Industrial Power Supplies TCL Series, 24 to 240 Watt Features UL 60950UL 508C UL 60950-1 For industrial, ofcfi e and residential applications Ultracompact plastic housing Connection by spring clamp terminals or detachable screw terminal block Reliable snap-on mounting on DIN-rails Adaptor for wall mounting Universal input 85264 VAC, 50/60 Hz Models with 5, 12, 24 & 48 VDC output Output voltage adjustable Power OK signal Low ripple and noise Overload and short-circuit protection The TRACO POWER TCL series is a family of DIN-rail power supplies with an excel- lent price/performance ratio. With tightly regulated output voltage and high im- Parallel operation possible munity against electrical disturbances on the mains they provide a reliable power Worldwide safety approvals source for sensitive loads in industrial process controls, machine tools and other Redundancy module equipment exposed to a difcfi ult industrial environment. Compact size, light weight, easy snap-on mounting on DIN-rails and the choice of two connection terminal 3-year product warranty versions are other features of these power supplies. The TCL series complies with all major safety standards for Europe (EN60950-1, EN50178), North America (UL/cUL 60950, UL 508 listed) or elsewhere in the world (CB-Report). Models Order Code Input Voltage Output Power *Output Voltage Output Current Connection Ranges max. nom. max. TCL 024105 20 W 5 VDC 4.0 A TCL 024112 12 VDC 2.0 A 24 W TCL 024124 24 VDC 1.0 A 85 264 VAC TCL 060112 Universal Input 48 W 12 VDC 4.0 A 50/60 Hz TCL 060124 24 VDC 2.5 A Detachable screw 60 W TCL 060148 85 375 VDC 48 VDC 1.25 A terminal blocks TCL 120112 96 W 12 VDC 8.0 A TCL 120124 120 W 24 VDC 5.0 A 85132/187264 VAC 240 W TCL 240124 24 VDC 10.0 A TCL 024124C 24 W 24 VDC 1.0 A TCL 060112C 48 W 12 VDC 4.0 A 85 264 VAC TCL 060124C Universal Input 24 VDC 2.5 A 60 W 50/60 Hz TCL 060148C 48 VDC 1.25 A Spring clamp TCL 120112C 85 375 VDC 96 W 12 VDC 8.0 A terminals TCL 120124C 120 W 24 VDC 5.0 A * adjustable www.tracopower.com Page 1 of 6Industrial Power Supplies TCL Series 24 to 240 Watt Input Specifications Input voltage range 85264 VAC/85375 VDC TCL 240 model: 85132/187264 VAC autoselect (no DC input) Output derating at operation between 85...93 VAC/85...130 VDC 15% for TCL 060 & TCL 120 20% for TCL 024-112 & TCL 024-124 & TCL 240 30% for TCL 024-105 Input frequency 4763 Hz Harmonic limits EN 61000-3-2, Class A Input current at full load (typ.) (115 VAC / 230 VAC) TCL 024 models: 0.35 A / 0.2 A TCL 060 models: 1.2 A / 0.6 A TCL 120 models: 2.0 A / 1.0 A TCL 240 model: 3.3 A / 1.7 A Recommended circuit breaker TCL 240 model: 10 A (characteristic C or slow blow fuse) all other models: 5 A (characteristic C or slow blow fuse) Output Specifications Output voltage adjustable range 5.1 VDC model: 5.0 5.25 VDC (potentiometer on frontpanel) 12 VDC models: 12 15 VDC (12 - 16 VDC for TCL 024-112) 24 VDC models: 24 28 VDC 48 VDC models: 48 56 VDC Output regulation (10 to 90% load variation) 2.5 % (1 % for TCL 60-112) Ripple and noise (20MHz bandwidth) <50 mV pk-pk Electronic short circuit protection current limitation at 120 % typ. (constant current, automatic recovery TCL 24 models: foldback, automatic recovery) Parallel operation output current characteristic suitable for parallel operation of max. 5 units (not for TCL 240-124) Overvoltage protection, trigger point 5.1 VDC model: <6.5 VDC 12/24 VDC models: <40 VDC 48 VDC models: <60 VDC Hold-up time (115 VAC / 230 VAC) min. 15 ms / min. 125 ms TCL 240 model: min. 15 ms / min. 40 ms Power OK signal (TCL 60, 120 & 240 models only) trigger output signal point (reference to Vout) 12 VDC models: >11V 11.0 V 1.0 V / 60 mA max. 24 VDC models: >22V 22.0 V 2.0 V / 30 mA max. 48 VDC models: >44V 44.0 V 4.0 V / 15 mA max. General Specifications Temperature ranges Operating 10C to +70C max. Storage (non operating) 25C to +85C Temperature derating at 187...264 VAC or 265...375 VDC operation 1.7 %/K above +50C at 93...132 VAC or 130...187 VDC operation 1.1 %/K above +40C at 85...130 VDC operation 1.3 %/K above +30C Humidity (non condensing) 95 % rel. H max. Temperature coefficient 0.02 %/K Switching frequency 55 180 kHz depending on load (frequency modulation) Efficiency 88 % typ. Isolation voltage I/O isolation voltage (60 s) 3000 VAC www.tracopower.com Page 2 of 6