INSTALLATION & OPERATING INSTRUCTIONS iii Press <Program> button once - the first ON time is Programming sequence 1 To Reset Display 3. To Set Programme ON/OFF Times (after clock setting) 4. Programme Review 4. EMU17 & MEU17 Programming Instructions now set and display shows ready for the first OFF To clear programmes from memory and reset the time controller press and hold To fast review the set programmes or for quick exit to normal operating mode - Change Button Programme Button .... Programme 1 ON time Setting clock : Programme 3 ON programme time. press and hold the <Program> button. down both buttons until the display goes blank. Release buttons and display will sets Day(s), Hours used to select the : Programme 1 ON Programme 3 OFF i Press <Change> button to advance the day flag to the required day(s) settings : and Minute times clock time and the 6 fill with its complete range of characters and then clear 1 2 3 4 Programme 1 OFF Programme 4 ON : iv Now set the hrs and minutes as before. 5. Initiating Programme Mode and self cancelling ON/OFF programme which are: to show clock and day 1 symbol flashing. Programme 2 ON : Programme 4 OFF This can be initiated any time during the normal operating mode. Press override times and to review ...... : Programme 2 OFF Operating Mode You are now in the clock setting mode v Repeat steps i to iv to set the remainder of the 3 ON/OFF times as required. <Program> button and the Clock symbol, day flag, hrs and minutes symbols them once set 1 2 3 4 5 6 7 1234567 at the beginning of the programme sequence Note: Any unused ON/OFF programme should be skipped until the display on the display will flash - this is review mode. If any change to programmes is Output Status Note: Button pauses greater than 1 minute during programming will result in = 5 days (Weekdays) Mo Tu We Th Fr shows normal operating mode. Do not programme 0s into unused Easy view 24 required press <Change> button to initiate programme mode and then follow showing unit automatic return to the operating mode. Programming sequence programmes. hour digital = 2 days (Weekend) Sa Su steps 2 and 3. either ON or OFF clock/timer .... = 7 days (Everyday) Mo Tu We Th Fr Sa Su Setting clock Programme 4 ON : IMPORTANT After setting a clock time which falls within a programmed ON display 2 Setting Clock (after reset) Day indicator : = Individual days Starting with Monday through to Sunday 6. Cancelling Programmes Programme 1 ON Programme 4 OFF period, the unit will not switch ON. Use the Change button to switch unit ON. 1 = Monday : i Hour Setting - Press the <Change> button to advance Programme 1 OFF Programme 5 ON Any ON/OFF programme can be cancelled by clearing its ON and OFF time. : 7 = Sunday After this the unit will operate normally to the programmes set. the hour setting.Note: For rapid hour selections press Programme 2 ON Programme 5 OFF : Follow step 5 and when into the ON or OFF programme to be cancelled press Battery ii Once day option selected press <Program> ON Programme 2 OFF : Programme 6 ON and hold down <Change> button. 1 2 3 4 the <Change> button until the hour digits show --: ON This product has a factory fitted rechargeable battery. If the time controller is left with 4. Programme Review : Programme 3 ON Programme 6 OFF button once to select hour time - display : then press the <Program> button to clear the ...... its mains power switched off for more than 1 month the display may go blank. In To fast review the set programmes or for quick exit to normal operating mode - Programme 3 OFF Operating Mode shows hour digits and ON flashing. Press ON programme. The display will show the hour and this case switch mains on, wait 30 mins, and apply reset - see 1 before programming. press and hold the <Program> button. <Change> button to advance hour setting. ii Minute Setting - Press the <Program> button once to 1 2 3 4 5 6 7 minute digits and ON or OFF flashing. Note: Button pauses greater than 1 minute during programming will result in (Note: Monday shown as an example of days set). Programming select the minutes - display shows clock symbol (Note: Monday shown as an example of days set). automatic return to the operating mode. 5. Initiating Programme Mode 1 2 3 4 5 6 7 This is a seven day (weekly) timeswitch which has six programmes, each of which and minute digits flashing. Press the <Change> This can be initiated any time during the normal operating mode. Press 7 8 9 can be block programmed to work on all of the five weekdays, both weekend days, 10 11 12 iii Press <Program> button once to select minute time - button to advance the minutes setting. Note: For rapid Self Cancelling Override 2 Setting Clock (after reset) 1 2 3 4 <Program> button and the Clock symbol, hrs and minutes symbols on the ON or all 7seven days (24 hour operation). Programmes can also be designated to display shows minute digits and ON flashing. Press minute selection press and hold down <Change> To change the output status from ON to OFF or vice versa during normal operation display will flash - this is review mode. If any change to programmes is operate on individual days. i Day Setting - Press <Change> button to advance to the day required. <Change> button to advance minute setting. button. (Note: 16 hrs shown as example of hrs set) press the <Change> button. The output status will change and indicate override is in required press <Change> button to initiate programme mode and then follow Only two setting buttons are required, Change and Program. In normal use the Day 1 = Monday and Day 7 = Sunday. (Note: 16 hrs shown as example of hours set). operation by flashing. PanelMASTER 1 2 3 4 5 6 7 steps 2 and 3. Change button is used to switch ON or OFF, overriding the timeswitch until the ii Hour Setting - Press the <Program> button once to iii Press <Program> button once - clock is now set and next programmed OFF or ON time. During programming the Change button is select the hour - display shows clock symbol and iv Press <Program> button once - the first ON time is display shows ready for the first ON programme time 6. Cancelling Programmes used to set the hours, minutes and days. The Program button is only used when Timer Modules the hrs now set and display shows ready for the first OFF with ON and hours digits flashing. Any ON/OFF programme can be cancelled by clearing its ON and OFF time. setting or adjusting the clock time and day or the 6 programmed ON/OFF times 1 2 3 4 5 6 7 digit flashing. programme time. Follow step 5 and when into the ON or OFF programme to be cancelled press and days, although it can also be used to review the ON/OFF times and days once Without Housing 1 2 3 4 OFF Press the <Change> button to advance 3. To Set Programme ON/OFF Times the <Change> button until the hour digits show --: they have been set. Each time the Program button is pressed the display will flash the hour setting.Note: For rapid hour selections press MEU11 (24 Hour) MEU17 (7 Day) v Now set the hrs and minutes as before. ON either the days, hours or minutes in turn, starting with the clock then the first ON (after clock setting) then press the <Program> button to clear the 1 2 3 4 5 6 7 and hold down <Change> button. The day(s) selected remains the same. time and day(s), first OFF time, second ON time and day(s) etc. Wherever the programme. The display will show the hour Programme 1 ON time With Housing days, hours or minutes are flashing they may be set using the Change button. Once iii Minute Setting - Press the <Program> button once to and minute digits and ON or OFF flashing. 1 2 3 4 i Press <Change> button to advance the hour setting. set the Program button is pressed again to proceed to the next stage. select the minutes - display shows with clock symbol (Giving Panel Mount Capability) vi Repeat steps i to v to set the remainder of the 5 ON/OFF times as required. Note: 1 2 3 4 5 6 7 Self Cancelling Override and minute digits flashing. Press the <Change> Any unused ON/OFF programme should be skipped until the display shows Normal Operating Mode EMU11 (24 Hour) EMU17 (7 Day) To change the output status from ON to OFF or vice versa during normal operation button to advance the minutes setting. Note: For rapid normal operating mode. Do not programme 0s into unused programmes. In normal operation the PanelMaster will display the OFF press the <Change> button. The output status will change and indicate override is in minute selection press and hold down <Change> ii Press <Program> button once to select minute time - correct day and its time with the colon flashing. The output ON operation by flashing. button. (Note: 16 hrs shown as example of hrs set) IMPORTANT After setting a clock time which falls within a programmed ON display shows minute digits and ON flashing. Press status will be shown by either ON or OFF on the display. 1 2 3 4 5 6 7 <Change> button to advance minute setting. iv Press <Program> button once - clock is now set and period, the unit will not switch ON. Use the Change button to switch unit ON. 1 2 3 4 (Note: 16 hrs shown as example of hours set). display shows ready for the first ON programme time. 1 2 3 4 5 6 7 After this the unit will operate normally to the programmes set.Fig 2 Installation - Panel Mounting 1. Physical Arrangements & Installation Instructions 67mm 2. Specifications MEU17 & EMU17 All Types 3. EMU11 & MEU11 Programming Instructions 6 ON/OFF programmes, daily, weekly, weekend or weekday options For panel mounting (in panels up to 7.0mm thick Change Button Programme Button Connections MEU11 & EMU11 sets Hours and used to select the with the cut-out as shown in figure 2) the Easy 2 button programming Pin 1: Common. MEU 11 & MEU 17 Figure 1 4 ON/OFF programmes Minute times and clock time and the 4 Change/Override until next programme Pin 2: Positive battery charge plus relay current. Min 0.50 mA (No relay). EMU11/17 should be snapped into the bezel Easy 2 button programming self cancelling ON/OFF Pin 3: Relay connection. supplied and secured in place by the use of the 2 Rechargeable Metal Hydride battery back-up with 1000 hours reserve Change/Override until next programme override programme times Pin 4: Output & relay connection. NPN open connector. Max 10 mA, 47 V R 3.5mm Requires only an external resistor, diode and relay to switch mains No. 6 x 3/8in self-tapping screws provided as and to review them Rechargeable Metal Hydride battery back-up with 1000 hours reserve Metal A Molex 7720 4 way connector or similar is recommended. once set shown in figure 3. Temperature range 0 to 55C Requires only an external diode, resistor and relay to switch mains Hydride Easy view 24 HELPLINE MEU11 and MEU17 - Typical Usage When selecting a position for the unit it should be Battery Temperature range 0 to 55C hour digital Operation The examples in figs 6, 7 and 8 show the module driving a Shrack 48V Output Status born in mind that a clearance behind the front clock/timer 020-8450-8944 showing unit The programme button advances programme steps and the change relay with power derived from the mains. Type RP330048 or RP331048 Change Programme Operation display panel surface of 26.0mm is required over the full either ON or OFF button button (Changeover contracts). In these configurations the relay pulls in at 47V Pin Header The programme button advances programme steps and the change button then updates the item selected. Day/days of week is first to Fig 3 area of the panel cut-out. and is held at above 24V with mains voltages down to 200V. Battery be programmed followed by hours and minutes. The 6 ON/OFF button the hours and minutes which flash. Time of day is set first The unit is designed to be mounted from the front Engineering drawing can be supplied on request This product has a factory fitted rechargeable battery. If the time controller is left with EMU11 and EMU17 - Typical Usage and is updated during the programming period. Programmes 1 to 4 programmes then follow, each in the sequence day/days, hours Use No. 6 x 3/8in self- of the panel by the following procedure: its mains power switched off for more than 1 month the display may go blank. In this In this case the circuit in fig 6 can be used with a 10K, 3W resistor in place of the tapping screws to fully and minutes. If, during programming, no button is pressed over a follow. If, during programming, no button is pressed over a period EMU 11 & EMU 17 a. Insert the 2 bolts provided in the locations case switch mains on, wait 30 minutes, and apply reset - see 1 before programming. secure bezel to EMU11/17 15K, 2W resistor shown and a 1.3W zener must be connected between pins 1 of one minute then the display will revert to normal operation. In period of one minute then the display will revert to normal shown in figure 4. (fixed from rear) and 2 of the module. The circuit in fig 7 can be used with two 5K1, 1.5W Programming operation. In normal operation, pressing the change button changes normal operation, pressing the change button changes the output b. Then insert the 2 No. 4 x 5/8 in self-tapping resistors in place of the 7K5, 1W resistors shown and a 1.3W zener must be Only two setting buttons are required, Change and Program. In normal use the Change until the next programme step. the output until the next programme step. screws into the bolts and engage thread. connected between pins 1 and 2 of the module. The circuit in fig 8 can be used button is used to switch ON or OFF, overriding the timeswitch until the next c. Make connections to the unit by wires with a 330nF, X 250V ac capacitor instead of the 220nf capacitor shown and a programmed OFF or ON time. During programming the Change button is used to set 1 2 3 4 5 6 1.3W zener must be connected between pins 1 and 2 of the module. the hours and minutes. The Program button is only used when setting or adjusting the terminated in a Molex 4 way 7720 or similar In all cases the zener is 47V and its cathode is connected to module pin 2. clock time or the 4 programmed ON/OFF times, although it can also be used to review For a product brochure please contact: connector from behind the panel. the ON/OFF times once they have been set. Each time the Program button is pressed the Fig 4 Bezel d. Insert the EMU11/17 complete with bezel into Timeguard Ltd. Single Resistor PSU (MEU11 & MEU17 only) Two Resistor PSU - gives Optimum EMC Performance Capacitor PSU (MEU11 & MEU17 only) display will flash either the hours or minutes in turn, starting with the clock then the first the panel and tighten up the 2 No. 4 self- (MEU11 & MEU17 only) ON time, first OFF time, second ON time etc. Wherever the hours or minutes are Victory Park, 400 Edgware Road, Fig 8 tapping screws. The ears on the bolts will No. 4 x 5/8in self- flashing they may be set using the Change button. Once set the Program button is Bolt tapping screw London NW2 6ND rotate under the tightening action to clamp the pressed again to proceed to the next stage. Fig 6 Fig 7 unit to the panel. Tel: 020 8452 1112 Normal Operating Mode Tamper proof Bezel for panel Panel mount Slide switch allowing Surface In normal operation the PanelMaster will display the or email csc timeguard.com cover Surface Mounting mounting bolts continuous ON or mount fixing correct time with the colon flashing. The output OFF or programmed The EMU11/17 without bezel can be surface 1 2 3 4 status will be shown by either ON or OFF on the display. Contents operation mounted using the 4 securing holes as shown Designed and manufactured in the U.K. 67-057-97 (2) 1 To Reset Display 4 fixing 1 EMU11 (24 hour) or EMU17 (7 day) in figure 5. The unit can be stood off from the To clear programmes from memory and reset the time controller press and hold holes for 1 Panel mount bezel mounting surface by 10mm using the 4 spacers surface down both buttons until the display goes blank. mounting 1 Tamper proof cover if required. Screws are not provided and it Release buttons and display will fill with its complete 4 Surface mount stand offs (length 10mm) must be remembered that if used in this way range of characters and then clear to show clock and Fig 5 2 Panel mount bolts the EMU11/17 must be installed within a hour digit flashing. 1 2 3 4 2 Self-tapping screws (No. 4 x 5/8 in) for panel mount bolts housing or cubicle to prevent access to the It is possible to operate these modules from other voltages. You are now in the clock setting mode 2 Self-tapping screws (No.6 x 3/8 in) for attaching bezel to EMU11/17 mains terminations. Please contact Technical Service on 020 8450 0515 for advice. at the beginning of the programme sequence 67mm