General Purpose Relays PCB Relays SCHRACK Power PCB Relay RT1 n 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact n DC or AC coil n 5kV/10mm coil-contact, reinforced insulation n Ambient temperature 85C (DC coil) n WG version: product in accordance to IEC 60335-1 n Reflow version: for THR (Through-Hole Reflow) soldering process Typical applications F0144-C Boiler control, timers, garage door control, POS automation, interface modules Zb Approvals Contact Data (continued) VDE REG.-Nr. 6106, cULus E214025, cCSAus 14385 CQC Mechanical endurance 6 Technical data of approved types on request DC coil >30x10 operations 6 AC coil >10x10 operations 6 AC coil, reflow version >5x10 operations Contact Data 12A 16A Contact arrangement 1 form C (CO) or 1 form A (NO) Rated voltage 250VAC Max. switching voltage 400VAC Coil Data Rated current 12A 16A Coil voltage range, DC coil/ AC coil 5 to 110VDC / 24 to 230VAC Limiting continuous current 12A 16A, UL: 20A Operative range, IEC 61810 2 Limiting making current Coil insulation system according UL class F max. 4s, duty factor 10% 25A 30A Breaking capacity max. 3000VA 4000VA Coil versions, DC coil Contact material AgNi 90/10, AgNi 90/10 gold plated Coil Rated Operate Release Coil Rated coil Frequency of operation, with/without load code voltage voltage voltage resistance power -1 2) DC coil 360/72000h VDC VDC VDC 10% mW -1 AC coil 360/36000h 005 5 3.5 0.5 62 403 Operate/release time max., DC coil 8/6ms 006 6 4.2 0.6 90 400 Bounce time max., DC coil, form A/form B 4/6ms 009 9 6.3 0.9 200 400 1) Electrical endurance see electrical endurance graph 012 12 8.4 1.2 360 400 020 20 14.0 2.0 952 420 Contact ratings 024 24 16.8 2.4 1440 400 Type Contact Load Cycles 048 48 33.6 4.8 5520 417 IEC 61810 3 2) 060 60 42.0 6.0 8570 420 RT314 DC-coil A (NO) 16A, 250VAC, cos=1, 85C 30x10 3 2) 110 110 77.0 11.0 28800 420 RT314 DC-coil C (CO) 16A, 250VAC, cos=1, 85C 10x10 3 2) Coil resistance 12%. RT314 DC-coil A (NO) 10A, 400VAC, cos=1, 85C 150x10 3 All figures are given for coil without pre-energization, at ambient temperature +23C. RT114 DC-coil A (NO) 12A, 250VAC, cos=1, 85C 50x10 3 Other coil voltages on request. RT114 AC-coil A (NO) 12A, 250VAC, cos=1, 70C 100x10 UL 508 Coil versions, AC coil 50/60 Hz 3 RT314 A/B (NO/NC) 20A, 250VAC, general purpose, 85C 6x10 Coil Rated Operate Release Coil Rated coil 3 RT334 A (NO) 16A, 250VAC, gen. purpose, 85C 50x10 code voltage voltage voltage resistance power 3 3) RT314 A (NO) 1hp, 240VAC, 40C 1x10 VAC VAC VAC 15% VA 3 3) RT314 A (NO) FLA/LRA, 4.5/13.1A, 480VAC, 70C 100x10 524 24 18.0 3.6 350 0.76 EN60947-5-1 615 115 86.3 17.3 8100 0.76 RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13 6.050 620 120 90.0 18.0 8800 0.75 EN60730-1 700 200 150.0 30.0 24350 0.76 3 RT314 DC-coil A (NO) 12(2)A, 250VAC, 85C 100x10 730 230 172.5 34.5 32500 0.74 1) For reflow solderable versions: actual contact performance may be influenced by the 3) Coil resistance 10%. reflow soldering process. All figures are given for coil without pre-energization, at ambient temperature +23C, 50 Hz. Other coil voltages on request. 1 09-2013, Rev. 0913 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company General Purpose Relays PCB Relays SCHRACK Power PCB Relay RT1 (Continued) Insulation Data Other Data (continued) Initial dielectric strength Terminal type between open contacts 1000V standard version PCB-THT, plug-in rms between contact and coil 5000V reflow version PCB-THR rms Clearance/creepage Mounting distance AC coil: 2.5mm between contact and coil 10/10mm Weight 14g Material group of insulation parts IIIa Resistance to soldering heat THT, IEC 60068-2-20 Tracking index of relay base PTI 250V RTII 270C/10s reflow version PTI 175V RTIII 260C/5s Resistance to soldering heat THR 4) reflow soldering (for reflow version) forced gas convection or 5) vapour phase Other Data temperature profile according EN61730 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Packaging/unit tube/20 pcs., box/500 pcs. refer to the Product Compliance Support Center at 4) infrared heating not allowed www.te.com/customersupport/rohssupportcenter 5) recommended fluid LS/230 Resistance to heat and fire WG version or Reflow version according EN60335, par30 Ambient temperature Accessories DC coil -40 to 85C For details see datasheet Accessories Industrial Power Relay R T AC coil -40 to 70C NOTE: indicated contact ratings and electrical endurance data for direct Category of environmental protection, IEC 61810 wiring of relays (according IEC 61810-1) for relays mounted on sockets standard version R TII - flux proof, RTIII - wash tight deratings may apply. reflow version RTII - flux proof Vibration resistance (functional) form A/form B contact, 30 to 500Hz 20g/5g Shock resistance (destructive) 100g PCB layout / terminal assignment *) With the recommended PCB hole sizes a grid Bottom view on solder pins pattern from 2.5 mm to 2.54 mm can be used. 12A, pinning 3.5mm 12 A, pinning 5 mm 16 A, pinning 5 mm S0418-CB S0418-CN S0418-CA 1 form C (CO) contact 1 form C (CO) contact 1 form C (CO) contact S0163-BG S0163-BC S0163-BE 1 form A (NO) contact 1 form A (NO) contact 1 form A (NO) contact S0163-BH S0163-BD S0163-BF 2 09-2013, Rev. 0913 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2013 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company