High Voltage Differential Probes HVD3605, HVD3206 HVD310x Key Features 1 kV , 2 kV, 6 kV CAT safety The HVD3000 series high voltage differential probes provide high CMRR rated models over a broad frequency range to simplify the measurement challenges Worlds only 1500 V safety dc found in noisy, high common-mode power electronics environments. rated probe per IEC/EN 61010- The probes design is easy-to-use and enables safe, precise high voltage 031:2015 floating measurements. Widest differential voltage ranges available Exceptional Common-Mode Widest Application Coverage Rejection Ratio The HVD3000 series of high voltage Exceptional common-mode The CMRR for the probes is rejection ratio (CMRR) across a differential probes cover the fullest broad frequency range exceptional out to very high range of applications, from 120/240V frequencies, greatly improving switch-mode power supplies through 1% gain accuracy measurement capability in the noisy, 600 V class and 5 kV class electrical High offset capability at both high common-mode environments apparatus, Each model has the best high and low attenuation found in power electronics. The high available gain accuracy, widest differ- AC and DC coupling CMRR combined with low probe ential and offset voltage range, and ProBus active probe interface noise and high offset capability superior CMRR. with automatic scaling provides superior measurement Worlds Only 2 kV Rated Probe capabilities compared to other HV Auto-z ero capabilities The HVD3206 is specifically designed differential probes. Wide oscilloscope compatibility for 1500 V solar photovoltaic (PV) dc High Precision Measurements measurements per the IEC/EN 61010- HVD3000 series probes provide 1% 031:2015 standard. gain accuracy enabling precise voltage Complete Probe Integration measurements. AutoZero capability The ProBus interface provides power ensures further measurement and communication to the probe precision by allowing small offset eliminating the need for a separate drifts to be calibrated out of the power supply or batteries. Attenuation measurement. is automatically selected based on oscilloscope gain range (V/div) setting. WIDE APPLICATION COVERAGE - 600 V TO 5 KV APPARATUS 600 V Class, 3-phase Electrical Apparatus The HVD310x probes are available in a range of bandwidths from 25 to 120 MHz with standard 2 meter cable (6 meter cable model available). All probes have industry best CMRR for best noise-immunity, are guaranteed to 1% gain accuracy, and have the industrys widest differential voltage range in a 1 kV rated high voltage differential probe. Only 1 kV safety rated probe that serves the full 600 V class requirement 1500 V differential range with industrys best overshoot measurement capability (to 2000 V ) pk Industrys best offset capability (1500 V) when used with HDO Series oscilloscopes Bandwidth rating up to 120 MHz Sinusoidal AC DC Bus Drive / Inverter 6 meter cable model available Line Input Voltage Pulse-Width Modulated (PWM) Output (HVD3106-6M) V V (Rated) V (with Overshoot)* pk-pk pk pk V or rms V dc Line- Line- Line- V Line-Line Line-Line Line-Line ac Models a vailable without accessories Neutral Neutral Neutral for a lower cost (HVD310x-NOACC) 400 1131 653 566 566 327 849 491 480 1358 784 679 679 392 1019 588 600 1697 980 849 849 490 1274 735 690 1952 1127 976 976 563 1464 845 *Based on 50% overshoot condition 5 kV Class, 3-phase Electrical Apparatus The HVD3605 probe is safety-rated for 6000 V and 8485 V(DC + peak AC) for full coverage of 5 kV class apparatus. The rms probe has ample 100 MHz of bandwidth, is standard with a 6 meter cable, is guaranteed to 1% gain accuracy, has excellent CMRR, and has the industrys widest differential voltage range. Only probe that permits AC Line, DC Bus, and Drive/Inverter output voltage probing through 4160 V apparatus ratings Industrys best overshoot measurement capability (to 7600 V ) pk Industrys best offset capability (6000 V) when used with Sinusoidal AC DC Bus Drive / Inverter HDO Series oscilloscopes Line Input Voltage Pulse-Width Modulated (PWM) Output V V (Rated) V (with Overshoot)* pk-pk pk pk Standard 6 meter cable V or rms V dc Line- Line- Line- V Line-Line Line-Line Line-Line ac Neutral Neutral Neutral 2400 6788 3920 3395 3395 1960 4244 2450 3300 9334 5388 4666 4666 2694 5833 3368 4160 11766 6794 5884 5884 3397 7355 4246 *Based on 25% overshoot condition 2