Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to ECO-Standard High power density Low output ripples and spikes Suitable for household appliance and industrial applications For distributed power UL 1310 class II, NEC class 2 compliance UL 508 listed Universal input range 85 to 264 VAC CB Operating temperature range: Scheme UL508 UL60950-1 25C to +70C This new DIN-Rail mounting power supplies are designed for industrial and resi- Adjustable output voltage dential applications. They are lower cost than the existing TBL range, with similar Short circuit and overload protection electrical specifications. Additionally, they fully comply to the new standby power DCOK indicator LED and efficiency requirements (ECO Standard). They are intended for connect - ing as class II devices, so the safety earth connection is not required. They are mountable in flat racks due to their small dimensions in depth. Their dimensions comply to the DIN 43880 standard. Models Order Code Output Power Output Voltage* Output Current Efficiency (max.) (nom.)(adjustable) (max.) (typ.) TBLC 06-105 6 W 5.0 VDC 1.2 A 74 % TBLC 06-112 6 W 12 VDC 0.5 A 81 % TBLC 06-124 6 W 24 VDC 0.25 A 79 % TBLC 15-105 12 W 5.0 VDC 2.4 A 81 % TBLC 15-112 15 W 12 VDC 1.25 A 85 % TBLC 15-124 15 W 24 VDC 0.63 A 85 % TBLC 25-105 20 W 5.0 VDC 4.0 A 82 % TBLC 25-112 24 W 12 VDC 2.0 A 86 % 24 VDC 1.05 A 87 % TBLC 25-124 25 W TBLC 50-112 48 W 12 VDC 4.0 A 88 % TBLC 50-124 50 W 24 VDC 2.1 A 89 % TBLC 75-112 72 W 12 VDC 6.0 A 89 % TBLC 75-124 75 W 24 VDC 3.1 A 89 % TBLC 90-112 90 W 12 VDC 7.5 A 90 % TBLC 90-124 90 W 24 VDC 3.75 A 90 % TBLC Series, 6 90 W Input Specifications Input voltage nominal ranges 100 240 VAC 50/60 Hz effective ranges 85 264 VAC 47-63 Hz (below 100 VAC a derating of 2 %/V is required) Input voltage frequency 47 63 Hz No load power consumption 650 W models: < 0.3 W 7590 W models: < 0.5 W Harmonic limits EN 61000-3-2, class A Leakage current 0.25 mA max. Inrush current 650 W models: 15/30 A (115/230 VAC) 7590 W models: 25/50 A (115/230 VAC) Output Specifications Output voltage / current 5 VDC models: 5.0 5.5 VDC* 12 VDC models: 12.0 16.0 VDC* 24 VDC models: 24.0 28.0 VDC* Regulation Input variation 0.3 % max . Load variation (1090 %) 0.3 % max. Hold-up time 60 ms min. (at 230 VAC) 15 ms typ. (at 115 VAC) Start-up Start up behavior TBLC 75-112 and 90-112: 0-75 % constant current load other models: 0-100 % constant current load Start up time 1 s max. Ripple and Noise (20 MHz bandwidth) 50 mVp-p max. Current limit (continuous) 105 130 % of Iout nom., constant current Short circuit current TBLC 75-112 and 90-112: 70 90 % of Iout nom. (typ.), foldback other models: 120 200 % of I out nom Output overvoltage protection 150 % of Vout nom. (typ.) DC OK signal trigger threshold ON > 95 % of the set voltage General Specifications Operating temperature 25C to +70C derating above +55C: 2.5 %/K Storage temperature 40C to +85C Temperature coefficient 0.02 %/K Cooling convection cooling, no internal fan Pollution degree 2 Humidity (non condensing) 595 % rel. H max. Altitude during operation 4800 m max. Isolation I/O isolation 3000 VAC (4242 VDC) Class of protection safety class II Degree of protection IP 20 (IEC/EN 60529) Reliability, calculated MTBF (at 25C acc. to IEC 61709) > 1.9 Mio. h * O ut put vol t age c an be ad justed a s ind ic ated. H owever, out put power ha s to be maint ained at nominal value . This me ans the out put nominal current has to be reduced in accordance with the increase of output voltage. All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.