SPECIFICATION CONTROL DRAWING 82A6063 TITLE Date Revision THREE CONDUCTOR CABLE, DOUBLE SHIELDED, 1-12-07 A JACKETED, GENERAL PURPOSE, FLEXIBLE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 80. COMPONENT WIRES - 82A0111 SHIELDS - TIN-COATED COPPER JACKET - RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE CABLE CONSTRUCTION DETAILS INNER OUTER OUTSIDE DIAMETER JACKET THICKNESS MAXIMUM CONDUCTOR SHIELD SHIELD (inch) (inch) PART NUMBER WEIGHT SIZE SIZE SIZE 1/ (lb/1000 ft) (AWG) (AWG) (AWG) MINIMUM NOMINAL NOMINAL MAXIMUM 82A6063-22-* 22 38 38 .007 .010 .147 .154 23.7 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C SHIELD ANGLE: 26 minimum, 30 maximum (each) Maximum continuous conductor temperature SHIELD COVERAGE: 85% (minimum) (each) VOLTAGE RATING: 600 volts (rms) at sea level VOLTAGE WITHSTAND (Post Environmental): CROSSLINKING PROOF TEST: 300 3C for 7 hour, 1000 volts (rms), 60 Hz, 1 minute DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz JACKET COLOR: White preferred JACKET ELONGATION AND TENSILE STRENGTH: PART NUMBER Elongation, 100% (minimum) The in the part number above shall be replaced 2 Tensile Strength, 3000 lbf/in (minimum) by color code designators with a slash separating JACKET FLAWS: the component wire colors and a dash separating Spark Test, 1500 volts (rms) the component wire colors from the jacket color. Impulse Dielectric Test, 6.0 kV (peak) Colors shown do not necessarily reflect the sequence SECANT MODULUS (Test per ASTM D 882): of manufacturing. 4 2 1/ Example: AWG 20, black, brown and red 4.0 x 10 lbf/in (maximum), 2% strain, 2 inch jaw separation, 0.2 inch/minute component wires white jacket: 82A6063-20-0/1/2-9 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. R Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 2 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. page 2 is for internal use only 2007 Tyco Electronics Corporation. All rights reserved.Revision SCD Number SPECIFICATION CONTROL DRAWING Page 2 of 2 A 82A6063 FOR EMBRAER INFORMATION ONLY Minimum Bend Radius (for non-flexing applications only): 5x the finished cable diameter Note: If wrinkling occurs on inside of bend, cable should be replaced.