Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series Datasheet Key features Wave Inspector controls provide easy navigation and automated search of waveform data 42 automated measurements, and FFT analysis for simplified waveform analysis 16 digital channels (MSO series) Mixed signal design and analysis (MSO series) Automated triggering, decode, and search on parallel buses Per-channel threshold settings Multichannel setup and hold triggering MagniVu High-speed acquisition provides 60.6 ps fine timing resolution on digital channels Optional serial triggering and analysis - automated serial triggering, With the MSO/DPO4000B Mixed Signal Oscilloscope Series, you can 2 decode, and search options for I C, SPI, USB, Ethernet, CAN, LIN, analyze up to 20 analog and digital signals with a single instrument to 2 FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I S/LJ/RJ/TDM quickly find and diagnose problems in complex designs. Bandwidths up to 1 GHz and up to 5X oversampling on all channels ensure you have the TekVPI probe interface supports active, differential, and current performance you need to see fast-changing signal details. To capture long probes for automatic scaling and units windows of signal activity while maintaining fine timing resolution, the MSO/ 10.4 in. (264 mm) bright XGA color display DPO4000B Series offers deep record length of up to 20M points standard on all channels. And with Wave Inspector controls for rapid waveform Small footprint and lightweight Only 5.8 in. (147 mm) deep and 11 lb. navigation, automated serial and parallel bus analysis, limit and mask (5 kg) testing, and automated power analysis your Tektronix oscilloscope provides the feature-rich tools you need to simplify and speed debug of Connectivity your complex design. Two USB 2.0 host ports on the front panel and two on the rear panel for quick and easy data storage and connecting a USB keyboard Key performance specifications USB 2.0 device port on the rear panel for easy connection to a PC or 1 GHz, 500 MHz, 350 MHz, and 100 MHz bandwidth models direct printing to a PictBridge -compatible printer 2 and 4 analog channel models Integrated 10/100/1000BASE-T Ethernet port for network connection Up to 5 GS/s sample rate on all channels and video out port to export the oscilloscope display to a monitor or projector Up to 20 M record length on all channels >340,000 wfm/s maximum waveform capture rate Optional application support Standard passive voltage probes with 3.9 pF capacitive loading and Power analysis 500 MHz or 1 GHz analog bandwidth Limit and mask testing Suite of advanced triggers HDTV and custom video analysis www.tek.com 1Datasheet Need more performance Looking for an MSO at 100 MHz, 350 MHz, 500 MHz or 1 GHz Need an integrated spectrum analyzer Need to analyze analog, digital, and RF simultaneously Consider the MDO4000B Series oscilloscopes, the world s first Mixed Domain Oscilloscope. www.tek.com/MDO4000 Discover Digital phosphor technology with FastAcq enables greater than 340,000 wfms/s waveform capture rate and real-time color-intensity grading. Capture Discovering a device fault is only the first step. Next, you must capture the event of interest to identify root cause. Includes a 16 channel MSO Accurately capturing any signal of interest begins with proper probing. Low- capacitance probes are included with the oscilloscope, one for each analog 3 GHz and 6 GHz integrated spectrum analyzers channel. These industry-first high-impedance passive voltage probes have Simultaneous, time-correlated acquisition of analog, digital and RF less than 4 pF of capacitive loading to minimize the effect of the probe on 20 M record length your circuit s operation, offering the performance of an active probe with the flexibility of a passive probe. A complete set of triggers - including runt, timeout, logic, pulse width/glitch, Comprehensive features speed every stage setup/hold violation, serial packet, and parallel data - help you quickly find of debug your event. With up to a 20M point record length, you can capture many events of interest, even thousands of serial packets, in a single acquisition These oscilloscopes offer a robust set of features to speed every stage of for further analysis while maintaining high resolution to zoom in on fine debugging your design from quickly discovering an anomaly and signal details. capturing it, to searching your waveform record for the event and analyzing its characteristics and your devices behavior. From triggering on specific packet content to automatic decode in multiple data formats, the oscilloscope provides integrated support for the industry s 2 broadest range of serial buses - I C, SPI, USB, Ethernet, CAN, LIN, Discover 2 FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I S/LJ/RJ/TDM. The To debug a design problem, first you must know it exists. Every design ability to decode up to four serial and/or parallel buses simultaneously engineer spends time looking for problems in their design, a time- means you gain insight into system-level problems quickly. consuming and frustrating task without the right debug tools. To further help troubleshoot system-level interactions in complex The industrys most complete visualization of signals provides fast insight embedded systems, the oscilloscope offers 16 digital channels in addition into the real operation of your device. A fast waveform capture rate to its analog channels. Since the digital channels are fully integrated into greater than 340,000 waveforms per second with FastAcq enables you the oscilloscope, you can trigger across all input channels, automatically to see glitches and other infrequent transients within seconds, revealing the time correlating all analog, digital, and serial signals. The MagniVu high- true nature of device faults. A digital phosphor display with color- and speed acquisition on these channels enables you to acquire fine signal intensity-grading shows the history of a signals activity by using color or detail (up to 60.6 ps resolution) around the trigger point for precision timing intensity in areas of the signal that occur more frequently, providing a visual measurements. MagniVu is essential for making accurate timing display of just how often anomalies occur. measurements for setup and hold, clock delay, signal skew, and glitch characterization. 2 www.tek.com