General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RT1
n
1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
n
DC or AC coil
n
5kV/10mm coil-contact, reinforced insulation
n
Ambient temperature 85C (DC coil)
n
WG version: product in accordance to IEC 60335-1
n
Reflow version: for THR (Through-Hole Reflow) soldering process
Typical applications
F0144-C
Boiler control, timers, garage door control, POS automation, interface
modules
Zb
Approvals Contact Data (continued)
VDE Cert. No. 40007571, cULus E214025, cCSAus 1142018; Mechanical endurance
6
CQC in preparation DC coil >30x10 operations
6
Technical data of approved types on request AC coil >10x10 operations
6
AC coil, reflow version >5x10 operations
Contact Data 12A 16A
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage 250VAC Coil Data
Max. switching voltage 400VAC Coil voltage range, DC coil/ AC coil 5 to 110VDC / 24 to 230VAC
Rated current 12A 16A Operative range, IEC 61810 2
Limiting continuous current 12A 16A, UL: 20A Coil insulation system according UL class F
Limiting making current
max. 4s, duty factor 10% 25A 30A Coil versions, DC coil
Breaking capacity max. 3000VA 4000VA Coil Rated Operate Release Coil Rated coil
Contact material AgNi 90/10, AgNi 90/10 gold plated code voltage voltage voltage resistance power
2)
Frequency of operation, with/without load VDC VDC VDC 10% mW
-1
DC coil 360/72000h 005 5 3.5 0.5 62 403
-1
AC coil 360/36000h 006 6 4.2 0.6 90 400
Operate/release time max., DC coil 8/6ms 009 9 6.3 0.9 200 400
Bounce time max., DC coil, form A/form B 4/6ms 012 12 8.4 1.2 360 400
1)
Electrical endurance see electrical endurance graph 020 20 14.0 2.0 952 420
024 24 16.8 2.4 1440 400
Contact ratings
048 48 33.6 4.8 5520 417
Type Contact Load Cycles
2)
060 60 42.0 6.0 8570 420
IEC 61810
3 2)
110 110 77.0 11.0 28800 420
RT314 DC-coil A (NO) 16A, 250VAC, cos=1, 85C 30x10
3
2) Coil resistance 12%.
RT314 DC-coil C (CO) 16A, 250VAC, cos=1, 85C 10x10
3
All figures are given for coil without pre-energization, at ambient temperature +23C.
RT314 DC-coil A (NO) 10A, 400VAC, cos=1, 85C 150x10
3 Other coil voltages on request.
RT114 DC-coil A (NO) 12A, 250VAC, cos=1, 85C 50x10
3
RT114 AC-coil A (NO) 12A, 250VAC, cos=1, 70C 100x10 Coil versions, AC coil 50/60 Hz
UL 508 Coil Rated Operate Release Coil Rated coil
3
RT314 A/B (NO/NC) 20A, 250VAC, general purpose, 85C 6x10 code voltage voltage voltage resistance power
3 3)
RT334 A (NO) 16A, 250VAC, gen. purpose, 85C 50x10 VAC VAC VAC 15% VA
3 3)
RT314 A (NO) 1hp, 240VAC, 40C 1x10 524 24 18.0 3.6 350 0.76
3
RT314 A (NO) FLA/LRA, 4.5/13.1A, 480VAC, 70C 100x10 615 115 86.3 17.3 8100 0.76
EN60947-5-1 620 120 90.0 18.0 8800 0.75
RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13 6.050 700 200 150.0 30.0 24350 0.76
EN60730-1 730 230 172.5 34.5 32500 0.74
3
3) Coil resistance 10%.
RT314 DC-coil A (NO) 12(2)A, 250VAC, 85C 100x10
1) For reflow solderable versions: actual contact performance may be influenced by the All figures are given for coil without pre-energization, at ambient temperature +23C, 50 Hz.
reflow soldering process. Other coil voltages on request.
1
10-2014, Rev. 1014 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec-
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
2014 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change.
a TE Connectivity Ltd. company General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RT1 (Continued)
Insulation Data Other Data (continued)
Initial dielectric strength Terminal type
between open contacts 1000V standard version PCB-THT, plug-in
rms
between contact and coil 5000V reflow version PCB-THR
rms
Clearance/creepage Mounting distance AC coil: 2.5mm
between contact and coil 10/10mm Weight 14g
Material group of insulation parts IIIa Resistance to soldering heat THT, IEC 60068-2-20
Tracking index of relay base PTI 250V RTII 270C/10s
reflow version PTI 175V RTIII 260C/5s
Resistance to soldering heat THR
4)
reflow soldering (for reflow version) forced gas convection or
5)
vapour phase
Other Data
temperature profile according EN61730
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
Packaging/unit tube/20 pcs., box/500 pcs.
refer to the Product Compliance Support Center at
4) infrared heating not allowed
www.te.com/customersupport/rohssupportcenter
5) recommended fluid LS/230
Resistance to heat and fire
WG version or Reflow version according EN60335, par30
Ambient temperature Accessories
DC coil -40 to 85C For details see datasheet Accessories Industrial Power Relay R T
AC coil -40 to 70C NOTE: indicated contact ratings and electrical endurance data for direct
Category of environmental protection, IEC 61810 wiring of relays (according IEC 61810-1); for relays mounted on sockets
standard version R TII - flux proof, RTIII - wash tight deratings may apply.
reflow version RTII - flux proof
Vibration resistance (functional)
form A/form B contact, 30 to 500Hz 20g/5g
Shock resistance (destructive) 100g
PCB layout / terminal assignment
*) With the recommended PCB hole sizes a grid
Bottom view on solder pins
pattern from 2.5 mm to 2.54 mm can be used.
12A, pinning 3.5mm 12 A, pinning 5 mm 16 A, pinning 5 mm
S0418-CB S0418-CN S0418-CA
1 form C (CO) contact 1 form C (CO) contact 1 form C (CO) contact
S0163-BG S0163-BC S0163-BE
1 form A (NO) contact 1 form A (NO) contact 1 form A (NO) contact
S0163-BH S0163-BD S0163-BF
2
10-2014, Rev. 1014 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec-
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
2014 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change.
a TE Connectivity Ltd. company