xx P5122 100X Probe 3. Depressthe lockingpininsidethe protective sleeve. Standard Accessories The P5122 Probe is a high voltage probe with 100X The standard accessories included with the probe can be 4. Turn the sleeve and the cable end until the adjustment attenuation and a compensation range of 10 to 25 pF. The reordered as a kit. The kit includes one of each item shown is visible through the opening. probe is designed for use with Tektronix TPS2000 series below. Order Tektronix part number 020-3046-00. oating oscilloscopes with high input impedance (1 M ). The probe has nouser- orTektronix-serviceable parts. Table 1: Probe accessories kit Connecting the Probe to the Oscilloscope Item Description Connect the probe asshowninthe illustrations below. Hook tip 1. Press onto probe tip 2. Squeeze the hook tip to extend 5. Push AUTOSET orotherwiseadjust youroscilloscope the conductive to display a stable waveform. hook 3. Clamp hook 6. Adjustthetrimmerintheprobeuntilyouseeaperfectly onto conductor at-top square wave on the display. (See illustration.) Reference lead, P5122 with hook clip 200 MHz 100X High Voltage Probe 1. Secure lead to probeheadground pin Instructions 2. Connect hook Compensating the Probe clip to circuit WARNING. To avoid electric shock, only use the Due to variations in oscilloscope input characteristics, reference insulated adjustment tool when making compensation the low-frequency compensation of the probe may need adjustments. adjustment after moving the probe from one oscilloscope channel to another. Reference 7. Turnthe sleeve backandlockthe sleeve inplace. lead, with Ifa1kHzcalibratedsquarewavedisplayedat1ms/division WARNING. To avoid electric shock, ensure that the mini-alligatorclip shows signicant differences between the leading and sleeve is locked in the closed position after making 1. Secure lead to trailing edges, perform the following steps to optimize compensation adjustments. probeheadground low-frequency compensation: pin 1. Connect the probetothe oscilloscopechannel that you 2. Squeeze clip plan to use for your measurements. and connect to Connecting the Probe to the Circuit circuit reference 2. Connect the probe to the probe compensation output Use the standard accessories included with the probe to terminals on the oscilloscope front panel. Ground spring connect to your circuit. (See Table 1.) for probe tip WARNING. To avoid electric shock, only connect to the WARNING. Toavoidelectricshockwhenusingtheprobe 1. Press onto Probe Comp signal on the oscilloscope when making or accessories, keep ngers behind the nger guard of probe tip this adjustment. CAUTION. This accessory is rated 30 VAC probe body & accessories (as shown). 2. Probe circuits maximum. Do not use for MAINS connection. with nearby Toreduceriskofshock,whenusingtheprobeonoating reference test measurements,ensurethereferenceleadaccessoriesare points fully mated before connecting the probe to the circuit under test. Adjustment tool Use only this insulated tool for compensation adjustments *P071272001* x 071-2720-01Specications Characteristic Specication EquipmentRecycling. This product complies defects in the probe body, accessories, cable jacket, etc.). with the European Unions requirements Do not use if damaged. Read the caution below if you are using the probe with the Maximum reference lead 600 V CAT II according to Directive 2002/96/EC on waste TPS2000seriesoscilloscope input set to AC coupling. voltage to ground Do Not Operate in Wet/Damp Conditions. electricalandelectronicequipment(WEEE).For Cable length 1.2 m more information about recycling options, check CAUTION. When the oscilloscope input is set to AC Do Not Operate in an Explosive Atmosphere. the Support/Service section of the Tektronix Coupling, donot probe DC levels>300 V orAC signals Keep Product Surfaces Clean and Dry. Web site (www.tektronix.com). less than 1 Hz and >300 V . (See graph below.) RMS Table 3: Environmental specications Safety Terms and Symbols Terms in This Manual. These terms may appear in this manual: Characteristics Description Safety Summary Temperature WARNING. Warning statements identify conditions or Reviewthefollowingsafetyprecautionstoavoidinjuryand +40 C (+104 F) prevent damage to this product or any products connected practices that could result in injury or loss of life. Maximum operating to it. To avoid potential hazards, use this product only as +5 C (+40 F) Minimum operating CAUTION. Caution statements identify conditions or specied. Using the probe or accessories in a manner not 55 C to +75 C (67 F to Nonoperating practices that could result in damage to this product or specied could result in a shock orre hazard. +167 F) other property. Humidity 80% up to +30 C (+86 F), falling To Avoid Fire or Personal Injury Symbols on the Product. These symbols may appear on linearlyto50%at+40C(+104F) For Use With TPS2000 Series Oscilloscopes Only. Do not the product: Altitude oat the reference lead of this probe above the ratedoat 2.0 km (6,600 ft) maximum Operating voltage (600 V RMS CAT II). 15 km (50,000 ft) maximum Nonoperating ConnectandDisconnectProperly. Connecttheprobeoutput Refer to the reference lead derating curve below when tothe measurementinstrument before connectingthe probe makingoating measurements. to the circuit under test. Disconnect the probe input and Table 4: Certications and compliances the probe reference lead from the circuit under test before Characteristics Description disconnectingtheprobefromthemeasurement instrument. Contacting Tektronix EC Compliancewas demonstrated tothefollowing Avoid Electric Shock. To avoid injury orloss oflife, do not Web site: www.tektronix.com Declaration specication as listed in the Ofcial Journal of connect or disconnect probes or test leads while they are of the European Communities: Phone: 1-800-833-9200 connected to a voltage source. Conformity Low Voltage Directive 2006/95/EC: Address: Tektronix, Inc. ObserveAllTerminalRatings. Toavoidreorshockhazard, EN61010-031: 2002 Department or name (if known) observe all ratings and markings on the product. Consult 14200 SW Karl Braun Drive Measurement Category Examples of Products in this the product manual for further ratings information before P.O. Box 500 Category Category making connections to the product. Beaverton, OR 97077 Descriptions CAT III Distribution-level mains, xed USA Avoid ElectricShock. When usingprobe accessories,never installation Email: techsupport tektronix.com exceed the lowest rating of the probe or its accessory, CAT II Local-level mains, appliances, whichever is less, including the measurement category and portable equipment voltage rating. Warranty Information Table 2: Electrical and mechanical specications CAT I Circuits not directly connected to For warranty information, go to Avoid Electric Overload. To avoid injury orre hazard, do mains. Characteristic Specication www.tektronix.com/warranty not apply potential to any input, including the reference Pollution Do not operate in environments where cond Bandwidth DC to 200 MHz (3 dB) inputs, that varies from groundby more than the maximum Degree 2 uctive pollutants may be present (as dened in rating for that input. System attenuation accuracy 100:1 IEC 61010-1). Rated for indoor use only. Compensation range 10 pF25 pF Additional UL61010B-1, FirstEdition & UL61010B-2-031, Avoid Exposed Circuitry and Do not Operate Without Safety First Edition. Covers. Donottouchexposedconnectionsandcomponents System input resistance 100 M Standards when power is present. CAN/CSA-C22.2 No. 1010.1-92, & 4.6 pF System input capacitance CAN/CSA-C22.2 No. 1010.2.031-94 Inspect The Probe And Accessories. Before each use, Maximum tip input voltage 1000 V CAT II IEC61010-031:2002 inspect probe and accessories for damage (cuts, tears, Copyright Tektronix,Inc. All rightsreserved. www.tektronix.com