AC/DC Medical Power Supply TPP 40 Series, 40 Watt Enclosed power supply with screw terminal connection Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP Low leakage current <75 A rated for BF applications Risk management process according to ISO 14971 incl. risk management file Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3 EMC compliance to IEC 60601-1-2 ed. 4 Protection class l and ll prepared Operating up to 5000 m altitude ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 Ready to meet ErP directive, <0.15 W no load power consumption The TPP 40 Series of 40 Watt AC/DC power supplies feature a reinforced dou- ble I/O isolation system according to latest medical safety standards IEC/EN/- 5-year product warranty ES 60601-1 3rd edition for 2 x MOPP up to 5000 m altitude. The leakage cur- rent is below 75 A what makes the units suitable for BF (body floating) appli- cations. The excellent efficiency of up to 92% allows a high power density for the stan- dard 2.38 x 3.53 packaging format. The full load operating temperature range is 40C to +70C while it goes up to 85C with 50% load derating. The EMC characteristic complies to IEC 60601-1-2 ed.4 and is dedicated for appli- cations in industrial and domestic fields. High reliability is provided by use of in- dustrial quality grade components and an excellent thermal management. It makes the products an ideal solution for medical devices and for demanding safety and space critical applications. Models Order Code Output Output 1 Output 2 Output 3 Efficiency Power Vnom Imax Vnom Imax Vnom Imax typ. TPP 40-105 5 VDC 8 000 mA 90 % TPP 40-112 12 VDC 3 340 mA 92 % TPP 40-115 15 VDC 2 670 mA 92 % TPP 40-124 24 VDC 1 670 mA 92 % TPP 40-221 +12 VDC 3 340 mA +5 VDC 6 000 mA 89 % 40 W TPP 40-231 +15 VDC 2 670 mA +5 VDC 6 000 mA 89 % TPP 40-251 +24 VDC 1 670 mA +5 VDC 6 000 mA 86 % TPP 40-321M2 +12 VDC 3 340 mA +5 VDC 6 000 mA 12 VDC 500 mA 88 % TPP 40-331M3 +15 VDC 2 670 mA +5 VDC 6 000 mA 15 VDC 500 mA 88 % TPP 40-3512 +24 VDC 1 670 mA +5 VDC 6 000 mA +12 VDC 500 mA 86 % Note - Total output power must not exceed 40 W. - Other output models are available on request. Page 1 / 5 www.tracopower.com November 2, 2021TPP 40 Series, 40 Watt Input Specifications Input Voltage - AC Range 85 - 264 VAC (Full Range) - DC Range 120 - 370 VDC (Designed for, no certification) Input Frequency 47 - 63 Hz single output models: Input Current - Full Load & Vin = 230 VAC 500 mA max. dual output models: 550 mA max. tripleoutput models: 550 mA max. single output models: - Full Load & Vin = 115 VAC 1 000 mA max. dual output models: 1 050 mA max. triple output models: 1 050 mA max. Power Consumption - At no load 150 mW max. (Ready to meet ErP directive) Input Inrush Current - At 230 VAC 60 A max. Input Protection T 3.15 A / 250 VAC (Internal Fuse in L & N) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Output Specifications Output Voltage Adjustment 10% (only Output 1) (By trim potentiometer) Output power must not exceed rated power Voltage Set Accuracy 1% max. (Output 1) 2% max. (Output 2 and 3) Regulation - Input Variation (Vmin - Vmax) single output models: 0.2% max. dual output models: 0.2% max. triple output models: 0.2% max. - Load Variation (0 - 100%) single output models: 0.7% max. (5 VDC model) 0.5% max. (other output models) dual output models: 0.5% max. (Output 1) 1.5% max. (Output 2) triple output models: 0.5% max. (Output 1) 1.5% max. (Output 2) 0.7% max. (Output 3) - Cross Regulation dual output models: 1.5% max. (25% / 100% asym. load) triple output models: 1.5% max. Ripple and Noise - single output 5 VDC model: 75 mVp-p typ. (w/ 10 F X7R) (20 MHz Bandwidth) 12 VDC model: 75 mVp-p typ. (w/ 10 F X7R) 15 VDC model: 75 mVp-p typ. (w/ 10 F X7R) 24 VDC model: 75 mVp-p typ. (w/ 1 F X7R) - dual output 12 / 5 VDC model: 120 / 100 mVp-p typ. (w/ 10 F X7R) 15 / 5 VDC model: 150 / 100 mVp-p typ. (w/ 10 F X7R) 24 / 5 VDC model: 240 / 100 mVp-p typ. (w/ 10 F X7R) - triple output 12 / 5 / -12 VDC model: 120 / 100 / 120 mVp-p typ. (w/ 10 F X7R) 15 / 5 / -15 VDC model: 150 / 100 / 150 mVp-p typ. (w/ 10 F X7R) 24 / 5 / 12 VDC model: 240 / 100 / 120 mVp-p typ. (w/ 10 F X7R) Capacitive Load - single output 5 VDC model: 16 000 F max. 12 VDC model: 2 785 F max. 15 VDC model: 1 780 F max. 24 VDC model: 700 F max. - dual output 12 / 5 VDC model: 1 750 / 2 000 F max. 15 / 5 VDC model: 1 670 / 2 000 F max. 24 / 5 VDC model: 440 / 2 000 F max. - triple output 12 / 5 / -12 VDC model: 1 750 / 2 000 / 420 F max. 15 / 5 / -15 VDC model: 1 670 / 2 000 / 420 F max. 24 / 5 / 12 VDC model: 440 / 2 000 / 420 F max. Minimum Load Not required (0.5 W for Vout1 and Vout2 if Vout3 = Full Load) All specifications valid at nominal voltage, resistive full load and +25C after warm-up time, unless otherwise stated. Page 2 / 5 www.tracopower.com November 2, 2021