.125 3.18 x .125 3.18 Centerline AMPMODU Interconnection System Level V IDC Connectors, .125 x .125 3.18 x 3.18 Centerline Product Facts Termination of discrete wire sizes 26-22 AWG 2 0.12-0.3 mm as well as jacketed cable and bonded ribbon cable (conductors separated) Connectors stackable end- to-end and side-to-side on .125 3.18 centers Connectors preloaded with insulation displacement receptacle contacts Contact design employs dual cantilever beams, redundant insulation displacement slots, built-in post stop and wire support crimp Copper alloy contacts are duplex plated Snap-on covers with or without cable tie paddles Full line of mass termination tooling offers lowest installed costs for AMPMODU Level V IDC Covers can be furnished Performance most production needs connectors provide cost with and without a cable tie Characteristics Recognized under the effective discrete wire paddle. The covers are Contact Current Rating Component Program of connections that are simply snapped onto a 3 amperes Underwriters compatible with today s housing after the connector Termination Resistance Laboratories Inc., telecommunications has been terminated. R 12 milliohms (max.) File No. E28476 packaging techniques. The receptacle contacts Durability Ref. Product These connectors are Certified by Canadian feature the Tyco Electronics Specification 108-25028 designed to mate with .025 Standards insulation displacement (Interconnection System, Insulation R 0.64 sq. posts on .125 x Displacement Connector, IDC Level) Association, crimp technique for .125 3.18 x 3.18 centers File No. LR 7189 achieving top quality, low and are comprised of cost terminations. These Application Specification double-row housings contacts employ dual 114-25020 (Interconnection System, preloaded with insulation IDC Level V, Application of) cantilever beams for displacement receptacle redundant interface with a contacts, snap-on mating post, an integral 6 hermaphroditic covers, and post stop to limit post a full line of mass termination mating depth and protect tooling to meet virtually the crimp termination, and every production need. For a wire support (strain relief) modular flexibility, connectors crimp to prevent accidental can be stacked end-to-end wire pull-out. The contacts or side-to-side, maintaining are made of high a .125 x .125 3.18 x 3.18 conductivity copper alloy centerline spacing. and are duplex plated. 279 Catalog 1307819 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000 Revised 8-08 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: 44-8706-080-208aAMPMODU Interconnection System Receptacle Assemblies, Double-Row, .125 x .125 3.18 x 3.18 Centerline Housings Preloaded with Insulation Displacement Crimp Receptacle Contacts .800 20.32 Material and Finish .298 7.57 Housing Black thermoplastic, flame retardant Contacts Copper alloy, duplex plated .000050 0.00127 gold on A contact area, .000100 0.00254 min. tin in crimp area, with entire contact underplated .000050 0.00127 nickel Note: Preloaded contacts accept max059 B insulation dia. of .050 1.27 . The mini- 1.50 mum point of contact, as measured from front edge of housing, is .095 2.41 243 6.17 Technical Documents .125 .125 pages 277, 278 3.18 Typ. 3.18 Product Specification 108-25028 Application Specification 114-25020 Receptacle assemblies can be stacked end-to-end and side-to- side on .125 x .125 3.18 x 3.18 centers. 1 Receptacle Assembly (Stamped ) Dimensions No. of for 26-22 AWG Pos. AB 2 0.12-0.3 mm Wire 8 .493 12.52 .375 9.52 102935-4 10 .618 15.70 .500 12.70 102935-6 12 .743 18.87 .625 15.88 102935-8 6 16 .993 25.22 .875 22.23 1-102935-2 20 1.243 31.57 1.125 28.58 1-102935-6 24 1.493 37.92 1.375 34.93 1-102935-9 30 1.868 47.45 1.750 44.45 1-102935-3 32 1.993 50.62 1.875 47.63 2-102935-8 40 2.493 63.32 2.375 60.33 3-102935-6 1 White ink stamped, one side8- thru 12-position with AMP and arrow 14- and 16-position with AMP, part no., and arrow 18- thru 40-position with AMP, part no., date code and arrow. Notes: 1. Covers for these housings are shown on pages 281 & 282. 2. Termination tooling for these connectors are shown on page 273-275. 3. 14- and 18-position receptacle assemblies, as well as other sizes, can be made available upon request. Consult Tyco Electronics. Note: All part numbers are RoHS compliant. 280 Catalog 1307819 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000 Revised 8-08 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: 44-8706-080-208a .125 3.18 x .125 3.18 Centerline