SPECIFICATION CONTROL DRAWING 55PC1111
Date
Revision
TITLE
ONE CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT 9-19-13 B
This speci cation sheet forms a part of the latest issue of Raychem Speci cation 55PC.
COMPONENT WIRE - 55PC0111 SHIELD - TIN-COATED COPPER
JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
CABLE CONSTRUCTION DETAILS
JACKET THICKNESS OUTSIDE DIAMETER WEIGHT
(inch) (inch) (lbs/1000 ft.)
CONDUCTOR SHIELD
PART NUMBER
SIZE SIZE
LOWER LOWER UPPER UPPER
1/
TARGET TARGET TARGET
(AWG) (AWG)
SPEC SPEC SPEC SPEC
WALL VALUE VALUE
LIMIT LIMIT LIMIT LIMIT
55PC1111-26-* 26 38 .0050 .0060 .056 .060 .064 4.00 4.24
55PC1111-24-* 24 38 .0050 .0060 .061 .065 .069 4.86 5.12
55PC1111-22-* 22 38 .0050 .0060 .068 .071 .074 6.13 6.41
55PC1111-20-* 20 38 .0050 .0060 .075 .079 .083 8.07 8.37
55PC1111-18-* 18 38 .0050 .0060 .085 .088 .092 10.82 11.22
55PC1111-16-* 16 38 .0050 .0060 .092 .096 .100 13.03 13.46
55PC1111-14-* 14 38 .0050 .0060 .107 .110 .114 18.34 18.85
55PC1111-12-* 12 38 .0050 .0065 .126 .130 .134 26.47 27.15
55PC1111-10-* 10 38 .0050 .0065 .151 .157 .162 39.82 41.05
55PC1111-8-* 8 38 .0060 .0075 .213 .220 .227 71.34 73.35
Users should evaluate the suitability of this product for their application. Speci cations are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any speci cation, without noti cation to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx). OTHER CODES
AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Raychem Wire & Cable
501 Oakside Avenue
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
Redwood City, CA 94063-3800
Page 1 of 2
Phone: 1-800-227-8816
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
Fax: 1-650-361-6297
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
2013 Tyco Electronics Corporation. All rights reserved.Revision
Page SCD
2 of 2 B
55PC1111
SPECIFICATION CONTROL DRAWING
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CROSSLINK VERIFICATION: 300 3C for 1 hour
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in (minimum)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute
1/ PART NUMBER:
The in the part numbers on page 1 shall be replaced by color code designators
with a dash separating the component wire color from the jacket color.
Example: AWG 22, white component wire; white jacket:
55PC1111-22-9-9
1/ See footer section on page 1