PRC30 Multifunction Process Calibrator Precision source and measure for thermocouples (8-Types), mA, mV, and V devices Applications include: Lab and Field Calibration and V eri cation Operations of Sensors, Thermocouple Probes, Controllers, Panel meters & Testing tools. Temperature Control Process Troubleshooting Process devices calibration and simulation: Transducers, Transmitters, Indicators, Controllers, and Recorders Field test and service Bench research and development Features Palm-sized double molded housing and large dot-matrix backlit LCD Measures DC process signals High accuracy calibration function simulates precision thermocouple outputs for use in calibrating thermometers, transmitters, controllers or recorders Up to ve user adjustable calibration presets Displays output in terms of millivolts or temperature based on thermocouple tables 24V Loop Power Zero adjustment, auto zero when power on and change mode Standard banana I/O ports and mini thermocouple inputs Complete with test leads, alligator clips, Thermocouple Large battery bank for extended work cycle calibration cable with subminiature connector, universal calibration cable with subminiature terminal, 100V-240V External power adapter for continuous work cycle AC Universal Adaptor with 4 plugs, six 1.5V AA batteries, and hard carrying case Ordering PRC30 ................. Multifunction Process Calibrator PRC30-NIST ........PRC30 with Certi cate of Calibration Traceable to NIST Speci cations subject to change without notice. Copyright 2012-2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www .extech.com Rev. 4/2/14 PRODUCT DA PRODUCT DA TTASHEETASHEETSpeci cations Range Basic Accuracy DC Source Curr ent 0 to 24mA, -25% to +125% (0.01% + 1 digit) Max. Load 1000 24mA Voltage 0 to 2000mV, 0 to 20V (0.01% + 1 digit) mV/Temp -5 to 55mV (0.01% + 1 digit) Type J -58 to 1832F (-50 to 1000C) (0.05% + 2F or 1C) Type K -58 to 2498F (-50 to 1370C) (0.05% + 2F or 1C) Type T -184 to 752F (-120 to 400C) (0.05% + 2F or 1C) Type E -58 to 1382F (-50 to 750C) (0.05% + 2F or 1C) Type C, R, S 32 to 3182F (0 to 1750C) (0.05% + 2F or 1C) Type N -58 to 2372F (-50 to 1300C) (0.05% + 2F or 1C) DC Measure Curr ent 0 to 50mA, -25% to +230% (0.01% + 1 digit) Voltage 0 to 1999mV / 2 to 20V (0.01% + 1 digit) / auto range mV/Temp -10 to 60mV (0.01% + 1 digit) Type J -58 to 1832F (-50 to 1000C) (0.05% + 1.8F or 1C) Type K -58 to 2498F (-50 to 1370C) (0.05% + 1.8F or 1C) Type T -184 to 752F (-120 to 400C) (0.05% + 1.8F or 1C) Type E -58 to 1382F (-50 to 750C) (0.05% + 1.8F or 1C) Type C, R, S 32 to 3182F (0 to 1750C) (0.05% + 2F or 1C) Type N -58 to 2372F (-50 to 1300C) (0.05% + 2F or 1C) Loop Power 24V Meter Dims (LxWxH) 6.3 x 3.2 x 1.7 (159 x 80 x 44mm) Meter Wt 8.4oz (236g) - not including battery weight Speci cations subject to change without notice. Copyright 2012-2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www .extech.com