SCD 82A0111 SPECIFICATION CONTROL DRAWING Date Revision Title WIRE, RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE-INSULATED, 1-21-22 U LIGHTWEIGHT, GENERAL PURPOSE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 80. CONDUCTOR - TIN-COATED COPPER INSULATION - RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE TABLE I. CONSTRUCTION DETAILS FINISHED WIRE DIAMETER OF CONDUCTOR STRANDED WIRE MAXIMUM PART NUMBER STRANDING MAXIMUM CONDUCTOR SIZE RESISTANCE DIAMETER 1/ (number x WEIGHT (inch) (AWG) AT 20C (inch) AWG) (lbs/1000 ft.) (ohms/1000 ft.) MINIMUM MAXIMUM 82A0111-28-* 28 42 x 44 .013 .017 71.4 .029 .003 1.0 82A0111-26-* 26 63 x 44 .017 .021 43.5 .033 .003 1.4 82A0111-24-* 24 105 x 44 .023 .027 28.2 .037 .003 2.1 82A0111-22-* 22 154 x 44 .029 .033 19.2 .043 .003 2.9 82A0111-20-* 20 154 x 42 .037 .043 11.7 .053 .004 4.2 82A0111-18-* 18 259 x 42 .047 .053 7.14 .064 .004 6.7 82A0111-16-* 16 259 x 40 .061 .067 4.53 .079 .004 10.2 82A0111-14-* 14 665 x 42 .078 .086 2.96 .099 .005 16.5 82A0111-12-* 12 665 x 40 .096 .106 1.89 .121 .006 24.8 82A0111-10-* 10 665 x 38 .126 .140 1.12 .157 .009 42.2 82A0111-8-* 8 665 x 36 .157 .173 .714 .195 .010 66.3 82A0111-6-* 6 1045 x 36 .192 .208 .490 .236 .011 102. 82A0111-4-* 4 1665 x 36 .265 .285 .326 .318 .013 169. 82A0111-2-* 2 1665 x 34 .325 .345 .204 .385 .014 252. 82A0111-1-* 1 2109 x 34 .370 .400 .163 .445 .019 317. 82A0111-0-* 0 2660 x 34 .435 .465 .133 .516 .020 407. 82A0111-00-* 00 3325 x 34 .485 .515 .102 .566 .020 502. 82A0111-000-* 000 4123 x 34 .540 .575 .087 .628 .020 619. 82A0111-0000-* 0000 5320 x 34 .615 .655 .066 .711 .020 795. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Raychem Wire & Cable DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Phone: 1-800-227-8816 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2013-2022 TE Connectivity Ltd. family of companies. All rights reserved. Revision SCD SPECIFICATION CONTROL DRAWING U Page 2 of 2 82A0111 TABLE II. PERFORMANCE DETAILS BEND TESTING PART NUMBER MANDREL DIAMETER WEIGHT (inch) ( 3%) (lbs) ( 3%) 1/ CROSSLINKING PROOF TEST CROSSLINKING PROOF TEST 82A0111-28-* .250 .125 82A0111-26-* .375 .125 82A0111-24-* .375 .250 82A0111-22-* .500 .375 82A0111-20-* .500 .500 82A0111-18-* .500 .500 82A0111-16-* .750 .750 82A0111-14-* 1.00 1.00 82A0111-12-* 1.50 1.50 82A0111-10-* 2.00 1.50 82A0111-8-* 3.00 2.00 82A0111-6-* 3.00 2.00 82A0111-4-* 4.00 2.50 82A0111-2-* 6.00 3.00 82A0111-1-* 8.00 4.00 82A0111-0-* 8.00 4.00 82A0111-00-* 8.00 4.00 82A0111-000-* 8.00 4.00 82A0111-0000-* 8.00 4.00 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C INSULATION THICKNESS: Maximum continuous conductor temperature AWG 28-16: 0.004 in. (minimum) VOLTAGE RATING: 600 volts (rms) at sea level AWG 14-10: 0.006 in. (minimum) COLOR: White preferred AWG 8-0000: 0.012 in. (minimum) CONCENTRICITY: 70% (minimum) SECANT MODULUS (Test per ASTM D 882): 4 2 CROSSLINKING PROOF TEST: 300 3C for 7 hours AWG 28-10: 5.0 x 10 lbf/in (maximum) 4 2 IDENTIFICATION AND COLOR STRIPING DURABILITY: AWG 8-0000: 4.0 x 10 lbf/in (maximum) 125 cycles (250 strokes) (minimum), 500 gram weight 2% strain, 2 inch jaw separation, 0.2 inch/minute INSULATION ELONGATION AND TENSILE STRENGTH: SHRINKAGE: 150 3C for 6 hours AWG 28-26: Elongation, 75% (minimum) AWG 28-10: 0.13 in. (maximum) in 12 inches 2 Tensile Strength, 3000 lbf/in (minimum) AWG 8-0000: 0.25 in. (maximum) in 12 inches AWG 24-10: Elongation, 75% (minimum) VOLTAGE WITHSTAND (Post Environmental): 2 Tensile Strength, 3500 lbf/in (minimum) 2500 volts (rms), 60 Hz AWG 8-0000: Elongation, 125% (minimum) 2 Tensile Strength, 3000 lbf/in (minimum) 1/ PART NUMBER: INSULATION FLAWS: The in the part numbers on pages 1 and 2 shall be replaced by a Spark Test, 1.5 kV (rms) at 3 kHz color code designator. Impulse Dielectric Test, 6.0 kV (peak) Example: AWG 12, white 82A0111-12-9 AWG 12, white with a black stripe 82A0111-12-90 1/ See footer section on page 1