SCD 55/0312 SPECIFICATION CONTROL DRAWING Date Revision Title WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, 6-6-17 K ULTRA LIGHTWEIGHT, OUTER SPACE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 55/. CONDUCTOR - SILVER-COATED COPPER INSULATION - RADIATION-CROSSLINKED, MODIFIED ETFE TABLE I. CONSTRUCTION DETAILS DIAMETER OF FINISHED WIRE STRANDED WIRE CONDUCTOR MAXIMUM PART NUMBER MAXIMUM CONDUCTOR SIZE STRANDING RESISTANCE DIAMETER 1/ WEIGHT (inch) (AWG) (number x AWG) AT 20C (inch) (lbs/1000 ft.) MINIMUM MAXIMUM (ohms/1000 ft.) 55/0312-30-* 30 7 x 38 .0110 .0120 100.7 .0195 .0015 .52 55/0312-28-* 28 7 x 36 .0140 .0150 63.8 .0225 .0015 .76 55/0312-26-* 26 19 x 38 .0175 .0191 38.4 .0274 .0017 1.22 55/0312-24-* 24 19 x 36 .0225 .0241 24.3 .0322 .0017 1.79 55/0312-22-* 22 19 x 34 .0285 .0301 15.1 .0390 .0017 2.70 55/0312-20-* 20 19 x 32 .0365 .0385 9.19 .0495 .0017 4.27 55/0312-18-* 18 19 x 30 .0452 .0476 5.79 .0590 .0017 6.56 55/0312-16-* 16 19 x 29 .0514 .0538 4.52 .0665 .0019 8.33 55/0312-14-* 14 19 x 27 .0644 .0674 2.88 .0810 .0021 12.81 55/0312-12-* 12 37 x 28 .0825 .0865 1.90 .1000 .0026 19.71 55/0312-10-* 10 37 x 26 .1050 .1090 1.19 .1260 .0040 31.70 TABLE II. PERFORMANCE DETAILS CROSSLINKED VERIFICATION - BEND TESTING PART NUMBER MANDREL DIAMETER WEIGHT 1/ (inch) ( 3%) (lb) ( 3%) 55/0312-30-* .250 .063 55/0312-28-* .250 .063 55/0312-26-* .375 .063 55/0312-24-* .375 .125 55/0312-22-* .500 .188 55/0312-20-* .500 .250 55/0312-18-* .500 .250 55/0312-16-* .750 .375 55/0312-14-* 1.00 .500 55/0312-12-* 1.50 .750 55/0312-10-* 2.00 .750 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, and TE Connectivity (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. Redwood City, CA 94063-3800 Page 1 of 2 Phone: 1-800-522-6752 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2006-2017 TE Connectivity Ltd. family of companies. All Rights Reserved. Page Revision SCD SPECIFICATION CONTROL DRAWING 55/0312 2 of 2 K WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level COLOR: White preferred CONCENTRICITY: 80% (minimum) CROSSLINKED VERIFICATION: 300 3C for 1 hour IDENTIFICATION AND COLOR STRIPING DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight INSULATION ELONGATION: 50% (minimum) INSULATION FLAWS: Spark Test, 1.5 kV (rms) (30-24 AWG) 3.0 kV (rms) (22-10 AWG) Impulse Dielectric Test, 6.0 kV (peak) INSULATION THICKNESS: .004 in. (nominal) RADIATION RESISTANCE: 500 megarads SHRINKAGE: 230 3C for 1 hour, 0.125 in. (maximum) in 12 inches VACUUM STABILITY: Total Mass Loss (TML), 1.00% (maximum) Volatile Condensable Material (VCM): 0.10% (maximum) VOLTAGE WITHSTAND (Post Environmental): 1500 volts (rms), 60 Hz, 5 minutes 1/ PART NUMBER: The in the part numbers in Tables I and II shall be replaced by a color code designator. Example: AWG 20, white: 55/0312-20-9 AWG 20, white with a black stripe: 55/0312-20-90 1/ See footer section on page 1