Power PCB relay OMIH
- 1pole 10/16A, 1 form A (NO) or 1 form C (CO) contact
- Meet 5000V dielectric voltage between coil and contacts
- Meet 10000V surge voltage between coil and contacts
- Can provide anti-explosion type
(meet IEC-60079-15/GB3836.1-2010/GB3836.8-2014)
Typical applications
Home appliances (refrigerators, washing machines, microwave ovens), office machines, and room air conditioners
Approvals Coil Data
VDE 40005414, UL E58304, CSA LR48471, Coil voltage range 5 to 48VDC
SEMKO 903200, CQC 08001024660, TUV R50139138 Coil insulation system according UL class 105 (A)
Technical data of approved types on request Coil versions, DC coil
Coil Rated coil Operate Release Coil Rated coil
Contact Data code voltage voltage voltage resistance power
(VDC) VDC VDC Ohm +/-10% mW
Contact arrangement 1 Form A (NO), 1 Form C (CO)
Rated voltage 250VAC / 30VDC Standard coil, 720mW
Max. switching voltage 250VAC / 30VDC 05 5 3.5 0.25 36 720
Rated current 16A 06 6 4.2 0.3 48.5 720
Contact material Ag alloy 09 9 6.3 0.45 115 720
Min. recommended contact load 100mA 5VDC 12 12 8.4 0.6 200 720
Initial contact resistance 100m @ 1A, 6VDC 24 24 16.8 1.2 820 720
-1
Frequency of operation, with/without load 48 48 33.6 2.4 3300 720
360 /18000h
Operate/Release time Max. Sensitive coil, 540mW
standard coil: 15ms/8ms 05 5 3.75 0.25 49 540
sensitive coil: 20ms/8ms 06 6 4.5 0.3 68.0 540
Electrical endurance 09 9 6.75 0.45 155 540
Type Load Cycles 12 12 9.0 0.6 270 540
3
IEC 61810 16 A, 250 VAC, resistive 540
10010 at 85 24 24 18.0 1.2 1100
3
16 A, 30VDC 48 48 36.0 2.4 4400 540
3010 room temp
3
UL508 16 A, 250 VAC, resistive 3010 at 85 All figures are given for coil without pre-energization, at ambient temperature +23
3
16 A, 250 VAC general use 10010 room temp
Insulation Data
(anti-explosive type)
Keep the vent hole open during test (except anti-explosive type) Initial dielectric strength
6
Mechanical endurance between open contacts 1000Vms
10X10 ops
between contact and coil 5000Vms
Initial surge withstand voltage
between contact and coil 10000V
Initial insulation resistance 1000M
Clearance/creepage
between contact and coil 5.5mm/8mm
Electrical endurance Coil temperature rise
Copyright 2017 by Tyco Electronics(Shenzhen)Co.,Ltd. All rights reserved. Edition: Jan/2017 Rev. E
Tyco Electronics Shenzhen office
Tower A, World Finance Centre, 4003 East Shennan Road, Luo Hu District, Shenzhen, PRC 518008Power PCB relay OMIH
Other Data Terminal Assignment
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Bottom view on solder pins
refer to the product Compliance Support Center at
WWW.te.com/customersupport/rohssupportcenter
Ambient temperature -40C to +85C
Category of environmental protection
IEC61810 RTII - flux proof
RTIII - wash tight
2
Shock resistance(functional) 98m/s
2
Shock resistance(destructive)
980m/s
Resistance to soldering heat THT PCB layout
IEC 60068-2-20 RTII: 270C/10s Bottom view on solder pins
RTIII: 260C/5s
Terminal type PCB-THT
Weight about 13g
Packaging unit Tray/50, Carton/1000
Tube/20, Carton/1000
Dimensions
Product code structure Typical product code OMIH -SS -1 12 L M 2 ,XXXXX
Type
OMIH Power PCB Relay OMIH
Sealing
SS Flux proof SH Wash tight
Poles
1 1 pole
Coil
Coil code: please refer to coil version table (e.g., 12 = 12VDC)
Coil power
D Standard 720mW L Sensitive 540mW
Contact arrangement
Blank 1 Form C M 1 Form A ,SPST-NO
Contact material
Copyright 2017 by Tyco Electronics(Shenzhen)Co.,Ltd. All rights reserved. Edition: Jan/2017 Rev. E
Tyco Electronics Shenzhen office
Tower A, World Finance Centre, 4003 East Shennan Road, Luo Hu District, Shenzhen, PRC 518008