1017 Multifunction DC V/I/R Calibrator Time Electronics Calibration, Test & Measurement DC Volts 10nV to 100V DC Current 100nA to 100mA Resistance 10m to 10k 0.005% (50ppm) accuracy 1 ppm setting resolution Noise < 2ppm (0.1 to 1Hz) Stability <5ppm/day <25ppm/yr The 1017 is a high performance portable DC calibrator for use in the field or laboratory. It is constructed in a durable, compact plastic case with a tilt stand/carry handle. Five DC voltage ranges from 10mV to 100V full scale are available, each with a 6-digit (1ppm) resolution. The DC current range is 100mA full scale with a 100nA (1ppm) resolution. Resistance from 0.01 to 10k is available 0.01 steps. The voltage, current and resistance ranges make it suitable for calibrating a wide range of transducers, from thermocouples, 4-20mA and 0-10V transmitters, to Platinum Resistance Thermometers, all in the same instrument. Power Mains or rechargeable battery. Battery operation enables good performance where earth loop and noise pick-up occurs. Stability v Temperature and Time Outstanding performance is due to the use of special computer selected reference diodes and the latest in resistor technology. The special low-thermal emf terminals reduce errors when working with microvolt signals. Digital Deviation Control Allows the output to be increased/decreased in % terms from 0 to +/-0.999%. This provides a direct read-out of error and simplifies the recording results for calibration certificates. It enables the user to immediately see if the unit under test is within specification. Time Electronics, Botany Industrial Est. Tonbridge, Kent. England. TN9 1RH. Tel: +44 (0)1732 355993 Fax: +44 (0)1732 770312 E-mail: mail timeelectronics.co.uk www.timeelectronics.com V1b 22/04/091017 Technical Specifications Voltage Ranges/Accuracy: 0 - 9.99999mV in 10nV steps, 0.02% of setting 0.005% of range 0 - 99.9999mV in 100nV steps, 0.01% of setting 0.004% of range 0 - 999.999mV in 1V steps, 0.005% of setting 0.002% of range 0 - 9.99999V in 10V steps, 0.005% of setting 0.002% of range 0 - 99.9999V in 100V steps, 0.01% of setting 0.004% of range The above accuracies are independent of thermal emfs which can be 2uV or more depending on the type of leads and connections used. Output resistance: 10mV & 100mV: 10. 1V & 10V: <150m. 100V: <1 Drive current max: 10&100mV: as 10 o/p resistance. 1V&10V: 150mA 100V: 10mA. Current Range/Accuracy: 0 - 99.9999mA in 0.1uA steps, 0.02% of setting + 0.004% of range. Drive voltage max: 10V Resistance Range/Accuracy: 0 - 9.99999k in 0.01 steps, 0.05% of setting +/- 0.003% of range. Power rating: 0.25W per resistor End resistance: less than 200m Deviation Control: 0% to 0.999% in 0.001% steps. Deviation accuracy: V&I output, 0.5%. Temperature Coefficient: <5 ppm per C Long Term Stability: <5ppm/day, <15ppm/90day, <25ppm/year Short Term Stability Noise: 10mV range: <0.2uV/sec, <0.3uV/10sec, <0.4uV/min 100mV range: <0.2uV/sec, <0.4uV/10sec, <0.6uV/min 1V range: <0.2uV/sec, <0.5uV/10sec, <1.5uV/min 10V range: <1.0uV/sec, <2.0uV/10sec, < 8.0uV/min 100V range: <40uV/sec, <100uV/10sec, <500uV/min 100mA range: <0.2uA/sec, <0.4uA/10sec, <1.0uA/min Warm-up and Settling time: Warm-up: <10 mins to full accuracy. Settling: < 0.5 secs, 100V range 5 secs. Output Connections: The output is via low thermal emf terminals (0.2uV/C). A mains earth terminal is provided for screening purposes. Output polarity can be selected by a switch on the front panel. Power Supply: The 1017 can be powered continuously from a 230V 50/60 Hz (110V to order) mains supply, or from the internal rechargeable NiCad battery pack. A front panel indicator shows the state of charge at all times. Operating temperature: 0 to 50C (32 to 120F). 15 to 25C for optimum performance. Operating Humility: 10 to 90% non-condensing 25C (77F) General Specification Dimensions: 290 x 250 x 110mm Weight: 2.4 kg (5.4 lb) Optional Extras: Calibration Certificate traceable to NPL UKAS Calibration Certificate Ordering Information Code Description 1017 Multifunction DC V/I/R Calibrator 9152 Factory (NPL Traceable) Calibration Certificate 9109 UKAS Calibration Certificate (ISO 17025) Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Time Electronics, Botany Industrial Est. Tonbridge, Kent. England. TN9 1RH. Tel: +44 (0)1732 355993 Fax: +44 (0)1732 770312 E-mail: mail timeelectronics.co.uk www.timeelectronics.com V1b 24/04/09