Series CD 2A, 60Vdc Optically Isolated, Short-Circuit Protected DC Solid-State Relay Part* DESC Drawing Relay Description Number Number CD00CFW Basic Solid-State Relay (SSR) CD00CFY 90091-008 CD01CFW SSR with Control Status CD01CFY 90091-006 FEATURES CD20CDW SSR with Short-Circuit Protection Available with short circuit/current overload protection CD20CDY 90091-004 Available with input status monitor CD21CDW SSR with Short-Circuit Protection TTL and CMOS compatible control Low ON resistance power FET output and Control Status CD21CDY 90091-002 Fast switching speed * The Y suffix denotes parameters tested to MIL-PRF-28750 specifications. Meets 28 Vdc system requirements of The W suffix denotes parameters tested to Teledyne specifications. MIL-STD-704 For surface mount (SMT), add S prefix to part number. Example: Optical isolation SCD00CFW Low profile hermetic ceramic package Built and tested to the requirements of ELECTRICAL SPECIFICATIONS MIL-PRF-28750 (-55C TO +105C UNLESS OTHERWISE NOTED) DESCRIPTION INPUT (CONTROL) SPECIFICATION This all solid-state relay utilizes the When used in 2 terminal configuration latest technology to provide a low ON resistance. The control (input) and load (TTL or direct control) (See Fig. 1) Min Typ Max Units (output) are optically isolated to protect input logic circuits from voltage and Input Current V = 5 Vdc (See Fig. 2) 14 15 mA IN current transients which can occur on the output supply. The optical isolation Turn-Off Voltage (Guaranteed Off) 1.5 Vdc also provides a full floating output, thus allowing the load to be connected to Turn-On Voltage (Guaranteed On) 3.8 Vdc either output terminal. The control circuit is buffered to enable the relay to be Reverse Voltage Protection -32 Vdc driven directly from standard CMOS or open collector TTL logic circuits. Input Supply Range (See Note 4) 3.8 6 Vdc Available options include short circuit and current overload protection, which INPUT (CONTROL) SPECIFICATION provides complete protection for both the relay and the system wiring. This When used in 3 terminal configuration feature not only provides protection (CMOS or open collector TTL) (See Fig. 1) Min Typ Max Units should a short or overload occur while the relay is on, but will also provide Control Current protection should the relay be switched V = 5 Vdc 250 A into a short. In either case, the relay will CONTROL sense the short circuit condition and V = 18 Vdc 1 mA CONTROL then block it indefinitely until the short is removed and the unit is reset by cycling Control Voltage Range 0 18 Vdc the input control. The second option is a status output, which provides a built-in- Bias Supply Voltage (See Note 4) 3.8 6 Vdc test function. This feature checks the input circuitry of the relay and provides a Bias Supply Current V = 5 Vdc 14 15 mA BIAS logic (0) low when the input circuit is turned on and operational. Both options Turn-Off Voltage (Guaranteed Off) 3.2 Vdc are available either together or separately as standard features. Turn-On Voltage (Guaranteed On) 0.3 Vdc 2002 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com CD 41 CD 072002 Q1Series CD OUTPUT (LOAD) SPECIFICATIONS BLOCK DIAGRAM (BOTTOM VIEW) (See Note 2) Min Typ Max Units Continuous Load Current (See Fig. 3) CD20CD 1.0 Adc CD21CD 1.0 Adc CD00CF 2.0 Adc CD01CF 2.0 Adc Leakage Current V = 60 Vdc 40 Adc LOAD Output Voltage Drop CD20CD 0.6 Vdc CD21CD 0.6 Vdc CD00CF 0.75 Vdc CD01CF 0.75 Vdc Continuous Operating Load Voltage 60 Vdc Transient Blocking Voltage (See Note 3) 80 Vdc ON Resistance Rds (on) at T = 25C I = 100 mAdc (See Fig. 4) J LOAD CD20CD 0.36 0.45 Ohm MECHANICAL SPECIFICATIONS CD21CD 0.36 0.45 Ohm CD00CF 0.16 0.22 Ohm CD01CF 0.16 0.22 Ohm Turn-On Time (See Fig. 5) 1.5 ms Turn-Off Time (See Fig. 5) 0.25 ms Electrical System Spike 600 Vdc Output Capacitance at 25 Vdc, 100 KHz 475 pF Input to Output Capacitance 10 pF Dielectric Strength 1000 Vac 9 Insulation Resistance 500 Vdc 10 Ohm Maximum Junction Temperature (T Max) J CD00 150 C CD01 150 C Thermal Resistance Junction to Ambient ( )80 C/W JA Thermal Resistance Junction to Case ()20 C/W JC STATUS OUTPUT SPECIFICATIONS (CD01CF AND CD21CD) Min Typ Max Units Status Supply Voltage (See Note 7) 30 Vdc Status Leakage Current 15 Vdc 4 Adc Status (sink) Current (V < 0.3 Vdc) 2 mAdc SO CD 42 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2002 TELEDYNE RELAYS CD 072002 Q1