EN100/EN150 Environmental Meters with 11 Functions Environmental meters measuring multiple indoor and outdoor conditions. EN150 Air Velocity/Air Flow Humidity/Temperature Light Level (EN100) UV Level (EN150) EN100 Common Features Model EN100 Additional Functionality Built-in sensors measure 11 environmental conditions Built-in Light sensor measures light level including Air Velocity, Air Flow, Temperature, Humidity, Auto-rotating display depending on function Wet Bulb, Dew Point, Heat Index, Wind Chill, Model EN150 Additional Functionality Barometric Pressure, and Altitude Built-in UV sensor measures UV light level Natural Field replaceable low friction vane wheel improves Sunlight Measurements air velocity accuracy Backlit LCD display (auto off after 5 seconds) Data Hold freezes displayed reading Auto power off (with disable feature) Complete with built-in multiparameter sensors, wrist strap, and CR2032 battery. (Optional Pt -1000 probe, EN100-TP, for external temperature measurement) EN100-TP Ordering EN100 ............... Environmental Meter (11 functions including Light Level measurement) EN150 ............... Environmental Meter (11 functions including UV Light measurement) EN100-TP ......... RTD Temperature Probe (PT-1000) EN100-V ........... Replacement Vane for EN100 and EN150 (2pk) Specifications subject to change without notice. Copyright 2013-2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com Rev. 7/7/15 PRODUCT DAPRODUCT DATTASHEETASHEETSpecifications Range Max Resolution Basic Accuracy Light Level (EN100 only) Foot Candles 0 to 1860Fc 0.1Fc 5% Lux 0 to 20,000Lux 1Lux 5% UVA Light - 290nm to 390nm (EN150 only) 2 2 2 W/cm 0 to 1999W/cm 1W/cm 4%FS 2 2 2 mW/cm 2 to 20mW/cm 0.01mW/cm 4%FS Air Velocity ft/min (feet per minute) 80 to 3940 ft/min 1 ft/min 3%FS m/s (meters per second) 0.4 to 20m/s 0.1m/s 3%FS km/h (kilometers per hour) 1.4 to 72km/h 0.1km/h 3%FS MPH (miles per hour) 0.9 to 45MPH 0.1MPH 3%FS knots (nautical miles per hour) 0.8 to 38.8 knots 0.1knots 3%FS Air Volume CFM 0.847 to 1,271,300CFM 0.001CFM CMM 0.024 to 36,000CMM 0.001CMM Temperature (with optional RTD probe) 14 to 158F (-10 to 70C) 0.1F/C 2.5F/1.2C Temperature (ambient) 32 to 122F (0 to 50C) 0.1F/C 2.5F/1.2C % Relative Humidity 10 to 95%RH 0.1%RH 4%RH of reading Wet Bulb 22.3 to 120.2F (-5.4 to 49.0C) 0.1F/C calculated Dew Point -13.5 to 120.2F (-25.3 to 49.0C) 0.1F/C calculated Wind Chill 15.1 to 111.6F (-9.4 to 44.2C) 0.1F/C 3.6F/2C Heat Index 32 to 212F (0 to 100C) 0.1F/C 3.6F/2C Barometric Pressure inHg 0.29 to 32.48inHg 0.01inHg 0.05inHg mmHg 7.5 to 825mmHg 0.1mmHg 1.2mmHg hPa 10 to 1100hPa 0.1hPa 2hPa Altitude feet (ft) -6000 to 30000ft 1ft 50ft meter (m) -2000 to 9000m 1m 15m Dimensions 4.7 x 1.7 x 0.7 (120 x 45 x 20mm) Vane: 1.2 (31mm) Weight 5.6oz (160g) Specifications subject to change without notice. Copyright 2013-2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com