General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SRL7 n Low profile relay with force guided contacts according to EN 50205 n 5 form A (NO) + 2 form B (NC) contacts n Reinforced insulation between contact circuits Typical applications Emergency stop or two hand guard safety relays, expansion I/O modules, SRL7 safety control circuits ZT Approvals Coil Data VDE Cert. No. 40036240, UL E214025, TV 968/EL908 Coil voltage range 5 to 110VDC Technical data of approved types on request Operative range, IEC 61810 2 Max. coil power 700mW Contact Data Contact arrangement 5 form A + 2 form B contacts, Coil versions, DC-coil (5 NO + 2 NC) Coil Rated Operate Release Coil Rated coil Rated voltage 250VAC code voltage voltage voltage resistance power Max. switching voltage 400VAC VDC VDC VDC 10% mW Rated current 6A 005 5 3,8 0,5 36 694 2 Sum of the squared currents 72A 006 6 4,5 0,6 51 706 Contact material Ag alloy 009 9 6,8 0,9 116 698 Contact style single contact, force guided 012 12 9 1,2 206 699 type A according to EN 50205 015 15 11,3 1,5 319 705 Min. recommended contact load 5V/10mA 018 18 13,5 1,8 463 700 Initial contact resistance 100m at 1A, 24VDC 021 21 16 2,1 630 700 20 at 10mA, 5VDC 024 24 18 2,4 820 702 -1 Frequency of operation, with/without load 6/30min 036 36 27 3,6 1850 701 6 Mechanical endurance 10x10 operations 048 48 36 4,8 3290 700 060 60 45 6 5140 700 110 110 83 11 17280 700 Contact ratings All figures are given for coil without pre-energization, at ambient temperature +23C. Contact Load Cycles UL508 Insulation Data group A group B NO/NC 6A, 250VAC, general purpose, 85C 6.000 Initial dielectric strength IEC61810 between open contacts 1000Vrms 1000Vrms NO/NC 6A, 250VAC, cosphi=1, 50% DF, 85C 6.000 between contact and coil 4000Vrms 2500Vrms between adjacent contacts 4000Vrms 2500Vrms between group A and group B 4000Vrms Clearance/creepage between open contacts microdisconnection between contact and coil 5.5/5.5mm 3/4mm between adjacent contacts 5.5/5.5mm 3/4mm between group A and group B 5.5/5.5mm Insulation to EN 50178, type of insulation between contact and coil reinforced basic between adjacent contacts reinforced basic between group A and group B reinforced Other Data Ambient temperature -40 to 85C Category of environmental Protection IEC 61 810 RTII Packaging/unit 20 pcs. tray 100 pcs. box 1 10-2014, Rev. 1014 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2014 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SRL7 (Continued) Dimensions PCB layout / terminal assignment Bottom view 7 pole, 5 form A + 2 form B, 5NO + 2NC S0567-DC Product code structure Typical product code SRL 7 52 3 D 024 Type SRL Relay with force guided contacts SRL Version 7 7 pole Contact arrangement 52 5 form A + 2 form B contacts (5 NO + 2 NC) Contact material 3 Ag SnO Coil system D DC coil Coil Coil code: please refer to coil versions table (e.g. 012=12VDC) For versions with different contact configuration or other number of poles please contact your nearest TE contact or partner. 2 10-2014, Rev. 1014 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec- www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2014 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company