Digital Storage Oscilloscopes TPS2000B Series Data Sheet Quick setup and operation with autoset menu, autorange, waveform and setup memories, and built-in, context-sensitive Help Backlit menu buttons for high visibility 11 of the most critical automatic waveform measurements Applications Industrial power design, troubleshooting, installation, and maintenance Advanced electronics design, troubleshooting, installation, and maintenance Automotive design and test The TPS2000B Series offers a distinctive range of capabilities in an oscilloscope with controls and menus you will find familiar and easy to use. Education Available in 2- or 4-channel versions, the TPS2000B Series with IsolatedChannel technology provides isolation from ground and isolation between channels allowing you to take measurements with less worry about Make floating and differential measurements - damaging circuitry. Battery power comes standard, making it a natural quickly, accurately, affordably choice for field applications. For work on power electronics, optional software integrates commonly needed power system measurements into Unintentionally grounding a circuit under test is a common cause of poor the instrument, speeding up power analysis and troubleshooting. measurement results and circuit damage. Connecting two or more grounded probes can cause ground loops, and if the current is high enough can result in ruined components and equipment. Most importantly, taking Key performance specifications floating measurements without the proper instruments and probes can pose 100 MHz and 200 MHz bandwidths a safety hazard. 2 or 4 fully isolated and floating channels, plus impedance isolated Tektronix IsolatedChannel technology simplifies floating measurements. external trigger input Unlike ground-referenced oscilloscopes, the TPS2000B input connector shells are isolated from each other and from earth ground. Within the Sample rates up to 2 GS/s real time on all channels specified 600 V maximum float voltage, IsolatedChannel technology RMS 2.5k point record length on all channels keeps current from flowing between the TPS2000B input BNC shells or from any BNC shell to earth. Key features 8 hours of continuous battery operation with two batteries installed, hot swappable for virtually unlimited freedom from AC line power Optional power application software offers the broadest range of power measurements at its price point Quickly document and analyze measurement results with OpenChoice software or integrated CompactFlash mass storage FFT standard on all models Advanced triggers to quickly capture the event of interest Traditional, analog-style knobs and multi-language user interface for easy operationDatasheet Scope/Probe (Attenuation) Maximum Safety Ratings TPS2000 Viewable Signal Reference Float Safety Rating Input Signal Safety Rating On-screen Peak-Peak Voltage On-screen RMS Voltage (Sinusoid centered at 0 V) (Sinusoid centered at 0 V) TPS2000B Input (1X) 600 V CAT II 300 V CAT II 40 V 14.1 V RMS RMS p-p RMS TPP0101 (100 MHz) 30 V 300 V CAT II 400 V 141 V RMS RMS p-p RMS TPP0201 (200 MHz) 30 V 300 V CAT II 400 V 141 V RMS RMS p-p RMS P5150 (50X) 600 V CAT II 1000 V CAT II 2000 V 705 V RMS RMS p-p RMS P5122 (100X) 600 V CAT II 1000 V CAT II 2828 V 1000 V RMS RMS p-p RMS Input signal and float voltage maximum safety ratings. Speed the design and test of industrial power systems and circuits From mobile phones to industrial motor drives, power conversion technology has enabled significant advances in size, performance, and Four IsolatedChannel inputs and isolated external trigger input for quick, accurate, energy efficiency. But even the most basic task of viewing a converter s affordable floating and differential measurements. input and output is complicated by multiple voltage references. Multiple references also make it challenging to view signals from control circuits and Selecting the right probes for the job power circuits at the same time. Using ground-referenced oscilloscopes in these applications, without appropriate differential probes, can damage Different passive probes are available, depending on your application. With circuits and produce bad measurements. For debugging power conversion the included TPP0101/TPP0201 passive probes, the TPS2000B can electronics, IsolatedChannel technology reduces the risk of damage and measure up to 400 V . However, to meet the safety rating of the TPP0101/ p-p unintended circuit interactions. TPP0201, the reference lead of the probe must be maintained within 30 V relative to ground. Because of this, the TPP0101/TPP0201 probes RMS For performing power system measurements, TPS2PWR1 power are well suited for working on digital and analog circuits in which the application software is available as an option for the TPS2000B. It provides maximum voltage never exceeds 30 V . advanced power measurements right on the oscilloscope, at an entry-level RMS price. Measurements on power conversion electronics usually require probes with higher voltage ratings. Tektronix offers two passive probes with insulation systems specifically designed for making floating measurements. With their 100X attenuation, and 1000 VRMS rating, the optional P5122 probes (when coupled with the TPS2000B) are suitable for making measurements on 480 VRMS devices in Category II environments, with a maximum float voltage of up to 600 VRMS relative to earth ground. With the optional P5150 probe, the TPS2000B can measure up to 2000 V , with a maximum p-p float voltage within 600 V of ground. The P5150 is the best choice for RMS making AC-coupled ripple measurements on high-voltage DC power supplies. Please seeCharacteristic for complete safety ratings and specifications. 2 www.tektronix.com