NEW Series SS Output to 75A, 510 Vac Solid-State Relay with Diagnostic FEATURES/BENEFITS Zero switching AC output DC control input Fault detection: line or load open short-circuit output Solid-state N.C. status output without power supply Control and status LED indicators Terminal block for control and status output connections Part Number Description MECHANICAL SPECIFICATION 1.063 (27) SS24D50 50A, 70280 Vac with diagnostic 0.02 0.898 0.5 SS24D75 75A, 70280 Vac with diagnostic (22.8 ) 0.89 (28) 0.77 SS48D50 50A, 150510 Vac with diagnostic 4.7 M4 (19.6) SS48D75 75A, 150510 Vac with diagnostic 1 L1 2 T1 Part Number Explanation 150510 Vac 75A with heat sink SS 24 D 50 status control N.C. output 832 Vdc max 30V 0.1A A2 A1 3 4+ 5 6+ 2 Series Switch Type 1 Line Voltage Output Current Amps ELECTRICAL SPECIFICATIONS 1.14 (29) 1.38 (35) (+25C ambient temperature unless otherwise specified) 1.75 (44.5) TOLERANCES: 0.01 (0.3) INPUT (CONTROL) SPECIFICATIONS WEIGHT: 3.52 oz. (100g) Min Max Units Figure 1 Control Range SS24 7 32 V BLOCK DIAGRAM Mains SS48 8 32 V 150510V Ic A1 1 L1 4+ Input Current Range Fuse Control Vc SS24 4 30 mA 3 A2 green SS48 4 28 mA Vs Id 6+ Load yellow Vds 5 Must Turn-Off Voltage 2 T1 Status output 0V/Vs SS24 3 V Without faults, the status output is normally closed (NC) SS48 4 V Figure 2 Input Resistance (Typical) All relays 1000 Ohms STATUS OUTPUT SPECIFICATIONS Min Max Units Reverse Voltage Protection Supply Voltage 1 32 V All relays 30 V Output Current 0 0.1 A On Resistance 2 Ohms Maximum Cable Length 40 m 2003 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com SS Page 1 SS/052002 Q1 2.29 (58.2) 1.74 (44.2) 0.24 (6) Rc 1.87 (47.6) 0.20 (5.1)NEW Series SS NEW Series SS Output to 75A, 510 Vac Output to 75A, 510 Vac Solid-State Relay with Diagnostic Solid-State Relay with Diagnostic ELECTRICAL SPECIFICATIONS OUTPUT (LOAD) SPECIFICATIONS (Continued) (+25C ambient temperature unless otherwise specified) Min Max Units OUTPUT (LOAD) SPECIFICATIONS 2 I t for Match Fusing (<8.3 ms) Min Max Units 2 50A output current 1500 A S Operating Range 2 75A output current 5000 A S SS24 70 280 Vrms SS48 150 510 Vrms Operating Frequency Range All relays 47 63 Hz Peak Voltage SS24 600 Vpeak CONTROL CHARACTERISTIC SS48 1200 Vpeak 30 Load Current Range 25 50A output current .1 50 Arms 20 75A output current .1 75 Arms 15 Maximum Surge Current Rating (Resistive) 50A output current 550 A 10 75A output current 1000 A 5 On-State Voltage Drop 0 50A output current 1.45 V 0 5 10 15 20 25 30 35 Control Voltage (V) 75A output current 1.35 V Figure 3 Zero-Cross Window (Typical) SURGE CURRENT All relays 14 V 600 Non-Repetitive Off-State Leakage Current (60 Hz) 400 All relays 5 mA 200 Repetitive with initial Tj = 70C Turn-On Time (60 Hz) 0 All relays 8.3 ms 0.01 0.1 1 10 t(s) Figure 4a 50A relays Turn-Off Time (60 Hz) All relays 8.3 ms 1500 Non-Repetitive 1000 Off-State dv/dt All relays 500 V/s 500 Repetitive with initial Tj = 70C 0 Maximum di/dt (Non-Repetitive) 0.01 0.1 1 10 t(s) All relays 50 A/s Figure 4b 75A relays SS Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2003 TELEDYNE RELAYS 2003 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com SS Page 3 SS 052003 Q1 SS/052002 Q1 Apeak Apeak Input Current (mA)