SCD
FLDW+0311
SPECIFICATION CONTROL DRAWING
Date Revision
Title
DUAL WALL HOOKUP WIRE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED, 600 VOLT
8-6-19 R
The complete requirements for procuring the wire described herein shall consist of this document and the issue in effect of
Raychem Specification WCD 3106, UL Subject 758, Style 3584, File E303150 and carries UL labels to this effect.
PRIMARY INSULATION - RADIATION-CROSSLINKED,
EXTRUDED POLYALKENE
CONDUCTOR - TIN-COATED COPPER JACKET - RADIATION-CROSSLINKED,
MODIFIED PVDF
TABLE I. CONSTRUCTION DETAILS
FINISHED WIRE
NOMINAL
MAXIMUM
WIRE CONDUCTOR
MAXIMUM
DIAMETER
PART NUMBER CONDUCTOR
RESISTANCE
SIZE STRANDING
WEIGHT
(inch) (mm)
1/ DIAMETER
AT 20C
(AWG) (number x AWG)
(lbs/1000 ft.)
(inch) (mm)
(ohms/1000 ft.)
(kg/km)
(ohms/km)
MINIMUM NOMINAL MAXIMUM
FLDWC0311-26-* 26 19 x 38 .019 (.483) 45.8 (150.) .038 (.965) .040 (1.02) .042 (1.07) 1.6 (2.38)
FLDWC0311-24-* 24 19 x 36 .024 (.610) 28.7 (94.2) .044 (1.12) .046 (1.17) .048 (1.22) 2.4 (3.57)
FLDWC0311-22-* 22 19 x 34 .030 (.762) 18.1 (59.4) .052 (1.32) .054 (1.37) .056 (1.42) 3.5 (5.21)
FLDWC0311-20-* 20 19 x 32 .038 (.965) 11.4 (37.4) .060 (1.52) .062 (1.57) .064 (1.63) 5.1 (7.59)
FLDWC0311-18-* 18 19 x 30 .047 (1.19) 7.15 (23.5) .070 (1.78) .073 (1.85) .076 (1.93) 7.7 (11.5)
FLDWC0311-16-* 16 19 x 29 .053 (1.35) 4.82 (15.8) .078 (1.98) .081 (2.06) .084 (2.13) 9.8 (14.6)
FLDWC0311-14-* 14 19 x 27 .066 (1.68) 3.05 (10.0) .094 (2.39) .098 (2.49) .102 (2.59) 14.7 (21.9)
FLDWC0311-12-* 12 19 x 25 .090 (2.29) 1.92 (6.30) .118 (3.00) .122 (3.10) .126 (3.20) 24.5 (36.5)
FLDWD0311-12-* 12 37 x 28 .085 (2.16) 2.01 (6.59) .113 (2.87) .117 (2.97) .121 (3.07) 22.1 (32.9)
FLDWD0311-10-* 10 37 x 26 .107 (2.72) 1.26 (4.13) .142 (3.61) .146 (3.71) .150 (3.81) 35.6 (53.0)
FLDWE0311-8-* 8 133 x 29 .160 (4.06) .701 (2.30) .200 (5.08) .206 (5.23) .212 (5.38) 61.8 (92.0)
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
TE Connectivity also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE connectivity, and TE connectivity (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
Redwood City, CA 94063-3800
Page 1 of 2
Phone: 1-800-522-6752
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
Fax: 1-650-361-6297
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
2005-2019 TE Connectivity Ltd. family of companies. All Rights Reserved.
Page Revision SCD
SPECIFICATION CONTROL DRAWING
FLDW+0311
2 of 2 R
TABLE II. PERFORMANCE DETAILS
CROSSLINK VERIFICATION - BEND TESTING
PART NUMBER
MANDREL DIAMETER WEIGHT
1/
(inch) (mm) ( 3%) (lb) (kg) ( 3%)
FLDWC0311-26-* .500 (12.7) .375 (.170)
FLDWC0311-24-* .500 (12.7) .375 (.170)
FLDWC0311-22-* .750 (19.1) .375 (.170)
FLDWC0311-20-* .750 (19.1) .500 (.227)
FLDWC0311-18-* 1.00 (25.4) .500 (.227)
FLDWC0311-16-* 1.00 (25.4) 1.00 (.454)
FLDWC0311-14-* 1.50 (38.1) 1.00 (.454)
FLDWC0311-12-* 2.00 (50.8) 1.50 (.680)
FLDWD0311-12-* 2.00 (50.8) 1.50 (.680)
FLDWD0311-10-* 3.00 (76.2) 2.00 (.907)
FLDWE0311-8-* 3.00 (76.2) 3.00 (1.36)
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 125C THERMAL STABILITY: 158C for 168 hours
VOLTAGE RATING: 600 volts (rms) at sea level Elongation Retention, 70% (minimum)
CROSSLINK VERIFICATION: 300 3C for 1 hour Tensile Strength Retention, 70% (minimum)
FLAME RATING: VW-1 VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes
INSULATION ELONGATION AND TENSILE STRENGTH:
Primary Insulation, 1/ PART NUMBER:
Elongation, 150% (minimum) The in the part number in the upper right hand corner of pages 1 and 2 shall
2
Tensile Strength, 2500 lbf/in (17.2 MPa) (minimum) be replaced with a letter designator to define conductor stranding (see part
INSULATION FLAWS: numbers in Tables I and II).
Finished Wire, C = 19 Strands D = 37 Strands E = Rope Lay
Spark Test, 6.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak) The in the part numbers in Tables I and II shall be replaced by a color code
INSULATION THICKNESS: designator.
Primary Insulation, Example: AWG 18, 19 strands, white: FLDWC0311-18-9
.004 inch (.102 mm) (minimum), .005 inch (.127 mm) (minimum average) AWG 18, 19 strands, white with a black stripe: FLDWC0311-18-90
Jacket, .002 inch (.051 mm) (minimum) for AWGs 12 and smaller
Jacket, .004 inch (.102 mm) (minimum) for AWGs 10 and larger
SHRINKAGE: 125C for 1 hour, 0.125 in. ( 3.18 mm) (maximum) per end All spool/reel labels shall include the following: Reinforced Insulatio
1/ See footer section on page 1