Series S Single Output to 660 Vac AC/DC Control Part Numbers 3 Package & Line Switch Output Feature 1 2 Chip Type Voltage Type Current S 24 R 12 -22 D 25 A 40 S 48 R 25 -22 D 50 125 Part Number Example: S48A25-22 S 60 D 50 NOTES 1) Line Voltage (nominal): 24 = 240 Vac 48 = 480 Vac 60 = 600 Vac 125 2) Switch Type: R = Random turn-on D = Zero-cross turn-on For RoHS Compliant Contact Factory A = AC control, Zero-cross turn-on 3) Feature: -22 = 24 Vac control. Available on A type 240 Vac, 25 and 40A models and A type 480 Vac, 25, 50, 125A models MECHANICAL SPECIFICATION 1.06 (27) (p .02) ( p 0.5) .9 (22.8) 1.1 (28) FEATURES/BENEFITS .77 (19.6) .19 (4.7) M4 Industry standard package Internal snubber (except S60 models) Designed for all types of loads AC or DC control available 1~ 2~ Excellent thermal performance Tight zero-cross window for low EMI High immunity to surges 4- 3+ DESCRIPTION The Series S single-phase relays are designed for all types of loads. The design incorporates an SCR 1.02 (25.8) or triac output. The relays utilize optical isolation to 1 (25.4) protect the control from load transients. All contain an 1.75 (44.5) M3 internal snubber for output protection. High-current TOLERANCES: p .01 (0.3) WEIGHT: 3.18 oz. (90g) models are excellent for motor and phase angle control. Figure 1 S relays, 1295 A dimensions in inches (mm) APPLICATIONS 125A model uses larger M5 output screw terminals Heating control TYPICAL APPLICATION Motor control Line Voltage Uninterruptible power supplies Light dimmers Industrial and process control Line Protection On/Off controls of AC equipment 4 1 APPROVALS - S24 and S48 models are UL recognized. Control UL File Number: E128555. + 3+ 2 * 1-2 can be changed * SSR must be mounted on a heat sink LOAD Figure 2 S relays 2014 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com S Page 1 S 072014 Q3 2.29 (58.2) .26 (7.5) 1.7 (43.2) 1.87 (47.6) .2 (5.1)Series S Single Output to 125A 660 Vac AC/DC Control INPUT (CONTROL) SPECIFICATION CONTROL CHARACTERISTICS Min Max Units 30 Control Range 28 26 S24 R 3 30 Vdc 24 22 D 4 30 Vdc 20 18 S48 R 4 30 Vdc 16 14 D 5 30 Vdc 12 10 S60 D 5 30 Vdc 8 6 SxxA A 90 240 Vac/Vdc 4 2 Sxxxxx-22 A 17 80 Vac/Vdc 0 0214 6 801214 16 18 20 22 24 26 28 30 Control Voltage (V) Input Current Range Figure 3b S24D/R relays S R/D 3 30 mA S A 3 8 mA 8 Sxxxxx-22 A 5.6 26 mA 6 Must Turn-Off Voltage 4 S R/D 1 Vdc S24 A 15 Vac 2 S48 A 1 Vac Sxxxxx-22 3 Vac 0 0 20 40 60 80 100 120 140 160 180 200 220 240 Control Voltage (V) Input Resistance (Typical) Figure 3c S24A and S48A relays S R/D 1000 Ohms S A 30,000 Ohms 30 Sxxxxx-22 3000 Ohms 25 20 Reverse Voltage Protection 15 S R/D 30 V 10 S A NA 5 0 0 10 20 30 40 506070 80 CONTROL CHARACTERISTICS Control Voltage (V) Figure 3d Sxxxxx-22 relays 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 0214 6 801214 16 18 20 22 24 26 28 30 Control Voltage (V) Figure 3a S48R, S48D and S60D relays S Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2014 TELEDYNE RELAYS S 072014 Q3 Input Current (mA) Input Current (mA) Input Current (mA) Input Current (mA)