55PC6173 SPECIFICATION CONTROL DRAWING Date Revision TITLE THREE CONDUCTOR CABLE, DOUBLE SHIELDED, JACKETED, 600 VOLT 01-24-01 A This specification sheet forms a part of the latest issue of Raychem Specification 55PC. SHIELDS - NICKEL-COATED COPPER COMPONENT WIRES - 55PC0213 JACKET - RADIATION-CROSSLINKED, MODIFIED ETFE CONSTRUCTION DETAILS JACKET THICKNESS DIAMETER WEIGHT INNER OUTER CONDUCTOR ( in.) ( lbs/1000 ft. ) (in.) PART NUMBER SHIELD SHIELD SIZE SIZE SIZE LOWER SPEC TARGET LOWER SPEC TARGET UPPER SPEC TARGET UPPER SPEC (AWG) (AWG) (AWG) LIMIT WALL LIMIT VALUE LIMIT LIMIT VALUE 55PC6173-24-* 38 38 .0060 .0075 .131 .136 .141 18.19 18.86 24 55PC6173-22-* 38 .0060 .0075 .144 .149 22.44 22 38 .154 23.16 55PC6173-20-* 38 38 .0060 .0080 .164 .169 .174 29.16 29.98 20 55PC6173-18-* 38 38 .0060 .0080 .184 .189 .194 38.20 39.21 18 55PC6173-16-* 38 .0060 .0080 .200 .205 .210 45.43 46.52 16 38 55PC6173-14-* 38 38 .0060 .0080 .232 .238 .244 62.82 64.19 14 55PC6173-12-* 38 .0065 .0085 .274 .280 88.60 12 38 .286 90.39 55PC6173-10-* 36 36 .0070 .0090 .334 .342 .350 137.46 140.22 10 55PC6173-8-* 36 34 .0070 .0090 .477 .488 .499 239.60 248.06 8 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C VOLTAGE WITHSTAND TEST (POST ENVIRONMENTAL): Maximum continuous conductor temperature 1000 volts (rms), 60 Hz, 1 minute VOLTAGE RATING: 600 volts (rms) DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz PART NUMBER: CROSSLINKING PROOF TEST: 300 3C for 1 hour The in the part numbers above shall be replaced by color code JACKET COLOR: White preferred designators with a slash separating the component wire colors and a dash JACKET ELONGATION AND TENSILE STRENGTH: separating the component wire colors from the jacket color. Elongation, 50% (minimum) Example: AWG 22, red, blue and yellow component wires white Tensile Strength, 5000 lbf/in (minimum) jacket: 55PC6173-22-2/6/4-9 JACKET FLAWS: Spark Test, 1000 volts (rms), 100% test Impulse Dielectric Test, 6.0 kV (peak), 100 % test SHIELD COVERAGE: 85% (minimum) (each) COLOR AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. R 300 Constitution Drive, Menlo Park, California 94025 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED Page 1 of 1 1-800-2 Raychem Fax: 1-650-361-6297 DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 89182-010-1000 6000FE-877-1000 M27500-20SP2S23 6300FE-877-U1000 6309UE-877-1000 6502FE 8771000 6541PA-008-U1000 CV6807-000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4- 9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 82841-877-5000 8348-060-500 83559-002-1000 83653-002- 5000 83659-002-1000 83709-002-1000 8404-060-500 8469 060100 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060- 100 8747-060-1000 8769-060-1000 8775-060-500 877541-000 8780-060-1000 88444-002-1000 9159-060-500 939870-000 9423 060U500 9444 060U1000 9497 0001000 9515-060-1000 9520-060-1000 9524-060-1000 9546-060-500 9572-002-U500 9774-060-1000 1213F-D15- A1000 1213F-009-A1000