AC/DC Medical Power Supply TMM 40 Series, 40 Watt Fully encapsulated low profile plastic casing in PCB version 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition IT and industrial safety according to IEC/EN/UL 60950-1 Ready to meet ErP directive <0.3 W no load power consumption 40C start-up temperature Safety class II prepared Protection against over-temperature, overload and short circuit UL 508 ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 3-year product warranty The TMM 40 Series of fully encapsulated 40 Watt AC/DC power supply mod- ules feature a reinforced/double I/O isolation system according to latest med- ical safety standards 60601-3 3rd edition for 2 x MOPP (Means Of Patient Pro- tection). The high efficiency and the use of highest grade components make the units suitable for an operating temperature range of 40C to +60C while it goes up to 75C with 50% load derating. EMI/EMC characteristics and the safety ap- proval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in indus- trial an commercial environment. Models Order Code Output Output 1 Output 2 Efficiency Power Vnom Imax Vnom Imax TMM 40105 5 VDC 8 000 mA 81 % TMM 40112 12 VDC 3 330 mA 84 % TMM 40115 15 VDC 2 660 mA 85 % 40 W TMM 40124 24 VDC 1 660 mA 84 % TMM 40212 +12 VDC 1 660 mA 12 VDC 1 660 mA 84 % TMM 40215 +15 VDC 1 330 mA 15 VDC 1 330 mA 85 % Page 1 / 4 www.tracopower.com January 19, 2021TMM 40 Series, 40 Watt Input Specifications Input Voltage - AC Range 85 - 264 VAC (Full Range) - DC Range 120 - 370 VDC (Designed for, no certification) Input Frequency 47 - 63 Hz (designed to meet: 47 - 440 Hz) Input Current - Full Load & Vin = 230 VAC 5 VDC model: 430 mA max. 12 VDC model: 415 mA max. 15 VDC model: 410 mA max. 24 VDC model: 415 mA max. 12 / -12 VDC model: 415 mA max. 15 / -15 VDC model: 410 mA max. - Full Load & Vin = 115 VAC 5 VDC model: 720 mA max. 12 VDC model: 690 mA max. 15 VDC model: 680 mA max. 24 VDC model: 690 mA max. 12 / -12 VDC model: 690 mA max. 15 / -15 VDC model: 680 mA max. Power Consumption - At no load 300 mW max. (Ready to meet ErP directive) Input Inrush Current - At 230 VAC 60 A max. - At 115 VAC 30 A max. Input Protection T 2 A / 250 VAC (Internal Fuse in L & N) Recommended Input Fuse 3000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Output Specifications Voltage Set Accuracy 2% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.5% max. - Load Variation (0 - 100%) single output models: 1% max. dual output models: 2% max. (Output 1) 2% max. (Output 2) Ripple and Noise - single output 5 VDC model: 90 mVp-p max. (20 MHz Bandwidth) 155 mVp-p max. 12 VDC model: 15 VDC model: 195 mVp-p max. 24 VDC model: 310 mVp-p max. - dual output 12 / -12 VDC model: 155 / 155 mVp-p max. 15 / -15 VDC model: 195 / 195 mVp-p max. 80 mVp-p typ. - single output 5 VDC model: 12 VDC model: 120 mVp-p typ. 15 VDC model: 150 mVp-p typ. 24 VDC model: 240 mVp-p typ. - dual output 12 / -12 VDC model: 120 / 120 mVp-p typ. 15 / -15 VDC model: 150 / 150 mVp-p typ. Capacitive Load - single output 5 VDC model: 8 000 F max. 12 VDC model: 3 900 F max. 15 VDC model: 3 900 F max. 24 VDC model: 680 F max. 1 500 / 1 500 F max. - dual output 12 / -12 VDC model: 15 / -15 VDC model: 1 000 / 1 000 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Hold-up Time - At 230 VAC 50 ms min. - At 115 VAC 10 ms min. Start-up Overshoot Voltage 5% max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 105% min. of Iout max. All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com January 19, 2021