Signal Relays AXICOM Cradle P Relay V23003 n Highly reliable multi purpose relay n Great variety of contact arrangements and materials to meet specific applications n Contacts for signal loads and currents up to 5A n Primarily intended for impulse operation n Sockets for easy and quick mounting of relays (see datasheet Accessories) Typical applications applications where the switching status must be maintained, measuring systems Contact Data Product code block 3 B104/B110 B604/B610 C104/C110 C404/C410 F104 to F107 Contact arrangement max. 4 form C (4 CO) contacts, 2 form C (2 CO), 2 form A (2 NO) or 2 form B (2 NC) contacts (see product code table) Max. switching voltage 150VDC 36VDC 150VDC 36VDC 250VDC 125VAC 30VAC 125VAC 30VAC 250VAC Rated current 2A 0.2A 2A 0.2A 5A Limiting continuous current at max. ambient temperature 2A 2A 2A 2A 5A Breaking capacity 35 to 70W 5W, 5VA 35 to 70W 5W, 5VA 50 to 140W see DC load breaking capacity curve below 50VA - 50VA - 500VA Contact material silver, gold-flashed gold F silver, gold-flashed gold F silver, gold-flashed Contact style single contact single contact bifurcated contacts bifurcated contacts single contact Frequency of operation, without load, max. 20 ops./s 20 ops./s 20 ops./s 20 ops./s 20 ops./s 7 7 7 7 8 Mechanical endurance app. 10 ops. app. 10 ops. app. 10 ops. app. 10 ops. app. 10 ops. Max. DC breaking capacity, contact sets B1xx, C1xx Max. DC breaking capacity, contact sets F1xx 1 04-2011, Rev. 0411 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay P V23003 Coil Data and operating range Signal Relays AXICOM Nominal voltage from 6 Vdc to 60 Vdc Typical nominal power consumption, at 20 C 1.5 W Class of the operative range Cradle P Relay V23003 (Continued) 1 acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201 Operating voltage (according to the coil type) max. 73% of the nominal voltage Coil Data Coil Data (continued) Magnetic system polarized, bistable Coil voltage range 6 to 60 VDC, Note: with continuous operation only one winding to be energized within the With continuous operation only one winding at a time may be energized within the specic voltage range. typ. 1500 mW power consumption specified voltage range at a time Max. coil temperature 100C The minimum voltage U and the maximum voltage U only depends on the I II The minimum voltage U and the maximum voltage U depends on the ambient temperature. I II Thermal resistance 50K/W ambient temperature. AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Coil versions, bistable 2 coils U U U20 C k I tamb I I tamb U = U k I tamb I 20 C I tamb Coil Rated Set Reset Limiting Coil Rated coil U U 20 C k II tamb Il II tamb Cradle Relay P V23003 U = U k II tamb Il 20 C II tamb code voltage voltage voltage Set/Reset resistance power tamb Ambient temperature VDCt = VDCAmbient temperature VDC VDC 15% W (set) U Minimum voltage at ambient temperature, tamb I tamb amb 026 6 4.0 4.0 6.7/6.7 24.5/24.5 1.47 U Maximum voltage at ambient temperature, tamb II tamb Coil Data and operating range U = Minimum voltage at ambient temperature, t I tamb amb 025 12 8.0 8.0 13.5/13.5 100/100 1.44 k and k Factors I II U = Maximum voltage at ambient temperature, t II tamb amb 037 24 16.5 16.5 26.5/25.0 400/340 1.44 Nominal voltage k k = Factorsfrom 6 Vdc to 60 Vdc 044 60I and II 44.0 44.0 65.0/65.0 2400/2400 1.5 Insulation Data B1xx,B6xx,C1xx,C4xx F1xx Typical nominal power consumption, at 20 C 064 48 33.5 33.51.5 W 49.0/49.0 1400/1400 1.65 Initial dielectric strength All figures are given for coil without pre-energization, at ambient temperature +23C. between coil / frame 500 VAC 500 VAC rms rms Class of the operative range 1 between contact / contact 500 VAC 1000 VAC rms rms acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201 Operate - negative potential at start of winding Release - plus potential at start of winding Set - negative potential at start of winding between contact / fame 500 VAC 1000 VAC rms rms Operating voltage (according to the coil type) max. 73% of the nominal voltage Initial insulation resistance, at 500 VDC > 106 Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content With continuous operation only one winding at a time may be energized within the specic voltage range. refer to the Product Compliance Support Center at The minimum voltage U and the maximum voltage U depends on the ambient temperature. I II www.te.com/customersupport/rohssupportcenter Ambient temperature -40 to + 70C Category of environmental protection, U = U k I tamb I 20 C I tamb IEC 61810 RT I - dust-protected Degree of protection, IEC 60529 IP 30 U = U k II tamb Il 20 C II tamb Terminal type hand solder terminals, plug-in t = Ambient temperature amb Weight U = Minimum voltage at ambient temperature, t I tamb amb V23003-A0xxx Size I approx. 25g U = Maximum voltage at ambient temperature, t V23003-B0xxx Size II approx. 30g II tamb amb Packaging unit 5 pcs. k k = Factors I and II Ambient temperature C Ambient temperature C Accessories Operate - negative potential at start of winding Reset - plus potential at start of windingRelease - plus potential at start of winding For details see datasheet Cradle Relay, Accessories and Mounting All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 14 Ambient temperature C Ambient temperature C Terminals: coil with 2 windings: winding I: start 3, end 2 All specications subject to change. Consult Tyco Electronics for latest specications. winding II: start 4, end 1 5 of 14 2 04-2011, Rev. 0411 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company