T3DSO1000/T3DSO1000A Data Sheet Oscilloscopes Debug with Con dence 100 MHz 350 MHz Tools for Improved Debugging Long Capture Up to 28Mpts interleaved. Capture more time and show more waveform detail. Math and Measure 7 basic math functions plus FFT Extract results from waveforms and measurements. and 38 automatic measurement parameters. Connectivity USB for mass storage, printing and Save data for external analysis and screen images for reports. PC control, plus LAN for fast data transfer. Serial Bus Trigger and Decode I2C, SPI, UART, Debug serial buses directly in your Oscilloscope. RS232, CAN, LIN. Waveform Sequence Recorder record and play back Replay the changing waveform history. up to 80,000 waveforms. Optional MSO 16 Digital Channels Add mixed signal debugging to your Oscilloscope. (4 channel and A series only). Key Speci cations Bandwidth 100 MHz, 200, 350 MHz Channels 2 or 4 Memory up to 14 Mpts/Ch (28 Mpts interleaved) Sample Rate up to 1 GS/s / 2 GS/s interleaved Display 7 Bright TFT LCD (800 x 480) Connectivity USB Host, USB Device, LANPRODUCT OVERVIEW T3DSO1102: 2 Channel 100 MHz T3DSO1104: 4 Channel 100 MHz T3DSO1202A: 2 Channel 200 MHz T3DSO1204: 4 Channel 200 MHz T3DSO1302A: 2 Channel 350 MHz Teledyne Test Tools new T3DSO1000 Oscilloscopes feature two channel and four channel models. The two channel models are available with 100 MHz, 200 MHz and 350 MHz analog bandwidths, a single ADC with up to 2 GSa/s maximum sample rate, and memory up to 28 Mpts. The four channel scope is available in 100 and 200 MHz models and incorporates two 1 GSa/s ADCs and two 14 Mpts memory modules. When all channels are enabled, each channel has sample rate of 500 MSa/s, or 1 GS/s for the A series, and a standard record length of 7 Mpts, or 14 Mpts for the A Series. When only a single channel per ADC is active, the maximum sample rate and the maximum record length are doubled. For ease-of-use, the most commonly used functions can be accessed with its user-friendly front panel design. The T3DSO1000 series employs a new generation of high Another powerful addition is the new 1millionpoint speed display technology that provides excellent signal FFT math function that gives the T3DSO1000 very high clarity, fi delity and performance. The system noise floor is frequency resolution when observing signal spectra. The also lower than similar products in the industry. It comes new digital design also includes a hardware co-processor with a minimum vertical input range of 500 uV/div, an that delivers measurements quickly and accurately innovative digital trigger system with high sensitivity and without slowing acquisition and front-panel response. low jitter, and a waveform capture rate of 400,000 frames/ The features and performance of Teledyne Test Tools sec (sequence mode). The T3DSO1000 also employs T3DSO1000 family cannot be matched in this price class. a256-level intensity grading display function and a color The four channel and A series includes even more temperature display mode not found in other models in functions, including: searching and navigating, on-screen this class. Teledyne Test Tools latest oscilloscope offering Bode plot, 16 digital channels (Option), an external USB supports multiple powerful triggering modes including powered 25MHz isolated AWG module (Option), a USB serial bus triggering. Serial bus decoding for IIC, SPI, UART, WIFI adapter (Option), and an embedded application that CAN, LIN bus types is included. The models also include allows remote control via web browser. History waveform recording, and sequential triggering that enable extended waveform recording and analysis. Intelligent trigger: Edge, Slope, Pulse Width, Window, Key Features Runt, Interval, Time out (Dropout), Pattern 100 MHz, 200 MHz and 350 MHz bandwidth models Serial bus triggering and decoding (Standard), supports Two channel series have one ADC, four channel series protocols IIC, SPI, UART, RS232, CAN, LIN have two ADCs. When all channels are enabled, each Video trigger, supports HDTV channel has a maximum sample rate of 500 MSa/s Low background noise with voltage scales from (1 Gsa/s for the A series). When a single channel 500V/div to 10 V/div per ADC is active, it has sample rate of 1 GSa/s 10 types of one-button shortcuts, supports Auto Setup, (2 Gsa/s for the A Series) Default, Cursors, Measure, Roll, History, Display/Persist, The newest generation of high speed display Clear Sweep, Zoom and Print Segmented acquisition technology (Sequence) mode, divides the maximum record length Waveform capture rate up to 100,000 wfm/s into multiple segments (up to 80,000), according to (normal mode), and 400,000 wfm/s (sequence trigger conditions set by the user, with a very small dead mode) time segment to capture the qualifying event. Supports 256-level intensity grading and color History waveform record (History) function, maximum display modes Record length up to 28 Mpts recorded waveform length is 80,000 frames. Digital trigger system 2