General Purpose Relays Industrial Relays SCHRACK Interface Plug-in Relay XT n 1 pole 16 A, 2 pole 8 A, 1 form C (1 CO) contact or 2 form C (2 CO) contacts n DC or AC coil, sensitive coil 400 mW n Reinforced insulation, protection class II (VDE 0700) n 4kV/8mm dielectric strength between coil and contact n Manual test tab, optionally lockable n Version with mechanical and/or electrical indicator optional n Suitable for use in Tyco Electronics standard RT sockets n Recycleable packaging F0289-B Typical applications Panel boards, mechanical engineering VZL Approvals Coil Data VDE REG.-Nr. B758, UL E214025 , Lloyds 08/20067(E1) Coil voltage range 6 to 110VDC Technical data of approved types on request 24 to 230VAC Operative range, IEC 61810 2 Contact Data XT 1pole XT 2pole Coil insulation system according UL class 155 (F) Contact arrangement 1 form C (CO) 2 form C (CO) Rated voltage 240VAC 240VAC Coil versions, DC coil Max. switching voltage 400VAC 400VAC Coil code Rated Operate Release Coil Rated coil Rated current 16A 8A, UL: 10A STD LED & voltage voltage voltage resistance power 3) 1) 4) Limiting making current, max 4s, df 10% 30A 15A PD VDC VDC VDC 10% mW Limiting short-time current, 30ms 300A 300A 012 LB2 12 8.4 1.2 360 400/10 Switching power 4000VA 2000VA 024 LC4 24 16.8 2.4 1440 400/19 Contact material AgNi90/10 048 LE8 48 33.6 4.8 5520 417/39 1) Min. recommended contact load 12V at 10mA 110 MB0 110 77.0 11.0 28800 420/87 1) Coil resistance 12% Initial voltage drop 30mV at 100mA/6VDC -1 3) Protection diode PD standard polarity: +A1 / -A2 Frequency of operation, with/without load 360/36000h 4) Coil power/optional LED power Operate time, DC coil typ. 8ms typ. 10ms All figures are given for coil without pre-energization, at ambient temperature +23C Release time, DC coil, without PD typ. 6ms typ. 5ms Other coil voltages on request Bounce time, form A/form B, DC coil typ. 4/6ms typ. 4/9ms Contact ratings Type Contact Load Cycles IEC 61810 3 XT3 C (CO) 16A, 250VAC, cos =1, 70C 30x10 3 XT3 A (NO) 16A, 250VAC, cos =1, 70C 50x10 3 XT4 C (CO) 8A, 250VAC, cos =1, 70C 50x10 3 XT4 DC-coil A (NO) 8A, 250VAC, cos =1, 70C 100x10 UL 508 3 XT3 C (CO) 16A, 250VAC, general purpose, 70C 30x10 3 XT4 C (CO) 10A, 250VAC, general purpose, 70C 20x10 3 XT4 C (CO) 8A, 250VAC, general purpose, 70C 30x10 Mechanical endurance 6 DC coil 10x10 operations 6 AC coil 5x10 operations 1 06-2011, Rev. 0611 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company General Purpose Relays Industrial Relays SCHRACK Interface Plug-in Relay XT (Continued) Coil Data (continued) Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Coil versions, AC coil refer to the Product Compliance Support Center at Coil code Rated Operate Release Coil Rated coil www.te.com/customersupport/rohssupportcenter STD LED voltage voltage voltage resistance power Ambient temperature -40 to +70C 50/60Hz 50/60Hz 50/60Hz Cold storage, IEC 60068-2-1 -40C/16h 2) 5) VAC VAC VAC 10% VA Dry heat, IEC 60068-2-2 85C/16h 524 R24 24 18.0/19.2 3.6 350 0.76/0.58 Damp heat cyclic 2) 615 S15 115 86.3/92.0 17.3 8100 0.76/0.58 IEC 60068-2-30, Db, Variant 1 25/55C for 12/12h (2 cycles) 2) 730 T30 230 172.5/184.0 34.5 32500 0.74/0.58 Category of environmental protection 2) Coil resistance 15% IEC 61810 RTII - flux proof 5) Power for optional LED: 24VAC:12mVA, 115VAC: 54mVA, 230VAC: 73mVA Vibration resistance (functional), All figures are given for coil without pre-energization, at ambient temperature +23C form A (NO)/form B (NC) 20/5g (30 to 500Hz) Other coil voltages on request Shock resistance (destructive) 100g Terminal type plug-in Cover retention pull force 100 N push force 100 N Mounting distance 4.5mm, corresponds to dense packing of sockets 6) Manual operation testing and locking position Weight 16g Packaging unit 10/250 pcs. 6) Locking function description If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Delivery status is with testing possibility only, to reach locking position please remove the locking plastic pip according drawing. Insulation Data Initial dielectric strength between open contacts 1000Vrms between contact and coil in combination with socket RT78726 5000Vrms in combination with socket RT78725 4000Vrms between adjacent contacts 2500Vrms Initial surge withstand voltage between contact and coil 5000V (1,2/50s) Clearance/creepage between contact and coil 8/8mm Material group of insulation parts IIIa Tracking index of relay base PTI 175V Accessories For details see datasheet Accessories Interface Plug-in Relay XT Note: indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1) for relays mounted on sockets deratings may apply. Product Sets Complete sets consisting of a relay mounted on a socket see Package XT 2 06-2011, Rev. 0611 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company