55AC1122 SPECIFICATION CONTROL DRAWING Title Date Revision TWO CONDUCTOR CABLE, SHIELDED, JACKETED, 600 VOLT 7-18-03 A This specification sheet forms a part of the latest issue of Raychem Specification 55A. COMPONENT WIRES 55A0112 SHIELD SILVER-COATED COPPER JACKET - RADIATION-CROSSLINKED, MODIFIED ETFE CABLE CONSTRUCTION DETAILS JACKET THICKNESS OUTSIDE DIAMETER CONDUCTOR SHIELD MAXIMUM PART NUMBER (in.) (in.) SIZE SIZE WEIGHT 1/ (AWG) (AWG) (lb/1000 ft) MINIMUM NOMINAL NOMINAL MAXIMUM 55AC1122-28-* 28 38 .006 .008 .087 .092 6.6 55AC1122-26-* 26 38 .006 .008 .097 .102 8.3 55AC1122-24-* 24 38 .006 .008 .107 .112 10.2 55AC1122-22-* 22 38 .006 .008 .119 .125 12.7 55AC1122-20-* 20 38 .006 .008 .133 .140 16.7 55AC1122-18-* 18 38 .006 .008 .153 .161 22.6 55AC1122-16-* 16 38 .006 .008 .169 .177 27.3 55AC1122-14-* 14 38 .006 .008 .203 .213 39.3 55AC1122-12-* 12 38 .007 .009 .241 .253 56.1 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C LIFE CYCLE: 230 3C for 500 hours Maximum continuous conductor temperature LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours VOLTAGE RATING: 600 volts (rms) at sea level SHIELD COVERAGE: 90% (minimum) ACCELERATED AGING: 300 3C for 7 hours VOLTAGE WITHSTAND TEST (Post Environmental): BLOCKING: 200 3C for 6 hours 1000 volts (rms), 60 Hz, 1 minute DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz FLAMMABILITY: Procedure 1, 3 seconds (maximum) 3 inches (maximum) PART NUMBER: no flaming of facial tissue The in the part numbers above shall be replaced by color JACKET COLOR: White preferred code designators with a slash separating the component JACKET ELONGATION AND TENSILE STRENGTH: wire colors and a dash separating the component wire colors Elongation, 50% (minimum) from the jacket color. Tensile Strength, 5000 lbf/in (minimum) 1/ Example: AWG 22, blue and white component wires JACKET FLAWS: white jacket: 55AC1122-22-6/9-9 Spark Test, 1000 volts (rms) Impulse Dielectric Test, 6.0 kV (peak) NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902.. MAY BE REPLACED BYAxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Wire & Cable DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Phone: 1-800-227-8816 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Fax: 1-650-361-6297 X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 89504-002-1000 89705-008-500 CS2885-000 M27500-20SP2S23 6309UE-877-1000 M3905-BK005 6502FE 8771000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9- 9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000 83318E-009-500 8348-060-500 83559-002-1000 83653-002-5000 8404-060-500 8469 060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100 8747-060-1000 8769- 060-1000 8775-060-500 8780-060-1000 8782-001-U1000 9159-060-500 9318-060-1000 939870-000 9423 060U500 9444 060U1000 9497 0001000 9520-060-1000 9524-060-1000 9546-060-500 9572-002-U500 9774-060-1000 A43962-000 1232A1-008-1000 1302110032