIMUM PART NUMBER (inch) SIZE SIZE (inch) WEIGHT 1/ (AWG) (lb/1000 ft) (AWG) MINIMUM MAXIMUM MAXIMUM NOMINAL 55A6051-26-* 26 38 .005 .010 .113 .119 9.6 55A6051-24-* 24 38 .005 .123 .129 11.4 .010 55A6051-22-* 22 38 .005 .010 .133 .141 14.1 55A6051-20-* 20 38 .005 .149 .158 18.2 .010 CABLE RATINGS AND ADDITIONAL REQUIREMENTS LOW TEMPERATURE-COLD BEND: -55 5C for 4 hours TEMPERATURE RATING: 200C SHIELD COVERAGE: 85% (minimum) Maximum continuous conductor temperature VOLTAGE WITHSTAND TEST (Post Environmental): VOLTAGE RATING: 600 volts (rms) at sea level 1000 volts (rms), 60 Hz, 1 minute BLOCKING: 200 3C for 6 hours CROSSLINK VERIFICATION: 300 5C for 6 hours DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz PART NUMBER: FLAMMABILITY: Procedure 1, The in the part numbers above shall be replaced 3 seconds (maximum) 3 in. (maximum) by color code designators with a slash separating no flaming of facial tissue the component wire colors and a dash separating JACKET COLOR: White preferred the component wire colors from the jacket color. JACKET ELONGATION AND TENSILE STRENGTH: 1/ Example: AWG 20, white and white with blue stripe wires Elongation, 50% (minimum) white jacket: 55A6051-20-9/96-9 Tensile Strength, 5000 lbf/in (minimum) JACKET FLAWS: Spark Test, 1.5 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) This cable shall meet all constructional requirements of M27500 (AWGSE2S23). Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. R Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Phone: 1-800-227-8816 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Fax: 1-650-361-6297