SPECIFICATION CONTROL DRAWING 5022N5522 Date: 12-13-05 50 OHM, AWG 22, 19 STRANDS OF 34 AWG, COAXIAL CABLE CHEMINAX E Revision: Page 1 of 2 THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. Page 2 is for Internal use only. CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. CHARACTERISTIC IMPEDANCE 50 2 ohms, Method A CAPACITANCE 26.0 pF/ft. (nominal) .0315 VELOCITY OF PROPAGATION 78% (nominal) CONDUCTOR AWG 22, 19 strands of ATTENUATION 2.0 dB/100 ft (nominal) at 10 MHz AWG 34, Silver-Coated Copper .084 DIELECTRIC Rayfoam H Color - White ADDITIONAL REQUIREMENTS .092 WRAP Aluminum Polyester ELECTRICAL Aluminum side facing out CONDUCTOR RESISTANCE 14.4 ohms/1000 ft. (nominal) INSULATION RESISTANCE 10,000 megohms (minimum) (CONDUCTOR TO SHIELD) for 1000 ft109 1st SHIELD JACKET FLAWS AWG 38 Round Tin-Coated Copper SPARK TEST 1.0 kV (rms) IMPULSE TEST 6.0 kV (peak) VOLTAGE WITHSTAND .125 1st JACKET (DIELECTRIC) ETFE CONDUCTOR TO SHIELD 1000 volts (rms) (minimum) Color - White SHIELD TO SHIELD 500 volts (rms) (minimum) ENVIRONMENTAL .142 2nd SHIELD FLAMMABILITY Method B AWG 38 Round LOW TEMPERATURE- -55C/4.25 inch mandrel Tin-Coated Copper COLD BEND VOLTAGE WITHSTAND (POST ENVIRONMENTAL) 1000 volts (rms), 1 minute PHYSICAL 2nd JACKET .158 INSULATION (DIELECTRIC) ETFE ELONGATION 50% (minimum) 2 TENSILE STRENGTH 600 lbf/in (minimum) JACKET (EACH) ELONGATION 150% (minimum) 2 TENSILE STRENGTH 5000 lbf/in (minimum) JACKET THICKNESS (EACH) .008 inch (nominal) SHIELD COVERAGE (EACH) 90% (minimum) Outer jacket color will be white (designated by a-9 appended to the part number, e.g. 5022N5522-9) unless otherwise specified. Designate outer jacket color with a dash number in accordance with MIL-STD-681. Other codes and suffixes may be added to WEIGHT 23.1 lbs/1000 ft. (nominal) the part number, as necessary, to capture any additional requirements imposed by the purchase order. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. 501 Oakside Avenue R Redwood City, California 94063-3800 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 1-800-227-8816 Fax: 1-650-361-6297 Wire & Cable 2005 Tyco Electronics Corporation. All rights reserved. ReviewRevision SCD Number Page 2 of 2 SPECIFICATION CONTROL DRAWING E 5022N5522 FOR EMBRAER INFORMATION ONLY Minimum Bend Radius (for non-flexing applications only): 5x the finished cable diameter Note: If wrinkling occurs on inside of bend, cable should be replaced.