DC/DC Converter TEN 3N Series, 3 Watt Wide 2:1 input range Input filter to meet EN 55032, class A and FCC, level A without external components Extended operating temperature range 40C to +85C UL 62368-1 IEC 62368-1 Models with 1500 VDC and 3000 VDC The TEN 3N Series is a drop in replacement of the prevalent TEN 3 Series. The I/O isolation (functional insulation) up-to date design enables a cost reduction without any compromise to reliabili- ty and function. They come with an internal filter to meet EN55032 class A High reliability, MTBF >1.0 Mio. h without external components. Increased EMC immunity and extended operating 3-year product warranty temperature range of 40C to +85C make these converters an ideal solution for cost critical but demanding applications. With the standard pinning it is a drop in replacement for common 3 Watt converters in DIP24 package. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TEN 3-0510N 3.3 VDC 750 mA 77 % TEN 3-0511N 5 VDC 600 mA 80 % TEN 3-0512N 12 VDC 250 mA 82 % 4.5 - 9 VDC TEN 3-0513N 15 VDC 200 mA 82 % (5 VDC nom.) TEN 3-0515N 24 VDC 125 mA 81 % TEN 3-0521N +5 VDC 250 mA 5 VDC 250 mA 80 % TEN 3-0522N +12 VDC 125 mA 12 VDC 125 mA 82 % TEN 3-0523N +15 VDC 100 mA 15 VDC 100 mA 82 % TEN 3-1210N 3.3 VDC 750 mA 79 % TEN 3-1211N 5 VDC 600 mA 81 % TEN 3-1212N 12 VDC 250 mA 85 % 9 - 18 VDC TEN 3-1213N 15 VDC 200 mA 85 % (12 VDC nom.) TEN 3-1215N 24 VDC 125 mA 84 % TEN 3-1221N +5 VDC 250 mA 5 VDC 250 mA 80 % TEN 3-1222N +12 VDC 125 mA 12 VDC 125 mA 84 % TEN 3-1223N +15 VDC 100 mA 15 VDC 100 mA 84 % TEN 3-2410N 3.3 VDC 750 mA 79 % TEN 3-2411N 5 VDC 600 mA 81 % TEN 3-2412N 12 VDC 250 mA 85 % 18 - 36 VDC TEN 3-2413N 15 VDC 200 mA 85 % (24 VDC nom.) TEN 3-2415N 24 VDC 125 mA 84 % TEN 3-2421N +5 VDC 250 mA 5 VDC 250 mA 80 % TEN 3-2422N +12 VDC 125 mA 12 VDC 125 mA 84 % TEN 3-2423N +15 VDC 100 mA 15 VDC 100 mA 84 % TEN 3-4810N 3.3 VDC 750 mA 79 % TEN 3-4811N 5 VDC 600 mA 81 % TEN 3-4812N 12 VDC 250 mA 85 % 36 - 75 VDC TEN 3-4813N 15 VDC 200 mA 85 % (48 VDC nom.) TEN 3-4815N 24 VDC 125 mA 84 % TEN 3-4821N +5 VDC 250 mA 5 VDC 250 mA 80 % TEN 3-4822N +12 VDC 125 mA 12 VDC 125 mA 84 % TEN 3-4823N +15 VDC 100 mA 15 VDC 100 mA 84 % Options Suffix -HI - 5 Vin models with high isolation (3000 VDC), for other inputs see www.tracopower.com/overview/ten3win Page 1 / 4 www.tracopower.com December 16, 2021TEN 3N Series, 3 Watt Input Specifications Input Current - At no load 5 Vin models: 65 mA typ. 12 Vin models: 35 mA typ. 24 Vin models: 20 mA typ. 48 Vin models: 15 mA typ. - At full load 5 Vin models: 700 mA typ. 12 Vin models: 300 mA typ. 24 Vin models: 150 mA typ. 48 Vin models: 75 mA typ. Surge Voltage 5 Vin models: 11 VDC max. (1 s max.) 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 5 Vin models: 4 VDC max. 12 Vin models: 8.5 VDC max. 24 Vin models: 17.5 VDC max. 48 Vin models: 35.5 VDC max. Reflected Ripple Current 5 Vin models: 100 mAp-p typ. 12 Vin models: 30 mAp-p typ. 24 Vin models: 15 mAp-p typ. 48 Vin models: 10 mAp-p typ. Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Short Circuit Input Power 2 W max. Output Specifications Voltage Set Accuracy 2% max. Regulation - Input Variation (Vmin - Vmax) single output models: 1% max. dual output models: 1% max. - Load Variation (0 - 100%) single output models: 1% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Voltage Balance dual output models: 2% max. (symmetrical load) Ripple and Noise - 20 MHz Bandwidth 70 mVp-p max. Capacitive Load - single output 3.3 Vout models: 680 F max. 5 Vout models: 470 F max. 12 Vout models: 330 F max. 15 Vout models: 220 F max. 24 Vout models: 100 F max. - dual output 5 / -5 Vout models: 220 / 220 F max. 12 / -12 Vout models: 150 / 150 F max. 100 / 100 F max. 15 / -15 Vout models: Minimum Load Not required Temperature Coefficient 0.02 %/K max. Short Circuit Protection Continuous, Automatic recovery Overload Protection Foldback Mode Output Current Limitation 120% min. of Iout max. 150% typ. of Iout max. Transient Response - Response Deviation 3% typ. / 5% max. (75% to 100% Load Step) - Response Time 300 s typ. / 500 s max. (75% to 100% Load Step) All specifications valid at nominal voltage, resistive full load and +25C after warm-up time, unless otherwise stated. Page 2 / 4 www.tracopower.com December 16, 2021