DC/DC Converter TEP 100 Series, 100 Watt Rugged, compact metal case Screw terminal adaptor available for easy connection Wide 2:1 input voltage range Full load operation up to 60C with convection cooling UL 62368-1 IEC 62368-1 Soft start The TEP 100 Series is a family of isolated high performance DC/DC converter Under voltage lock-out circuit modules with ultra-wide 2:1 input voltage ranges which come in a rugged, sealed metal case. These converters are suitable for a wide range of applica- Reverse input voltage protection tions. For easy connection there is also an unique adaptor available with screw Input protection filter terminals. A very high efficiency allows an operating temperature up to +60C with natural convection cooling without power derating. Further features in- 3-year product warranty clude output voltage trimming, Remote On/Off and under voltage lockout. The very wide input voltage range make these converters also an interesting solu- tion for battery operated systems. Models Order Code Input Voltage Output Voltage Output Current Efficiency Range nom. max. typ. TEP 100-1210 3.3 VDC 25 000 mA 90 % TEP 100-1211 5 VDC 20 000 mA 91 % TEP 100-1212 12 VDC 8 400 mA 91 % 9 - 18 VDC TEP 100-1213 15 VDC 6 700 mA 91 % (12 VDC nom.) TEP 100-1215 24 VDC 4 200 mA 90 % TEP 100-1216 28 VDC 3 600 mA 90 % 48 VDC 2 100 mA 90 % TEP 100-1218 TEP 100-2410 3.3 VDC 25 000 mA 91 % TEP 100-2411 5 VDC 20 000 mA 93 % TEP 100-2412 12 VDC 8 400 mA 93 % 18 - 36 VDC TEP 100-2413 15 VDC 6 700 mA 93 % (24 VDC nom.) TEP 100-2415 24 VDC 4 200 mA 92 % TEP 100-2416 28 VDC 3 600 mA 92 % TEP 100-2418 48 VDC 2 100 mA 92 % TEP 100-4810 3.3 VDC 25 000 mA 91 % TEP 100-4811 5 VDC 20 000 mA 93 % TEP 100-4812 12 VDC 8 400 mA 93 % 36 - 75 VDC TEP 100-4813 15 VDC 6 700 mA 93 % (48 VDC nom.) TEP 100-4815 24 VDC 4 200 mA 92 % TEP 100-4816 28 VDC 3 600 mA 92 % TEP 100-4818 48 VDC 2 100 mA 92 % Page 1 / 5 www.tracopower.com June 17, 2021TEP 100 Series, 100 Watt Options Suffix -CM - Chassis mount models without filter: www.tracopower.com/products/tep100cm.pdf - Chassis mount models with filter to meet EN 55032 class A: www.tracopower.com/products/tep100cmf.pdf Suffix -CMF TEP-HS1 - Optional Heat Sink: www.tracopower.com/products/tep-hs1.pdf on demand (backorder with MOQ - Inverse Remote On/Off function (passive = off) non stocking item) Input Specifications Input Current - At no load 12 Vin models: 130 mA typ. 24 Vin models: 120 mA typ. 48 Vin models: 70 mA typ. - At full load 12 Vin models: 9 400 mA max. 24 Vin models: 4 600 mA max. 48 Vin models: 2 300 mA max. Surge Voltage 12 Vin models: 36 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 12 Vin models: 7.5 VDC typ. 16 VDC typ. 24 Vin models: 48 Vin models: 34 VDC typ. Recommended Input Fuse 12 Vin models: 20 000 mA (fast acting) 24 Vin models: 10 000 mA (fast acting) 48 Vin models: 5 000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Reverse Voltage Protection Parallel diode (external input fuse required) Input Filter Internal Pi-Type Output Specifications Output Voltage Adjustment 20% to +10% (By external trim resistor) See application note: www.tracopower.com/overview/tep100 Output power must not exceed rated power Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) 0.1% max. - Load Variation (0 - 100%) 0.1% max. Ripple and Noise 3.3 Vout models: 75 mVp-p max. (w/ 4.7 F X7R) (20 MHz Bandwidth) 5 Vout models: 75 mVp-p max. (w/ 4.7 F X7R) 12 Vout models: 100 mVp-p max. (w/ 4.7 F X7R) 15 Vout models: 100 mVp-p max. (w/ 4.7 F X7R) 24 Vout models: 200 mVp-p max. (w/ 4.7 F X7R) 28 Vout models: 200 mVp-p max. (w/ 4.7 F X7R) 48 Vout models: 300 mVp-p max. (w/ 2.2 F X7R) Capacitive Load 3.3 Vout models: 75 700 F max. 5 Vout models: 40 000 F max. 12 Vout models: 7 000 F max. 15 Vout models: 4 460 F max. 24 Vout models: 1 750 F max. 1 280 F max. 28 Vout models: 48 Vout models: 430 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Start-up Time 25 ms typ. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 110 - 140% of Iout max. All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 5 www.tracopower.com June 17, 2021