FLHT+0311 SPECIFICATION CONTROL DRAWING TITLE Date Revision HIGH TEMPERATURE HOOKUP WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, 600 VOLT 7-21-14 Z The complete requirements for procuring the wire described herein shall consist of this document and the issue in effect of Raychem Specification WCD 3106, UL Subject 758, Style 3557, File E303150 and carries UL labels to this effect. CONDUCTOR - TIN-COATED COPPER INSULATION - RADIATION-CROSSLINKED, MODIFIED ETFE TABLE I. CONSTRUCTION DETAILS FINISHED WIRE CONDUCTOR STRANDING NOMINAL DIAMETER MAXIMUM WIRE NOMINAL PART NUMBER (number x AWG) CONDUCTOR (inch) (mm) RESISTANCE SIZE WEIGHT 1/ or DIAMETER AT 20C (AWG) (lbs/1000 ft.) (number x SEOD) (inch) (mm) (ohms/1000 ft.) MINIMUM NOMINAL MAXIMUM (kg/km) (inch) (mm) (ohms/km) FLHTB0311-18-* 18 7 x 26 .047 (1.19) 7.06 (23.2) .0584 (1.48) .0601 (1.53) .0618 (1.57) 5.95 (8.85) FLHTB0311-16-* 16 7 x 24 .060 (1.52) 4.45 (14.6) .0731 (1.86) .0750 (1.91) .0769 (1.95) 9.75 (14.5) FLHTB0311-14-* 14 7 x .0242 (.615) .073 (1.85) 2.90 (9.51) .0865 (2.20) .0886 (2.25) .0907 (2.30) 14.6 (21.7) FLHTC0311-26-* 26 19 x 38 .019 (.483) 45.8 (150.) .0301 (.765) .0315 (.800) .0329 (.836) 1.27 (1.89) FLHTC0311-24-* 24 19 x 36 .024 (.610) 28.7 (94.2) .0351 (.892) .0365 (.927) .0379 (.963) 1.85 (2.75) FLHTC0311-22-* 22 19 x 34 .030 (.762) 18.1 (59.4) .0411 (1.04) .0425 (1.08) .0439 (1.12) 2.74 (4.08) FLHTC0311-20-* 20 19 x 32 .038 (.965) 11.4 (37.4) .0491 (1.25) .0505 (1.28) .0519 (1.32) 4.17 (6.21) FLHTC0311-18-* 18 19 x 30 .047 (1.19) 7.15 (23.5) .0583 (1.48) .0600 (1.52) .0617 (1.57) 6.34 (9.43) FLHTC0311-16-* 16 19 x 29 .053 (1.35) 4.82 (15.8) .0656 (1.67) .0675 (1.71) .0694 (1.76) 8.09 (12.0) FLHTC0311-14-* 14 19 x 27 .066 (1.68) 3.05 (10.0) .0799 (2.03) .0820 (2.08) .0841 (2.14) 12.5 (18.6) FLHTC0311-12-* 12 19 x 25 .090 (2.29) 1.92 (6.30) .1035 (2.63) .1060 (2.69) .1085 (2.76) 22.4 (33.3) FLHTD0311-14-* 14 37 x 30 .068 (1.73) 3.22 (10.6) .0819 (2.08) .0840 (2.13) .0861 (2.19) 14.5 (21.6) FLHTD0311-12-* 12 37 x 28 .085 (2.16) 2.01 (6.59) .0984 (2.50) .1010 (2.57) .1036 (2.63) 19.3 (28.7) FLHTD0311-10-* 10 37 x 26 .107 (2.72) 1.26 (4.13) .121 (3.07) .125 (3.18) .129 (3.28) 30.7 (45.7) FLHTE0311-8-* 8 133 x 29 .160 (4.06) .701 (2.30) .175 (4.45) .180 (4.57) .185 (4.70) 54.9 (81.7) Due to UL limitations on the usage of small strand bare and tin plated conductors, products with conductor strand diameters less than .015 inch (.381 mm) are intended for dry locations only. For wet locations, other UL recognized products are available. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. Page 1 of 2 Redwood City, CA 94063-3800 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2005-2014 Tyco Electronics Corporation. All rights reserved.Page Revision SCD 2 of 2 Z FLHT+0311 SPECIFICATION CONTROL DRAWING TABLE II. PERFORMANCE DETAILS BEND TESTING PART NUMBER MANDREL DIAMETER WEIGHT 1/ (inch) (mm) ( 3%) (lb) (kg) ( 3%) CROSSLINK VERIFICATION CROSSLINK VERIFICATION FLHTB0311-18-* .500 (12.7) 1.00 (.454) FLHTB0311-16-* .750 (19.1) 1.50 (.680) FLHTB0311-14-* 1.00 (25.4) 2.00 (.907) FLHTC0311-26-* .375 (9.53) .125 (.057) FLHTC0311-24-* .375 (9.53) .500 (.227) FLHTC0311-22-* .500 (12.7) .750 (.340) FLHTC0311-20-* .500 (12.7) 1.00 (.454) FLHTC0311-18-* .500 (12.7) 1.00 (.454) FLHTC0311-16-* .750 (19.1) 1.50 (.680) FLHTC0311-14-* 1.00 (25.4) 2.00 (.907) FLHTC0311-12-* 1.50 (38.1) 3.00 (1.36) FLHTD0311-14-* 1.00 (25.4) 2.00 (.907) FLHTD0311-12-* 1.50 (38.1) 3.00 (1.36) FLHTD0311-10-* 2.00 (50.8) 3.00 (1.36) FLHTE0311-8-* 3.00 (76.2) 4.00 (1.81) WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C SHRINKAGE: 200C for 1 hour, 0.125 inch (3.18 mm) (maximum) per end VOLTAGE RATING: 600 volts (rms) at sea level THERMAL STABILITY: 232C for 168 hours, CROSSLINK VERIFICATION: 300 3C for 1 hour Elongation, 60% (minimum) 2 FLAME RATING: VW-1 Tensile Strength, 5000 lbf/in (minimum) INSULATION ELONGATION AND TENSILE STRENGTH: VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes Elongation, 100% (minimum) 2 Tensile Strength, 5470 lbf/in (minimum) SPOOL LABEL: All spool/reel labels containing conductor strand diameters less than INSULATION FLAWS: .015 inch (.381 mm) shall include For Dry Locations Only Spark Test, 6.0 kV (rms) Impulse Dielectric Test, 8.0 kV (peak) 1/ PART NUMBER: INSULATION THICKNESS: The + in the part number in the upper right hand corner of pages 1 and 2 shall be replaced AWG 26-16: .0055 inch (.140 mm) (minimum), .006 inch (.152 mm) (minimum average) with a letter designator to define conductor stranding (see part numbers in table). AWG 14: .006 inch (.152 mm) (minimum), .0065 inch (.165 mm) (minimum average) B = 7 Strands C = 19 Strands D = 37 Strands E = Rope Lay AWG 12: .0065 inch (.165 mm) (minimum), .007 inch (.178 mm) (minimum average) AWG 10: .007 inch (.178 mm) (minimum), .0075 inch (.191 mm) (minimum average) The * in the part numbers in Tables I and II shall be replaced by a color code designator. AWG 8: .0075 inch (.191 mm) (minimum), .008 inch (.203 mm) (minimum average) Example: AWG 18, 19 strands, white: FLHTC0311-18-9 AWG 18, 19 strands, white with a black stripe: FLHTC0311-18-90 1/ See footer section on page 1