DC/DC Converter TRN 3 Series, 3 Watt Compact SIP package 11,9 x 7,7 x 11,0 mm Fully regulated outputs Input Voltage range 4.5-13.2, 9-18, 18-36, 36-75 VDC I/O-isolation 1600 VDC The TRN 3 Series comprises 3 Watt fully regulated, high performance DC/DC Operating temperature range converters. They come in a compact cubical package of only 1.00 cm. Full 40C to +85C load operation is reliable up tp 65C environment temperature. With 1600 VDC I/O isolation voltage, and short current protection they cover a wide range Short circuit protection of application when space is limited. The input of the converters is designed for Designed to meet UL 62368-1 (UL a wide voltage range (2:1) and minimum load is not required. The functional 60950-1) I/O-isolation system is designed to meet IEC/EN 62368-1 with a test voltage (60 s) of 1600 VDC. 3-year product warranty Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TRN 3-0510 3.3 VDC 700 mA 75 % TRN 3-0511 5 VDC 600 mA 78 % TRN 3-0512 12 VDC 250 mA 82 % 4.5 - 13.2 VDC TRN 3-0513 15 VDC 200 mA 80 % (9 VDC nom.) TRN 3-0515 24 VDC 125 mA 80 % TRN 3-0521 +5 VDC 300 mA 5 VDC 300 mA 77 % TRN 3-0522 +12 VDC 125 mA 12 VDC 125 mA 80 % TRN 3-0523 +15 VDC 100 mA 15 VDC 100 mA 80 % TRN 3-1210 3.3 VDC 700 mA 76 % TRN 3-1211 5 VDC 600 mA 79 % TRN 3-1212 12 VDC 250 mA 84 % 9 - 18 VDC TRN 3-1213 15 VDC 200 mA 83 % (12 VDC nom.) TRN 3-1215 24 VDC 125 mA 82 % TRN 3-1221 +5 VDC 300 mA 5 VDC 300 mA 78 % TRN 3-1222 +12 VDC 125 mA 12 VDC 125 mA 82 % +15 VDC 100 mA 15 VDC 100 mA 81 % TRN 3-1223 TRN 3-2410 3.3 VDC 700 mA 76 % TRN 3-2411 5 VDC 600 mA 78 % TRN 3-2412 12 VDC 250 mA 84 % 18 - 36 VDC TRN 3-2413 15 VDC 200 mA 84 % (24 VDC nom.) TRN 3-2415 24 VDC 125 mA 83 % TRN 3-2421 +5 VDC 300 mA 5 VDC 300 mA 79 % TRN 3-2422 +12 VDC 125 mA 12 VDC 125 mA 83 % TRN 3-2423 +15 VDC 100 mA 15 VDC 100 mA 82 % TRN 3-4810 3.3 VDC 700 mA 75 % TRN 3-4811 5 VDC 600 mA 79 % TRN 3-4812 12 VDC 250 mA 83 % 36 - 75 VDC TRN 3-4813 15 VDC 200 mA 83 % (48 VDC nom.) TRN 3-4815 24 VDC 125 mA 82 % TRN 3-4821 +5 VDC 300 mA 5 VDC 300 mA 77 % TRN 3-4822 +12 VDC 125 mA 12 VDC 125 mA 82 % TRN 3-4823 +15 VDC 100 mA 15 VDC 100 mA 80 % Page 1 / 4 www.tracopower.com December 10, 2021TRN 3 Series, 3 Watt Input Specifications Input Current - At no load 9 Vin models: 75 mA typ. 12 Vin models: 40 mA typ. 24 Vin models: 20 mA typ. 48 Vin models: 12 mA typ. Surge Voltage 9 Vin models: 15 VDC max. (1 s max.) 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Reflected Ripple Current 9 Vin models: 100 mAp-p typ. 12 Vin models: 75 mAp-p typ. 24 Vin models: 75 mAp-p typ. 48 Vin models: 50 mAp-p typ. Recommended Input Fuse 9 Vin models: 1 600 mA (slow blow) 12 Vin models: 800 mA (slow blow) 24 Vin models: 500 mA (slow blow) 48 Vin models: 315 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Capacitor Output Specifications Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.2% max. dual output models: 0.2% max. - Load Variation (0 - 100%) single output models: 1% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Cross Regulation dual output models: 5% max. (25% / 100% asym. load) Ripple and Noise - 20 MHz Bandwidth 50 mVp-p typ. Capacitive Load - single output 3.3 Vout models: 4 400 F max. 5 Vout models: 2 200 F max. 12 Vout models: 1 000 F max. 15 Vout models: 820 F max. 24 Vout models: 330 F max. - dual output 5 / -5 Vout models: 1 200 / 1 200 F max. 12 / -12 Vout models: 520 / 520 F max. 15 / -15 Vout models: 440 / 440 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Start-up Time 5 ms typ. / 15 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 180% typ. of Iout max. Transient Response - Response Deviation 3% typ. (25% Load Step) - Response Time 500 s typ. (25% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment Designed for EN 62368-1 (no certification) All specifications valid at nominal voltage, resistive full load and +25C after warm-up time, unless otherwise stated. Page 2 / 4 www.tracopower.com December 10, 2021