DC/DC Converters TEN 40 Series, 40 Watt Features High power density: 40 W in a 51x51x10mm (2x2x0.4) package Wide 2:1 input voltage range Models with single-, dual- and triple output Models with 2 independently regulated 3.3 and 5.0 VDC outputs Extended operating temperature range: 40C to +75C The TEN 40 series is a family of high performance 40W dc-dc converter modules Over temperature protection featuring 30 standard models with wide 2:1 input voltage ranges in a compact low Under voltage lockout prole cfi ase with industry-standard footprint. A very high efcfi iency allows an operat - ing temperature range of 40C to +75C. Built-in filters for both input and output Remote On/Off minimizes the need for external filtering. Further standard features include remote Shielded metal case with insulated On/Off, output voltage trimming, over voltage protection, under voltage lockout and baseplate short circuit protection. Optional heatsink Typical applications for these products are battery operated equipment and distributed Lead free design - RoHS compliant power architectures in communication and industrial electronics, everywhere where 3-years product warranty isolated, tightly regulated voltages are required and space is limited on the PCB. Models Order code Input voltage range Output 1 Output 2 Output 3 Efficiency typ.. TEN 40-1210 3.3 VDC / 8.0 A 86 % TEN 40-1211 5 VDC / 8.0 A 86 % TEN 40-1212 12 VDC / 3.3 A 86 % TEN 40-1220 *3.3 VDC / 8.0 A *5 VDC / 8.0 A 85 % TEN 40-1222 9 18 VDC +12 VDC / 1.8 A 12 VDC / 1.8 A 85 % TEN 40-1223 (nominal 12 VDC) +15 VDC / 1.4 A 15 VDC / 1.4 A 85 % TEN 40-1233 3.3 VDC / 6.0 A +12 VDC / 0.4 A 12 VDC / 0.4 A 84 % TEN 40-1234 3.3 VDC / 6.0 A +15 VDC / 0.3 A 15 VDC / 0.3 A 84 % TEN 40-1231 5 VDC / 6.0 A +12 VDC / 0.4 A 12 VDC / 0.4 A 86 % TEN 40-1232 5 VDC / 6.0 A +15 VDC / 0.3 A 15 VDC / 0.3 A 86 % TEN 40-2410 3.3 VDC / 8.0 A 87 % TEN 40-2411 5 VDC / 8.0 A 89 % TEN 40-2412 12 VDC / 3.3 A 88 % TEN 40-2420 *3.3 VDC / 8.0 A *5 VDC / 8.0 A 86 % TEN 40-2422 18 36 VDC +12 VDC / 1.8 A 12 VDC / 1.8 A 87 % (nominal 24 VDC) TEN 40-2423 +15 VDC / 1.4 A 15 VDC / 1.4 A 87 % TEN 40-2433 3.3 VDC / 6.0 A +12 VDC / 0.4 A 12 VDC / 0.4 A 85 % TEN 40-2434 3.3 VDC / 6.0 A +15 VDC / 0.3 A 15 VDC / 0.3 A 85 % TEN 40-2431 5 VDC / 6.0 A +12 VDC / 0.4 A 12 VDC / 0.4 A 87 % TEN 40-2432 5 VDC / 6.0 A +15 VDC / 0.3 A 15 VDC / 0.3 A 87 % TEN 40-4810 3.3 VDC / 8.0 A 88 % TEN 40-4811 5 VDC / 8.0 A 90 % TEN 40-4812 12 VDC / 3.3 A 89 % TEN 40-4820 *3.3 VDC / 8.0 A *5 VDC / 8.0 A 88 % TEN 40-4822 36 75 VDC +12 VDC / 1.8 A 12 VDC / 1.8 A 87 % TEN 40-4823 (nominal 48 VDC) +15 VDC / 1.4 A 15 VDC / 1.4 A 87 % TEN 40-4833 3.3 VDC / 6.0 A +12 VDC / 0.4 A 12 VDC / 0.4 A 86 % TEN 40-4834 3.3 VDC / 6.0 A +15 VDC / 0.3 A 15 VDC / 0.3 A 86 % TEN 40-4831 5 VDC / 6.0 A +12 VDC / 0.4 A 12 VDC / 0.4 A 88 % TEN 40-4832 5 VDC / 6.0 A +15 VDC / 0.3 A 15 VDC / 0.3 A 88 % Note - Multi output models have a common ground. * dynamic current allocation, max. 8A total output current for both outputs together DC/DC Converters TEN 40 40 Watt Input Specifications Input current at no load 12 V models: 200 mA typ. 24 V models: 100 mA typ. 48 V models: 50 mA typ. Input current at full load 3.3 V single output models: 2680 / 1325 / 655 mA typ. (nominal input 12/24/48 Vin) 5.0 / 12 V single output models: 4065 / 2000 / 1000 mA typ. 3.3 & 5 V dual output models: 3415 / 1685 / 825 mA typ. 12 / 15 V dual output models: 4400 / 2100 / 1050 mA typ. 3.3 V triple output models: 3000 / 1500 / 750 mA typ. 5.0 V triple output models: 4000 / 1990 / 980 mA typ. Input voltage variation (dv/dt) 5 V/ms max. (complies to ETS300 132 part 4.4) Start-up voltage / under voltage lockout 12 Vin models: 9 VDC / 8 VDC (typ.) 24 Vin models: 17.8 VDC / 15.8 VDC (typ.) 48 Vin models: 36 VDC / 33 VDC (typ.) Surge voltage (100 msec. max.) 12 / 24 / 48 Vin models: 25/50/100 V max. Conducted noise (input) EN 55022 level A, FCC part 15, level A (with external components) Please refer to Application note: www.tracopower.com/overview/ten40 ESD (input) EN 61000-4-2, perf. criteria B Fast transient (input) EN 61000-4-4, perf. criteria B Surge (input) EN 61000-4-5, perf. criteria B Output Specifications Voltage set accuracy 1 % (5 % for auxilary outputs) Output voltage adjustment 10 % (only for single output models and symetric dual output models) Please refer to Application note: www.tracopower.com/overview/ten40 Regulation Input variation Vin min. to Vin max. single output models: 0.5 % max. dual output models: 1 % max. triple output models (main/auxiliary): 1 % max. / 5 % max. Load variation 10 100 % single output models: 0.5 % max. dual output models: 1 % max. triple output models (main/auxiliary): 2 % max. / 5 % max. Load cross variation 25 % /100 % Dual output models: 5 % max. triple output models (main/auxiliary): 1 % max. / 5 % max. Temperature coefficient 0.02 %/K max. Ripple and noise (20 MHz Bandwidth) 3.3 V & 5 V outputs: 50 mVpk-pk max. dual outputs: 150 mVpk-pk max. all other outputs: 75 mVpk-pk max. Start up time (nominal Vin and constant resistive load) 25 ms typ. Transient response time (25% load change) 300 s typ. Short circuit protection indefinite (automatic recovery) Over load protection 150 % of Iout max typ. foldback Thermal shutdown at 115C typ. Over voltage protection 3.3 V output: 3.9 V 5 V output: 6.2 V 12 V output: 15 V 15 V output: 18 V All specicfi ations valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.