Series LS 30A to 600 Vac SIP Package DC Control Part Number Description LS24D16C-HS1 16A, 240 Vac LS60D22C-HS1 22A, 600 Vac LS24D27C 27A, 240 Vac LS60D30C 30A, 600 Vac Part Number Explanation LS 24 D 16 C 2 3 Series Switch Type Control Range FEATURES/BENEFITS 1 Line Voltage Output Current Amps Industry standard package Designed for external heat-sink attachment NOTES 1) Line Voltage (nominal) 24 = 240 Vac 60 = 600 Vac Over-sized thyristor ratings 2) Switch Type: D = Zero-cross turn-on Direct-copper bonding technology 3) Control Range: C = 4-14 Vdc DESCRIPTION MECHANICAL SPECIFICATION These solid-state single inline package (SIP) relays are designed for mounting on printed circuit .01 (0.3) Hot surface: 1.48 (37.6) boards. The Series LS relays facilitate heat sinking by providing an interface surface. The relays are designed with 16A, 25A and 50A thyristors. They can switch loads with high starting currents. The nominal 43 2 1 switched currents depend on the size of the heat sink and are limited by the cross section of the tracks of 1 .07 .006 .31 0.2 (5.08) 0.4 (1.7 0.15) the printed circuit (mainly 25A/30A). The relays use a (7.83) 0.5 (12.7) (10.16) .30 (7.83) 1.71 (43.6) direct-bonded copper substrate for thermal ef ciency, .25 (6.3) thermal stress performance and long-life expectancy07 (1.7) APPLICATIONS Top view 0.1 (2.54) Hole .06 (1.6) Motor control Pumps, reversing, integration of relays in terminal boxes WEIGHT: 0.53 oz. (15g) TOLERANCES: .007 (0.2mm) Lamp control Infrared drying, traf c lights, theater Figure 1 - LS relays dimensions in inches (mm) lighting (See Figure 12 for LS with HS1) APPROVALS TYPICAL APPLICATION All models are UL recognized. L L 1 1 UL File Number: E128555. MOV on BLOCK DIAGRAM the PCB Load Or SSR 3 + MOV on Ic the PCB Rc 1 ~ Vc Load SSR 4 N N 2 ~ Figure 2 LS relays Figure 3 LS relays 2016 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com LS Page 1 LS 092014 Q3 .96 (24.5) .02 (.55) Hot surface: .16 (4) .69 (17.5) .06 x .06 .30 (7.6) (1.5 x 1.5)Series LS 30A to 600 Vac SIP Package DC Control INPUT (CONTROL) SPECIFICATION CONTROL CHARACTERISTIC 30 Min Max Units 28 26 Control Range 4 14 Vdc 24 Input Current Range 6.5 30 mAdc 22 20 Must Turn-off Voltage 1 Vdc 18 16 Input Resistance (Typical) 440 Ohms 14 12 10 8 6 OUTPUT (LOAD) SPECIFICATION 4 2 Min Max Unit 0 01 2 34685 7 9 10 11 12 13 14 15 16 Operating Range Control Voltage (V) LS24 12 280 Vrms Figure 4 LS relays LS60 24 600 Vrms THERMAL CHARACTERISTICS Peak Voltage 20 ~ FW150 ( 3C/W) ~ FW100 LS24D16C 600 Vpeak (~4C/W) ~ Full on state 15 LS60D22C 1200 Vpeak 6C/W 10 Load Current Range LS24D16C .005 16* Arms 5 LS60D22C .005 25* Arms Without heat sink LS24D27C .005 30* Arms 0 LS60D30C .005 30* Arms 0 5 10 15 20 010 20 30 40 50 60 70 80 90100 *Limited by the heat sink Load Current (Arms) Ambient Temperature (C) Figure 5a LS24D16C relay Maximum Surge Current Rating (Non-Repetitive) 35 (See Figure 6) 30 ~ Full on state FW150 (~3C/W) LS24D16C 160 Apeak FW100 25 (~4C/W) ~ LS60D22C 300 Apeak 20 6C/W LS24D27C 600 Apeak 15 LS60D30C 1000 Apeak 10 5 Without heat sink On-State Voltage Drop 1.6 V 0 0 5 10 15 20 25 010 20 30 40 50 60 70 80 90100 Load Current (Arms) Ambient Temperature (C) Zero-Cross Window (Typical) 12 V Figure 5b LS60D22C relays 40 Off-State Leakage Current (60Hz) 1 mA Full on state ~ FW150 (~3C/W) FW100 30 ~ (~4C/W) 20 6C/W 10 Without heat sink 0 0 5 10 15 20 25 30 35 0 10 20 30405060708090 100 Load Current (Arms) Ambient Temperature (C) Figure 5c LS24D27C, LS60D30C relays LS Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2016 TELEDYNE RELAYS LS 092014 Q3 Power Dissipation (W) Power Dissipation (W) Power Dissipation (W) Input Current (mA)