AC/DC Medical Power Supply TPP 40A Series, 40 Watt Open frame power supply with pin connector Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP Low leakage current <75 A rated for BF applications Risk management process according to ISO 14971 incl. risk management file Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3 EMC compliance to IEC 60601-1-2 ed. 4 Protection class l and ll prepared Operating up to 5000 m altitude ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 Ready to meet ErP directive, <0.15 W no load power consumption The TPP 40A Series of 40 Watt AC/DC power supplies feature a reinforced double I/O isolation system according to latest medical safety standards IEC/- 5-year product warranty EN/ES 60601-1 3rd edition for 2 x MOPP up to 5000 m altitude. The leakage current is below 75 A what makes the units suitable for BF (body floating) ap- plications. The excellent efficiency of up to 92% allows a high power density for the stan- dard 2.0 x 3.0 packaging format. The full load operating temperature range is 40C to +70C while it goes up to 85C with 50% load derating. The EMC characteristic complies to IEC 60601-1-2 ed.4 and is dedicated for applica- tions in industrial and domestic fields. High reliability is provided by use of in- dustrial quality grade components and an excellent thermal management. It makes the products an ideal solution for medical devices and for demanding safety and space critical applications. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TPP 40-105A-J 5 VDC (4.5 - 5.5 VDC) 8 000 mA 90 % TPP 40-112A-J 12 VDC (10.8 - 13.2 VDC) 3 340 mA 92 % 40 W TPP 40-124A-J 24 VDC (21.6 - 26.4 VDC) 1 670 mA 92 % 48 VDC (43.2 - 52.8 VDC) 840 mA 93 % TPP 40-148A-J Note - Other output models are available on request. Page 1 / 4 www.tracopower.com November 2, 2021TPP 40A Series, 40 Watt Input Specifications Input Voltage - AC Range 85 - 264 VAC (Full Range) - DC Range 120 - 370 VDC (Designed for, no certification) Input Frequency 47 - 63 Hz Input Current - Full Load & Vin = 230 VAC 500 mA max. - Full Load & Vin = 115 VAC 1 000 mA max. Power Consumption - At no load 150 mW max. (Ready to meet ErP directive) Input Inrush Current - At 230 VAC 60 A max. Input Protection T 3.15 A / 250 VAC (Internal Fuse in L & N) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Output Specifications Output Voltage Adjustment 10% (By trim potentiometer) Output power must not exceed rated power Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) 0.2% max. - Load Variation (0 - 100%) 0.7% max. (5 VDC model) 0.5% max. (other output models) Ripple and Noise 5 VDC model: 75 mVp-p typ. (w/ 10 F X7R) (20 MHz Bandwidth) 12 VDC model: 75 mVp-p typ. (w/ 10 F X7R) 24 VDC model: 75 mVp-p typ. (w/ 1 F X7R) 48 VDC model: 150 mVp-p typ. (w/ 0.1 F X7R) Capacitive Load 5 VDC model: 16 000 F max. 12 VDC model: 2 785 F max. 24 VDC model: 700 F max. 48 VDC model: 175 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Hold-up Time - At 115 VAC 25 ms min. Start-up Time - At 230 VAC 1 000 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 115 - 180% of Iout max. 145% typ. of Iout max. Overvoltage Protection 125 - 140% of Vout nom. Transient Response - Response Deviation 3% max. (50% to 75% Load Step) - Response Time 600 s typ. (50% to 75% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 2 x MOPP (Means Of Patient Protection) - Certification Documents www.tracopower.com/overview/tpp40a Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II All specifications valid at nominal voltage, resistive full load and +25C after warm-up time, unless otherwise stated. Page 2 / 4 www.tracopower.com November 2, 2021