FittingsAdjustable Spring Loaded
Quick Release, Dual Threads
Quick Release, Single Thread
Fluid Sealed
FittingsAdjustable Spring Loaded use FEATURES
spring loading pressure to hold probe sensors in
Fluid Sealed
place against the bearing surface for temperature
Spring Loaded
monitoring. These fittings feature quick release
knobs for easy adjustments and fast installation
APPLICATIONS
in a variety of motors and generators. In addition,
Motors
they can also be used in other applications that
Generators
require fluid or pressure sealing.
Process
HVAC
dimensions
Quick Release, Dual Threads, Standard Quick Release, Single Thread
Process Thread Control Thread 1/8" NPT
Quick Release Knob
Quick Release Knob
D
D
(2.50") (1.00")
(2.50") (1.00")
Quick Release, Dual Threads (For Use With Transmitters)
Process Thread Control Thread
Quick Release Knob
D
(2.50") (.25")
D = Inside Diameter
FittingsAdjustable Spring Loaded / Rev 1.1 www.meas-spec.com 01/06/2015
1711 139th Lane NW Andover, MN 55304 +1 800.899.9783 temp.eng.us@meas-spec.comFittingsAdjustable Spring Loaded
performance specifications
Fitting Construction:
Installation Instructions
Stainless Steel for corrosion resistance
Quick Release Knob
Fluid Sealing:
Standard with Viton O-rings for fluid or pressure sealing
Pressure Rating:
Fluid seals havea maximum pressure rating of 50 psi Step 1:
Pull release knob and rotate half turn clockwise to lock open
Quick Release Knob
In Open Position
Step 2:
Slide sensor into fitting to desired immersion length
Quick Release Knob Closed
and Spring Loaded
Step 3:
Pull release knob, rotate half turn counter-clockwise and release
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does
not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without
further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose,
nor does Measureme nt Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liabili ty, including
without limitation consequential or inciden tal damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer
application by customers technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
ordering info
FittingAdjustable Spring Loaded
Model Style
695A Quick Release, Dual Threads, Standard (For Use with Connection Heads)
695F Quick Release, Single Thread, 1/8 NPT Only
695G Quick Release, Dual Threads (For Use with Transmitters)
Model Process Thread Control Thread
1 1/2" NPT (Standard) 1/2 NPT
2 1/2" NPT 3/4 NPT
3 1/8" NPT ----
Model D Inside Diameter
B 0.188
C 0.215
D 0.250
FittingsAdjustable Spring Loaded / Rev 1.1 www.meas-spec.com 01/06/2015