PRODUCT FAMILY DESCRIPTION INDOOR RF PASSIVES SEMI ISOLATED OUTLET : TSO-300 FEATURES >> Frequency range 5-1006 MHz >> Class A screening effectiveness >> Outstanding RF performance >> Low loss diplex filters >> 2 x Data port, IEC female and F female >> 1 x R/TV port, IEC male SPECIFICATIONS INSERTION LOSS (dB, Max.) - IN to R/TV Frequency (MHz) Typ. 5 - 65 35.0 30.0 Min. 87.5 - 862 4.5 4.8 862 - 1006 4.7 5.0 INSERTION LOSS (dB, Max.) - IN to DATA (both ports) 5 - 65 4.5 4.8 87.5 - 862 7.8 8.2 862 - 1006 8.5 9.0 RETURN LOSS (dB, Min.) All Ports 5 - 65 18.0 (1) 87.5 - 862 18.0 (1) 862 -1006 18.0 ISOLATION (dB, Min.) - R/TV to DATA 5 - 65 30.0 87.5 - 862 20.0 862 - 1006 20.0 Teleste reserves the rights to alter specifications, features, manufacturing released and even the general availability of the product at any time. Rev.: TSO 300 SPEC 150827 1 www.teleste.com SPECIFICATIONS GENERAL SPECIFICATIONS Frequency range 5 1006 MHz Nominal impedance 75 Ohm Connectors Input Cable clamp R/TV output IEC male DATA input/output F female/IEC female Dimensions 69 x 64,5 x 35 mm Weight 0,097 kg (2) Electromagnetic compatibility (dB, Min.) 5 - 300 85.0 300 - 470 80.0 470 - 950 75.0 950 - 1006 55.0 This terminal outlet has been (3) (a) Intermodulation f1 + f2 110.0 designed to fit with the typical (b) (dBc, Min.) 110.0 frames and covers. Combining (c) 110.0 the high screening with the easy frontal cable connection results Safety Isolation Inner conductor input to inner conductor output in reliable and swift installation. It features a R/TV port with (4) 2120 VDC 0.7 mA, 1 minute downstream only and two data port with both up and (4) 230 VAC RMS, 50/60 Hz 8.0 mA RMS downstream. (5) Surge immunity 1 kV, 1.2/50S Housing (material/plating) Zinc die-cast / nickel plated Steel back lid / tin plated Connectors (material/plating) Spring of F female Phosphor bronze/Nickel (6) Pin of IEC male Brass/Nickel Product approval CE EMC compatibility EN 50083-2 Notes (1) * F > 40 MHz -1.5 dB/oct (2) Class A, according to IEC 60728-2 2010, EMC (3) Two carriers (60 & 65 MHz), applied to (each)output port, 120dBV (a) No surge (b) Measured after 10 pulses 25V(1,2/500S applied to each port (c) Measured after 1 pulse 1kV (1,2/50S) applied to each port (4) According to IEC-60728-11 2007, Safety (5) Surge voltage according to IEC 61000-4-5, EMC (class 2, level 2) applied between the inner and outer conductor of each port (6) Dimensions in accordance with IEC 61169-2, Coaxial connectors of type 9,52 Teleste reserves the rights to alter specifications, features, manufacturing released and even the general availability of the product at any time. Rev.: TSO 300 SPEC 150827 2 www.teleste.com