SPECIFICATION CONTROL DRAWING 55PC6000 Date Revision TITLE TWO CONDUCTOR CABLE, DOUBLE SHIELDED, DOUBLE JACKETED, GENERAL PURPOSE, 600 VOLT 5-15-13 E This specification sheet forms a part of the latest issue of Raychem Specification 55PC. JACKETS - RADIATION-CROSSLINKED, COMPONENT WIRES - 55PC0211 SHIELDS - TIN-COATED COPPER MODIFIED ETFE CABLE CONSTRUCTION DETAILS st nd 1 JACKET 2 JACKET OUTSIDE DIAMETER WEIGHT st nd 1 2 THICKNESS ( in. ) THICKNESS ( in. ) ( in. ) ( lbs/1000 ft. ) CONDUCTOR PART NUMBER SHIELD SHIELD SIZE LOWER LOWER LOWER UPPER UPPER 1/ SIZE SIZE TARGET TARGET TARGET TARGET (AWG) SPEC SPEC SPEC SPEC SPEC (AWG) (AWG) WALL WALL VALUE VALUE LIMIT LIMIT LIMIT LIMIT LIMIT 55PC6000-24-* 24 38 .0050 .0065 38 .0055 .0070 .136 .141 .147 16.70 17.35 55PC6000-22-* 22 38 .0055 .0070 38 .0055 .0070 .148 .154 .160 20.12 20.84 55PC6000-20-* 20 38 .0055 .0070 38 .0060 .0075 .166 .172 .178 25.22 26.01 55PC6000-18-* 18 38 .0055 .0070 38 .0060 .0075 .185 .191 .197 31.89 32.82 55PC6000-16-* 16 38 .0060 .0075 38 .0060 .0075 .201 .207 .213 37.45 38.46 55PC6000-14-* 14 38 .0060 .0075 38 .0060 .0080 .232 .238 .245 50.30 51.48 55PC6000-12-* 12 38 .0060 .0080 38 .0065 .0085 .271 .278 .285 69.20 70.68 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Redwood City, CA 94063-3800 Page 1 of 2 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2006-2013 Tyco Electronics Corporation,. All rights reserved.SCD Revision Page 2 of 2 E 55PC6000 SPECIFICATION CONTROL DRAWING CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level CROSSLINK VERIFICATION: 300 3C for 1 hour DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz conductor to conductor and shield 500 volts (rms), 60 Hz shield to shield JACKET COLOR: White preferred JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 50% (minimum) (each) Tensile Strength, 5000 lbf/in (minimum) (each) JACKET FLAWS: Spark Test, 1000 volts (rms) Impulse Dielectric Test, 6.0 kV (peak) SHIELD COVERAGE: 85% (minimum) (each) VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute CABLE IDENTIFICATION: Mark outer jacket surface in a contrasting color at 12 inch (nominal) intervals as follows: 55PC6000-AWG ** ** = Applicable Manufacturer CAGE code as follows: 06090 = Menlo Park, CA SU473 = Tijuana, MX PART NUMBER: The in the part numbers on page 1 shall be replaced by color code designators with a slash separating the component wire colors and a dash separating the component wire colors from the inner jacket color and a dash separating the inner jacket color from the outer jacket color. 1/ Example: AWG 22, red and blue component wires white inner jacket and white outer jacket: 55PC6000-22-2/6-9-9 1/ See footer section on page 1