Series KA/LA 2.0 to 7.5A, 250 Vrms Optically Isolated AC Solid-State Relay Part Number* Relay Description KA00HF 2 A, 250 Vrms, AC Solid-State Relay KA58HF 2 A, 250 Vrms, AC Solid-State Relay with Thermal Protection and Thermal TRIP Status LA00HL 7.5 A, 250 Vrms, AC Solid-State Relay LA58HL 7.5 A, 250 Vrms, AC Solid-State Relay with Thermal Protection and Thermal TRIP Status FEATURES/BENEFITS * The Y suffix denotes parameters tested to MIL-PRF-28750 test methods. Available with thermal protection The W suffix denotes parameters tested to Teledyne specifications. and thermal TRIP status: Provides self-protection from thermal ELECTRICAL SPECIFICATIONS runaway conditions and indicates protection state for system BIT. (-55C TO +110C UNLESS OTHERWISE SPECIFIED) Optical Isolation: Isolates control INPUT (CONTROL) CHARACTERISTICS elements from load transients with reduced EMI. 2 Terminal Configuration (See Fig. 1) Min Max Units Fully Floating Output: Eliminates Input Voltage (See note 2) 3.8 32 Vdc ground potential loops and allows the output to sink or source current. Input Current (See Figure 1) Buffered Control: Relay can be V = 5 Vdc 15 mA dc controlled directly from TTL or IN CMOS logic circuits. Turn-Off Voltage (Guaranteed Off) 1.5 Vdc Integral Snubber Circuit: Enhances dV/dt capability while minimizing Turn-On Voltage (Guaranteed On) 3.8 Vdc EMI. Reverse Voltage Protection -32 Vdc DESCRIPTION The Series KA/LA solid-state relays INPUT (CONTROL) CHARACTERISTICS (SSRs) is designed for use in AC 3 Terminal Configuration (See Fig. 1) Min Max Units power switching applications where safety and reliability are primary Bias Voltage (See note 2) 3.8 32 Vdc concerns. These SSRs are rated for load voltages up to 250 Vrms from 40 Bias Current (V =32 Vdc) 16 mA to 440 Hz and are ideal for resistive IN and reactive loads with power factors Control Voltage Range 0 18 Vdc as low as 0.2. Inverse parallel SCRs are configured for zero voltage turn on. Control Current (at 5 Vdc) 250 Adc Optical isolation to 1250 Vrms between the control (input) and load (output) Turn-On Control Voltage 0.3 Vdc allows the load to be safely controlled by logic circuitry. The KA/LA series is Turn-Off Control Voltage 3.2 Vdc available with thermal protection and thermal TRIP status. In case of a OUTPUT (LOAD) SPECIFICATIONS thermal runaway condition, the SSR will shut down the output switch and Min Max Units latch off until the input is reset and the junction temperature returns to a safe level. When the output does latch off, Load Voltage 20 250 Vrms the TRIP status line will yield a logic level output indicating the protection Frequency Range 40 440 Hz state of the SSR. This feature provides the user with failure mode indication Continuous Load Current (See Figure 3) while enhancing the system diagnostic KA and LA without Heat Sink 2.0 Arms capability. These SSRs are available to LA with Heat Sink 7.5 Arms the Y screening level of MIL-PRF- 28750 and are packaged in low-profile Output Voltatge Drop 1.2 Vrms hermetically sealed cases. KA/LA 78 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2002 TELEDYNE RELAYS KA/LA 072002 Q1Series KA/LA OUTPUT (LOAD) SPECIFICATIONS BLOCK DIAGRAM Min Max Units Off-State Leakage Current 10 mA (250 Vac, 400 Hz) Turn-On Time 1/2 Cycle Turn-Off Time 1 Cycle Transient Voltage (5 sec, 25C) +500 V pk Zero Voltage Turn-On Point +15 V pk dv/dt 100 V/s Surge Current MIL-PRF-28750 Load Power Factor 0.2 MECHANICAL SPECIFICATIONS 9 Insulation Resistance 500 Vdc 10 Ohm Input to Output Capacitance 15 pF Dielectric Withstanding Voltage (60Hz) 1250 Vrms o Junction Temperature at Rated Current (T Max) 125 C J o Thermal Resistance Junction to Ambient ( )30 C/W JA o Thermal Resistance Junction to Case ()5 C/W JC STATUS OUTPUT TRUTH TABLE Status Control Output Output State Input (Load) State Off (High) Low On On (Low) Low Tripped (Off) Off (High) High Off On (Low) High Non-applicable condition STATUS OUTPUT SPECIFICATIONS Min Max Units Status Supply Voltage 32 Vdc Status OFF Leakage Current 32 Vdc 10 Adc Status Sink Current (V 0.4 Vdc) 10 mAdc so DIMENSIONS ARE SHOWN IN INCHES Status ON State Voltage 10mAdc 0.4 Vdc (MILLIMETERS) 2002 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com KA/LA 79 KA/LA 072002 Q1