DC/DC Converter TRI 6 Series, 6 Watt Reinforced I/O-isolation 5000 VAC rated for 1000 VAC working voltage Ultra-high isolation peak voltage 9000 VDC (1s) Common Mode Transient Immunity (dv/dt) 15 kV/s Operating temperature range -40 to UL 62368-1 IEC 62368-1 +85C The new TRI 6 is a high isolation, regulated 6 Watt DC/DC converter series Low no-load power consumption 120 which comes in a compact DIP-24 package. The core characteristic of the TRI 240 mW 6 series is a sophisticated reinforced isolation system which is able to with- stand high test voltages (9000 VDC for 1s and 5000 VAC for 60s) and working Internal EN 55032 class A filter voltages (1000 VACrms). Complementing this isolation characteristic is a high Common Mode Transient Immunity of 15 kV/s. The new design allows to fully High efficiency up to 89% integrate an EN 55032 class A filter and greatly reduces the no-load power 2:1 input voltage range: 9-18, 18-36, consumption. High efficiencies up to 89% allow safe operation from 40C to 36-75 VDC +85C without derating. All models have a wide 2:1 input voltage range and precisely regulated, isolated output voltages. With the latest IT safety certifica- Protection against overload, overvoltage tions (IEC/EN/UL 62368-1) the TRI 6 series is the perfect choice for many de- and short circuit manding applications in the industrial, transportation and instrumentation sec- 3-year product warranty tors. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TRI 6-1211 5 VDC 1 200 mA 83 % TRI 6-1212 12 VDC 500 mA 86 % TRI 6-1213 9 - 18 VDC 15 VDC 400 mA 86 % (12 VDC nom.) TRI 6-1215 24 VDC 250 mA 86 % TRI 6-1222 +12 VDC 250 mA 12 VDC 250 mA 87 % TRI 6-1223 +15 VDC 200 mA 15 VDC 200 mA 87 % TRI 6-2411 5 VDC 1 200 mA 83 % TRI 6-2412 12 VDC 500 mA 86 % 18 - 36 VDC 15 VDC 400 mA 87 % TRI 6-2413 (24 VDC nom.) TRI 6-2415 24 VDC 250 mA 85 % TRI 6-2422 +12 VDC 250 mA 12 VDC 250 mA 86 % TRI 6-2423 +15 VDC 200 mA 15 VDC 200 mA 87 % TRI 6-4811 5 VDC 1 200 mA 83 % TRI 6-4812 12 VDC 500 mA 86 % TRI 6-4813 36 - 75 VDC 15 VDC 400 mA 89 % (48 VDC nom.) TRI 6-4815 24 VDC 250 mA 86 % +12 VDC 250 mA 12 VDC 250 mA 87 % TRI 6-4822 TRI 6-4823 +15 VDC 200 mA 15 VDC 200 mA 88 % Page 1 / 4 www.tracopower.com January 18, 2021TRI 6 Series, 6 Watt Input Specifications Input Current - At no load 12 Vin models: 10 mA typ. 24 Vin models: 8 mA typ. 48 Vin models: 5 mA typ. - At full load 12 Vin models: 583 mA typ. 24 Vin models: 291 mA typ. 48 Vin models: 144 mA typ. Surge Voltage 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 12 Vin models: 8 VDC typ. 24 Vin models: 16 VDC typ. 48 Vin models: 34 VDC typ. Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Output Specifications Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.5% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Voltage Balance dual output models: 2% max. (symmetrical load) - Cross Regulation dual output models: 5% max. (25% / 100% asym. load) Ripple and Noise - 20 MHz Bandwidth 70 mVp-p max. (w/ 1 F MLCC) Capacitive Load - single output 5 Vout models: 1 500 F max. 12 Vout models: 260 F max. 15 Vout models: 210 F max. 24 Vout models: 75 F max. - dual output 12 / -12 Vout models: 150 / 150 F max. 15 / -15 Vout models: 110 / 110 F max. Minimum Load Not required Temperature Coefficient 0.01 %/K max. Start-up Time 30 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 150% typ. of Iout max. Transient Response - Response Deviation 5% max. (75% to 100% Load Step) - Response Time 300 s typ. (75% to 100% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 www.tracopower.com/overview/tri6 - Certification Documents Pollution Degree PD 2 Over Voltage Category OVC II All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com January 18, 2021