Signal Relays AXICOM Cradle N Relay V23154/V23162 n Multi purpose relay n Highly reliable n Great variety of contact arrangements and materials to meet specific applications n Contacts for signal loads and currents up to 5 A n DC coil, operating voltage 1.5VDC to 125VDC AC, latching and non- latching coils on request n Sockets for easy and quick mounting of relays Typical applications Measurement and control equipment, control equipment in nuclear powerplant, press controls with high safety requirements (force-guided springs), telecommunications Contact Data Product code block 3 B104/B110/B112 B604/B610/B612 C104/C110/C112 C404/C410 F104 to F107 Contact arrangement max. 4 form C (4 CO)contacts, 2 form B (2 NC) contacts or 6 form A (6 NO) contacts (see product code table) Max. switching voltage 150VDC 36VDC 150VDC 36VDC 150VDC 125VAC 30VAC 125VAC 30VAC 125VAC Rated current 2A 0.2A 2A 0.2A 5A Limiting continuous current at max. ambient temperature 2A 2A 2A 2A 5A Breaking capacity max. 35 to 70W 5W, 5VA 35 to 70W 5W, 5VA 50 to 140W see DC load breaking capacity curve below 50VA - 50VA - 500VA Contact material silver, gold-flashed gold F silver, gold-flashed gold F silver, gold-flashed Contact style single contact single contact bifurcated contacts bifurcated contacts single contact Frequency of operation, without load, max. 50 ops./s 50 ops./s 50 ops./s 50 ops./s 10 ops./s Operate / release time typ. 7.5/3ms 7.5/3ms 7.5/3ms 7.5/3ms 7.5/3ms 7 7 7 7 7 Mechanical endurance app. 10 ops. app. 10 ops. app. 10 ops. app. 10 ops. app. 10 ops. Max. DC breaking capacity, contact sets B1xx, C1xx Max. DC breaking capacity, contact sets F1xx 150 250 V V 200 120 140 W U U 70 W 150 100 100 W 100 80 80 60 60 50 50 safe breaking, no stationary arc 40 contact material Ag, gold flashed safe breaking, no stationary arc 40 contact material Ag, gold flashed 50 W 40 W 30 30 20 0,3 0,4 0,5 0,6 0,8 1 1,5 2A 0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 4 5A I DC current A DC current A I 1 07-2012, Rev. 0712 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company Signal Relays AXICOM Cradle N Relay V23154/V23162 (Continued) Coil Data Coil data (continued) Magnetic system neutral Coil voltage range 1.1 to 125 VDC, Terminals: typ. 800mW power consumption coil with 1 winding: start 4, end 1 Max. coil temperature 100 C coil with 2 windings (upon request): Thermal resistance < 50K/W start 3, end 2 for winding I, start 4, end 1 for winding II Coil versions, DC coil, monostable The minimum voltage U depends on the contact set and the ambient I Coil Rated Operate/Limiting Coil Rated coil temperature, the maximum voltage U only depends on the ambient II 1) code voltage voltage resistance power temperature. VDC VDC 15% mW Between minimum voltage U and operating voltage U a safety margin I tamb 702 1.1 - 2 807 of approx. 20% is recommended. 711 5 - 28 893 712 7 - 58 845 U (1.2) < U U tamb I tamb I II 715 9 - 110 736 U U U20 C k I tamb I I tamb 716 10 - 150 667 U U 20 C k II tamb Il II tamb 717 12 - 220 655 tamb Ambient temperature 719 15 - 325 692 U Operating voltage 720 20 - 550 727 U Minimum voltage at ambient temperature, tamb I tamb 721 24 - 890 647 U Maximum voltage at ambient temperature, tamb II tamb 722 32 - 1700 602 k and k Factors I II 726 48 - 3200 720 734 60 - 4700 766 Insulation Data 704 72 - 7600 682 Product code, block 3 B1xx, B6xx, F1xx 735 110 - 15000 807 C1xx, C4xx 703 125 - 20900 748 Initial dielectric strength 1) refer to Part code table. between coil / frame 500V 500V rms rms All figures are given for coil without pre-energization, at ambient temperature +23C. between contact / contact 500V 1000V rms rms Coil versions, DC coil, monostable between contact / frame 500V 1000V rms rms Coil Rated Operate/Limiting Coil Rated coil between contact / coil 1000V 1500V rms rms 1) code voltage voltage resistance power Initial insulation resistance, at 500VDC > 106 VDC VDC 15% mW 430 10 - 140 714 418 12 - 230 626 Other Data 471 12 - 220 655 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 479 16 - 390 656 refer to the Product Compliance Support Center at 421 24 - 700 823 www.te.com/customersupport/rohssupportcenter 472 24 - 890 647 Ambient temperature -40 to +70C 496 25 - 730 856 Category of environmental protection 473 60 - 4700 766 IEC 61810 RT - I dust protected, 404 72 - 5800 894 RT V - hermetically sealed 1) refer to Part code table. Degree of protection, IEC 60529 dust-protected IP 30, All figures are given for coil without pre-energization, at ambient temperature +23C. hermetically sealed IP 67 Terminal type PCB, plug-in, solder terminals Weight V23154-C0/-MO Size I approx. 20g V23154-D0/-NO Size II approx. 25g V23162-A0xxx Size I approx. 30g V23162-B0xxx Size II approx. 35g Washing not recommended Ultrasonic cleaning not recommended Packaging unit 5 pcs. Accessories For details see datasheet Cradle Relay, Accessories and Mounting 2 07-2012, Rev. 0712 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company