Potter & Brumfield Solid State Relay IAC Series AC Input Module File E29244 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Engineering Data Features Switch Form: 1 Form A (SPST-NO) Industry standard package and pin-out. Duty: Continuous. Color coded by function. Operating Temperature: 30C to +80C. 4000V rms optical isolation. Storage Temperature: 30C to 100C. High immunity to false operation. Potting Compound Flammability: UL94V-0. Series compatible. Approximate Weight: 1.38 oz. (35g). Compatible with 2IO series mounting boards. Ordering Information Typical Part Number > IAC -5 A 1. Basic Series: IAC = AC input module - yellow case 2. Logic Voltage: 5 = 5VDC 15 = 15VDC 24 = 24VDC 3. Input: Blank = 120VAC input (90-140VAC) * * A = 240VAC input (180-280VAC) * * E = 18-36VAC input * * * * Is not polarity sensitive. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. IAC-5 IAC-5A IAC-5E IAC-15 IAC-24 Input Specifications IAC-5 IAC-5A IAC-5E Parameter Conditions Units IAC-15 IAC-24 IAC-15A IAC-24A IAC-15E IAC-24E Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Control Voltage Range VIN VAC 90 120 140 180 240 280 18 24 36 Must Operate Voltage VIN(OP) VAC 90 180 18 Must Release Voltage VIN(REL) VAC 60 60 10 Max. Input Current VIN=Max. mA 1 - 5 1 - 8 0.2 - 2.0 Input Resistance Ohms Current Regulator 1 02-2019, Rev. 0219 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2015 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company Potter & Brumfield Solid State Relay IAC Series(Continued) AC Input Module Output Specifications ( +25C unless otherwise specified) IAC-5 IAC-15 IAC-24 Parameter Conditions Units IAC-5A IAC-5E IAC-15A IAC-15E IAC-24A IAC-24E Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Maximum Output Voltage VDC 30 30 30 Maximum Output Current mADC 50 50 50 Maximum Output Leakage Current VOUT=Max. mA 10 10 10 Maximum Output Voltage Drop ISINK=50mA VDC 0.2 0.2 0.2 Logic Supply Voltage VCC VDC 3 5 6 12 15 18 20 24 30 Logic Supply Current VCC=Max. mADC 15 15 15 Turn-On Time (Nominal) ISINK=25mA ms 20 20 20 Turn-Off Time (Nominal) ISINK=25mA ms 30 30 30 Output Type (Open Collector) Normally Open(SINKING) Normally Open(SINKING) Normally Open(SINKING) IAC Operating Diagram PCB Layout Outline Dimensions Note : Extra nut and washer will be provided on the screw, which will goes under PCB to fix the relay. Hex Nut S= 6.35 (width across flats), Thickness = 2.40 Washer = OD : 4.850.25, ID: 2.750.15, Thickness = 0.55 2 02-2019, Rev. 0219 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2015 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company