Voltage monitoring in 3-phase mains G2PF...S02 Monitoring relays - GAMMA series Monitoring of phase sequence and phase failure Detection of reverse voltage Connection of neutral wire optional Supply voltage = measuring voltage 2 change-over contacts Width 22.5mm Industrial design Technical data 6 1. Functions Mechanical life: 20 x 10 operations 5 Monitoring of phase sequence, phase failure and detection of return Electrical life: 2 x 10 operations voltage (by means of evaluating the asymmetry) at 1000VA resistive load Switching frequency: max. 60/min at 100VA resistive load 2. Time ranges max. 6/min at 1000VA resistive load Adjustment range (in accordance with IEC 60947-5-1) Start-up suppression time: fixed, max. 500ms Overvoltage category: III (in accordance with IEC 60664-1) Tripping delay: fixed, max. 350ms Rated surge voltage: 4kV 3. Indicators 7. Measuring circuit Green LED ON: indication of supply voltage Measured variable: AC Sinus, 48 to 63Hz Yellow LED ON/OFF: indication of relay output Input: 3(N)~ 115/66V terminals (N)-L1-L2-L3 (G2PF115VS02) 4. Mechanical design (= supply voltage) Self-extinguishing plastic housing, IP rating IP40 3(N)~ 230/132V terminals (N)-L1-L2-L3 (G2PF230VS02) Mounted on DIN-Rail TS 35 according to EN 60715 (= supply voltage) Mounting position: any 3(N)~ 400/230V terminals (N)-L1-L2-L3 (G2PF400VS02) Shockproof terminal connection according to VBG 4 (PZ1 required), (= supply voltage) IP rating IP20 Overload capacity: Tightening torque: max. 1Nm 3(N)~ 115/66V 3(N)~ 132/76V (G2PF115VS02) Terminal capacity: 3(N)~ 230/132V 3(N)~ 264/152V (G2PF230VS02) 1 x 0.5 to 2.5mm with/without multicore cable end 3(N)~ 400/230V 3(N)~ 457/264V (G2PF400VS02) 1 x 4mm without multicore cable end Input resistance: 2 x 0.5 to 1.5mm with/without multicore cable end 3(N)~ 115/66V 5k (G2PF115VS02) 2 x 2.5mm flexible without multicore cable end 3(N)~ 230/132V 10k (G2PF230VS02) 3(N)~ 400/230V 15k (G2PF400VS02) 5. Input circuit Supply voltage: Asymmetry: fixed, typ. 30% 3(N)~ 115/66V terminals (N)-L1-L2-L3 (G2PF115VS02) Overvoltage category: III (according to IEC 60664-1) (= measuring voltage) Rated surge voltage: 4kV 3(N)~ 230/132V terminals (N)-L1-L2-L3 (G2PF230VS02) (= measuring voltage) 8. Accuracy 3(N)~ 400/230V terminals (N)-L1-L2-L3 (G2PF400VS02) Base accuracy: 3% (of maximum scale value) (= measuring voltage) Frequency response: - Tolerance: Adjustment accuracy: - 3(N)~ 115/66V 3(N)~ 99 to 132V (G2PF115VS02) Repetition accuracy: 2% 3(N)~ 230/132V 3(N)~ 198 to 264V (G2PF230VS02) Voltage influence: - 3(N)~ 400/230V 3(N)~ 342 to 457V (G2PF400VS02) Temperature influence: 0.05% / C Rated frequency: 48 to 63Hz Rated consumption: 9. Ambient conditions 3(N)~ 115/66V 3VA (G2PF115VS02) Ambient temperature: -25 to +55C (in accordance with IEC 60068-1) 3(N)~ 230/132V 6VA (G2PF230VS02) -25 to +40C (in accordance with UL 508) 3(N)~ 400/230V 9VA (G2PF400VS02) Storage temperature: -25 to +70C Transport temperature: -25 to +70C Duration of operation: 100% Relative humidity: 15% to 85% Reset time: <100ms (in accordance with IEC 60721-3-3 class 3K3) Residual ripple for DC: - Pollution degree: 3 (in accordance with IEC 60664-1) Drop-out voltage: >20% of the supply voltage Vibration resistance: 10 to 55Hz 0.35mm Overvoltage category: III (in accordance with IEC 60664-1) (in accordance with IEC 60068-2-6) Rated surge voltage: 4kV Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27) 6. Output circuit 2 potential free change-over contacts Rated voltage: 250V AC Switching capacity (distance <5mm): 750VA (3A / 250V AC) Switching capacity (distance >5mm): 1250VA (5A / 250V AC) Fusing: 5A fast acting www.tele-online.comG2PF...S02 Functions Connections Phase sequence monitoring When all the phases are connected in the correct sequence and the measured asymmetry is less than the fixed value, the output relays switch into on-position (yellow LED illuminated). When the phase sequence changes, the output relays switch into off-position (yellow LED not illuminated). Detection of reverse voltage (by means of evaluation of asymmetry) The output relays switch into off-position (yellow LED not illuminated) when the asymmetry between the phase voltages exceeds the fixed value of the asymmetry. An asymmetry caused by the reverse voltage of a consumer (e.g. a motor which continues to run on two phases only) does not effect the disconnection. Dimensions Phase failure monitoring When one of the three phases fails, the output relays switch into off-position (yellow LED not illuminated). RELEASE 2009/07 Subject to alterations and errors www.tele-online.com