SCD 400R0111 SPECIFICATION CONTROL DRAWING Date Revision Title WIRE, RADIATION-CROSSLINKED, POLYOLEFIN-INSULATED, LIMITED FIRE HAZARD, 600 VOLT 3-8-16 B This specification sheet forms a part of the latest issue of Raychem Specification WCD 3114. PRIMARY INSULATION - RADIATION-CROSSLINKED, POLYOLEFIN CONDUCTOR - TIN-COATED COPPER JACKET - RADIATION-CROSSLINKED, FLUOROPOLYMER Thickness: .003 .001 in. (.051 mm min, .102 mm max) TABLE I. CONSTRUCTION DETAILS FINISHED WIRE DIAMETER OF MAXIMUM WIRE CONDUCTOR MAXIMUM STRANDED CONDUCTOR PART NUMBER DIAMETER RESISTANCE SIZE STRANDING (inch) (mm) WEIGHT 1/ (inch) (mm) AT 20C (AWG) (number x AWG) (lbs/1000 ft.) (ohms/1000 ft.) (kg/km) (ohms/km) MINIMUM MAXIMUM MINIMUM MAXIMUM 400R0111-26-* 26 19 x 38 .018 (.457) .021 (.533) 41.3 (135.) .032 (.813) .036 (.914) 1.4 (2.08) 400R0111-24-* 24 19 x 36 .023 (.584) .026 (.660) 26.2 (86.0) .038 (.965) .042 (1.07) 2.0 (2.98) 400R0111-22-* 22 19 x 34 .029 (.737) .033 (.838) 16.2 (53.1) .045 (1.14) .049 (1.24) 3.0 (4.46) 400R0111-20-* 20 19 x 32 .037 (.940) .041 (1.04) 9.88 (32.4) .053 (1.35) .057 (1.45) 4.5 (6.70) 400R0111-18-* 18 19 x 30 .046 (1.17) .051 (1.30) 6.23 (20.4) .063 (1.60) .067 (1.70) 6.8 (10.1) 400R0111-16-* 16 19 x 29 .052 (1.32) .058 (1.47) 4.81 (15.8) .069 (1.75) .075 (1.91) 8.6 (12.8) 400R0111-14-* 14 19 x 27 .065 (1.65) .073 (1.85) 3.06 (10.0) .085 (2.16) .093 (2.36) 13.2 (19.6) 400R0111-12-* 12 37 x 28 .084 (2.13) .090 (2.29) 2.02 (6.63) .104 (2.64) .112 (2.84) 20.2 (30.1) 400R0111-10-* 10 37 x 26 .106 (2.69) .114 (2.90) 1.26 (4.13) .125 (3.18) .133 (3.38) 31.1 (46.3) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. Redwood City, CA 94063-3800 Page 1 of 2 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2015-2016 Tyco Electronics Corporation. All rights reserved. Page Revision SCD SPECIFICATION CONTROL DRAWING 2 of 2 B 400R0111 TABLE II. PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER WEIGHT PART NUMBER (inch) (mm) ( 3%) (lb) (kg) ( 3%) 1/ ACCELERATED COLD ACCELERATED COLD AGING BEND AGING BEND 400R0111-26-* .500 (12.7) .500 (12.7) .250 (.113) .500 (.227) 400R0111-24-* .500 (12.7) .500 (12.7) .375 (.170) .500 (.227) 400R0111-22-* .750 (19.1) .750 (19.1) .375 (.170) 1.00 (.454) 400R0111-20-* .750 (19.1) .750 (19.1) .375 (.170) 1.00 (.454) 400R0111-18-* 1.00 (25.4) 1.00 (25.4) .500 (.227) 1.00 (.454) 400R0111-16-* 1.00 (25.4) 1.00 (25.4) .500 (.227) 1.00 (.454) 400R0111-14-* 1.50 (38.1) 1.50 (38.1) 1.00 (.454) 3.00 (1.36) 400R0111-12-* 2.00 (50.8) 2.00 (50.8) 1.00 (.454) 3.00 (1.36) 400R0111-10-* 2.50 (63.5) 2.50 (63.5) 1.00 (.454) 3.00 (1.36) WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 125C INSULATION RESISTANCE: Maximum continuous conductor temperature 5000 megohms for 1000 ft. (1524 megohms for 1 km) (minimum) VOLTAGE RATING: 600 volts (rms) at sea level LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours ACCELERATED AGING: 300 2C for 6 hours SHRINKAGE: 300 2C, 0.125 in. (3.18 mm) (maximum) in 12 inches (305 mm) Identification legibility, 225 2C for 6 hours SMOKE RELEASE: 2 BLOCKING: 150 2C for 24 hours Peak Smoke Release Rate, 0.40 m /s (maximum) 2 COLOR: White preferred Total Smoke Release, 150 m (maximum) FLAMMABILITY: Char Length, 5 ft. (1.5 m) (maximum) SMOKE TEST: D4, 50 (maximum) Dm, 300 (maximum) HUMIDITY RESISTANCE: Insulation Resistance, TOXICITY: HCN: 100 ppm (maximum) SO2: 100 ppm (maximum) 5000 megohms for 1000 ft. (1524 megohms for 1 km) (minimum) CO: 3500 ppm (maximum) HF: 100 ppm (maximum) INSULATION ELONGATION AND TENSILE STRENGTH: NO: 100 ppm (maximum) HCI: 500 ppm (maximum) Primary Insulation, VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes Elongation, 150% (minimum) 2 Tensile Strength, 2500 lbf/in (17.2 MPa) (minimum) 1/ PART NUMBER: INSULATION FLAWS: The in the part numbers in Tables I and II shall be replaced by a color code Primary Insulation, designator. Spark Test, 1.5 kV (rms) Example: AWG 20, white: 400R0111-20-9 Impulse Dielectric Test, 6.0 kV (peak) AWG 20, white with a black stripe: 400R0111-20-90 Finished Wire, Spark Test, 3.0 kV (rms) at 3 kHz PRODUCT IDENTIFICATION: Impulse Dielectric Test, 8.0 kV (peak) Outer surface of wire shall be marked in contrasting color as follows: RAYCHEM 400R0111-xx - 600V Yr of Mf (xx = applicable AWG size) 1/ See footer section on page 1