SPECIFICATION CONTROL DRAWING
10595
70 OHM, AWG 24, 19 STRANDS OF AWG 36, Date:
04-09-04
RADIO FREQUENCY, MULTIPLEX DATA BUS
CHEMINAX H
Revision:
Page 1 of 2
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
Page 2 is for Internal use only.
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
CHARACTERISTIC IMPEDANCE 70 5 ohms, Method C at 1 MHz
DESIGNATED.
CAPACITANCE - MUTUAL 30 pF/ft. (maximum)
CONDUCTORS
ATTENUATION 1.0 dB/100 ft. (nominal) at 1 MHz
AWG 24, 19 Strands of
1.4 dB/100 ft. (maximum) at 1 MHz
.025 AWG 36, Silver-Coated
High Strength Copper
Alloy
.047
.003
DIELECTRICS
Radiation-Crosslinked
ADDITIONAL REQUIREMENTS
Modified ETFE
Colors - Light Blue/White
COMPONENT WIRE PRIOR TO CABLING (Test procedures per MIL-W-22759)
CROSSLINK PROOF 300 3C for 1 hour, .625 inch
mandrel, .375 lb.,
2.5 kV dielectric test
LOW TEMPERATURE -
COLD BEND -65 2C for 4 hours, .500 inch
mandrel, 1.00 lb.,
2.5 kV dielectric test
SHRINKAGE 200 3C for 1 hour, .125 inch
SHIELD
(maximum) in 12 inches
.111
INSULATION RESISTANCE 5000 megohms for 1000 ft. (minimum)
AWG 38,
INSULATION (DIELECTRIC)
Tin-Coated Copper
TENSILE STRENGTH 5000 lbf/in (minimum)
ELONGATION 50% (minimum)
INSULATION FLAWS
SPARK TEST 3000 volts (rms)
IMPULSE TEST 8.0 kV (peak)
FINISHED CABLE (Test procedures per NEMA WC27500)
BLOCKING 200C for 6 hours
LOW TEMPERATURE -
JACKET
COLD BEND -55 5C for 4 hours, 6.00 inch mandrel
.127 Radiation-Crosslinked
CROSSLINKED VERIFICATION 300 5C for 6 hours, 6.00 inch mandrel
Modified ETFE
(nominal)
FLAMMABILITY 3 seconds (maximum); 3.0 inches
.133
(Method B of Spec 1200) (maximum), no flaming of facial tissue
(maximum)
JACKET FLAWS
SPARK TEST 1000 volts (rms)
IMPULSE TEST 6.0 kV (peak)
JACKET
TENSILE STRENGTH 5000 lbf/in (minimum)
ELONGATION 50% (minimum)
SHIELD COVERAGE 90% (minimum)
JACKET THICKNESS .008 inch (nominal)
VOLTAGE WITHSTAND 1500 volts (rms)
(DIELECTRIC)
Outer jacket color will be white (designated by a-9" appended
Replaces EPD5618 and 5671
to the part number, e.g. 10595-9) unless otherwise specified.
The length of lay shall be .75 inch (minimum) to 1.25 inches (maximum)
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and suffixes may be added to
the part number, as necessary, to capture any additional
WEIGHT 13.4 lbs/1000 ft. (maximum)
requirements imposed by the purchase order.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
THIS SPECIFICATION SHEET TAKES PRECEDENCE
501 Oakside Avenue
OVER DOCUMENTS REFERENCED HEREIN.
RRRRR Redwood City, California 94063-3800
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE
1-800-227-8816 Fax: 1-650-361-6297
Wire & Cable
IN EFFECT ON DATE OF INVITATION FOR BID.X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Multi-Conductor Cables category:
Click to view products by TE Connectivity manufacturer:
Other Similar products are found below :
89504-002-1000 89705-008-500 6000FE-877-1000 CS2885-000 M27500-20SP2S23 6309UE-877-1000 M3905-BK005 6502FE 8771000
CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405
CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000 83318E-009-500 8348-060-500 83559-002-
1000 83653-002-5000 8404-060-500 8469 060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100
8747-060-1000 8769-060-1000 8775-060-500 8780-060-1000 8782-001-U1000 9159-060-500 9318-060-1000 939870-000 9423 060U500
9444 060U1000 9497 0001000 9520-060-1000 9524-060-1000 9546-060-500 9572-002-U500 9774-060-1000 A43962-000 1232A1-008-
1000