Series 114 DPDT Non-Latching Established Reliability / Military Relay CENTIGRID ESTABLISHED RELIABILITY MILITARY DPDT SERIES RELAY TYPE 114 DPDT basic relay 114D DPDT relay with internal diode for coil transient suppression 114DD DPDT relay with internal diodes for coil transient suppression and polarity reversal protection DESCRIPTION The 114 sensitive Centigrid relay retains the same features as the 114 High force/mass ratios for resistance to shock and vibration. standard Centigrid relay with only a minimal increase in profile height Precious metal alloy contact material with gold plating assures excellent (.275 in.). Its .100-inch grid spaced terminals, which preclude the need for high current and dry circuit switching capabilities. spreader pads, and its low profile make the 114 relay ideal for applications where high packaging density is important. The Series 114D and 114DD have internal discrete silicon diodes for coil suppression and polarity reversal protection. The following unique construction features and manufacturing techniques provide excellent resistance to environmental extremes and overall high reliability: By virtue of its inherently low intercontact capacitance and contact circuit losses, the 114 relay has proven to be an excellent ultraminiature RF The 114 feature: switch for frequency ranges well into the UHF spectrum. A typical RF application for the Centigrid relay is in handheld radio transceivers, All welded construction. wherein the combined features of good RF performance, small size, low Advanced cleaning techniques provide maximum assurance of internal coil power dissipation and high reliability make it a preferred method of cleanliness. Transmit-Receive switching Unique uni-frame design providing high magnetic efficiency and mechanical rigidity. ENVIRONMENTAL AND INTERNAL CONSTRUCTION PHYSICAL SPECIFICATIONS Temperature 65C to +125C (Ambient) Vibration 30 gs to 3000 Hz (General Note I) Shock 75 gs, (General Note I) 6ms half sine Acceleration 50 gs Enclosure Hermetically sealed Weight 0.09 oz. (2.55g) max. 2019 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com 114 Page 1 114 122019 Q4Series 114 DPDT Non-Latching Established Reliability / Military Relay SERIES 114 GENERAL ELECTRICAL SPECIFICATIONS (-65 C to 125 C unless otherwise noted. See notes 2 & 3.) Contact Arrangement 2 Form C (DPDT) Rated Duty Continuous Contact Resistance 0.1 ohm max. before life 0.2 ohm max. after life at 1A/28Vdc Resistive: 1 A/ 28 Vdc Inductive: 200 mA/ 28 Vdc (320mH) Contact Load Rating (DC) Lamp: 100 mA / 28 Vdc (320mH) Low level: 10 to 50 A 10 to 50 mV Resistive: 250 mA / 115Vac, 60 and 400 Hz (Case not grounded) Contact Load Rating (AC) 100 mA / 115 Vac, 60 and 400 Hz (Case grounded) 10,000,000 cycles (typical) at low level Contact Life Ratings 1,000,000 cycles (typical) at 0.5 A / 28 Vdc resistive 100,000 cycles min. at all other loads speci ed above Contact Overload Rating 2 A / 28 Vdc Resistive (100 cycles min.) Contact Carry Rating Contact Factory Operate Time 2.0 msec max. at nominal rated coil voltage 114 1.5 ms max. Release Time 114D 4.0 ms max 114DD Contact Bounce 1.5 msec max. Intercontact Capacitance 0.4 pf typical Insulation Resistance 10,000 M min. between mutually isolated terminals Dielectric Strength Atmospheric pressure: 500 Vrms 70,000 ft: 125 (Vrms/60) Negative Coil 114D 1.0 Vdc Max. Transient (Vdc) 114DD 114D Diode P.I.V. (Vdc) 100 Vdc Min. 114DD 114 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2019 TELEDYNE RELAYS 114 122019 Q4